912 research outputs found
Uniaxial and biaxial tensioning effects on thin membrane materials
Thin laminated membranes are being considered for various surface applications on future large space structural systems. Some of the thin membranes would be stretched across or between structural members with the requirement that the membrane be maintained within specified limits of smoothness which would be dictated by the particular applications such as antenna reflector requirements. The multiaxial tensile force required to maintain the smoothness in the membrane needs to be determined for use in the structure design. Therefore, several types of thicknesses of thin membrane materials have been subjected to varied levels of uniaxial and biaxial tensile loads. During the biaxial tests, deviations of the material surface smoothness were measured by a noncontacting capacitance probe. Basic materials consisted of composites of vacuum deposited aluminum on Mylar and Kapton ranging in thickness from 0.00025 in (0.000635 cm) to 0.002 in (0.00508 cm). Some of the material was reinforced with Kevlar and Nomex scrim. The uniaxial tests determined the material elongation and tensile forces up to ultimate conditions. Biaxial tests indicated that a relatively smooth material surface could be achieved with tensile force of approximately 1 to 15 Newtons per centimeter, depending upon the material thickness and/or reinforcement
Electrostatic forming and testing of polymer films on a 16-foot diameter test fixture
The large space systems technology program investigated different forms of large, lightweight, deployable structures which could be carried on the Space Shuttle. Different forms and concepts of antennas as a type of large space system were investigated. The electrostatically controlled membrane reflector made of metallized material concept was chosen. The concept is a good candidate for creating an antenna with high surface quality and has the ability to be packaged and deployed from the Shuttle with a significant reduction in weight compared to other antenna types
Determination of shuttle orbiter center of gravity from flight measurements
Flight measurements of pitch, yaw, and roll rates and the resultant rotationally induced linear accelerations during three orbital maneuvers on Shuttle mission space transportation system (STS) 61-C were used to calculate the actual orbiter center-of-gravity location. The calculation technique reduces error due to lack of absolute calibration of the accelerometer measurements and compensates for accelerometer temperature bias and for the effects of gravity gradient. Accuracy of the technique was found to be limited by the nonrandom and asymmetrical distribution of orbiter structural vibration at the accelerometer mounting location. Fourier analysis of the vibration was performed to obtain the power spectral density profiles which show magnitudes in excess of 10(exp 4) ug (sup 2)/Hz for the actual vibration and over 500 ug (sup 2)/Hz for the filtered accelerometer measurements. The data from this analysis provide a characterization of the Shuttle acceleration environment which may be useful in future studies related to accelerometer system application and zero-g investigations or processes
Sextupole correction magnets for the Large Hadron Collider
About 2500 superconducting sextupole corrector magnets (MCS) are needed for the Large Hadron Collider (LHC) at CERN to compensate persistent current sextupole fields of the main dipoles. The MCS is a cold bore magnet with iron yoke. The coils are made from a NbTi conductor, which is cooled to 1.9 K. In the original CERN design 6 individual sub-coils, made from a monolithic composite conductor, are assembled and spliced together to form the sextupole. The coils are individually wound around precision-machined central islands and stabilized with matching saddle pieces at both ends. The Advanced Magnet Lab, Inc. (AML) has produced an alternative design, which gives improved performance and reliability at reduced manufacturing cost. In the AML design, the magnet consists of three splice-free sub-coils, which are placed with an automated winding process into pockets of prefabricated G-11 support cylinders. Any assembly process of sub-coils with potential misalignment is eliminated. The AML magnet uses a Kapton-wrapped mini-cable, which allows helium penetration into the vicinity of the conductor, increasing its cryogenic stability. Eliminating all internal splices from the magnet significantly reduces heat loads and the risk of magnet failure during operation. A tested prototype reached the critical current limit of the conductor in the first quench. (3 refs)
Update to the Vitamin C, Thiamine and Steroids in Sepsis (VICTAS) protocol: statistical analysis plan for a prospective, multicenter, double-blind, adaptive sample size, randomized, placebo-controlled, clinical trial.
BACKGROUND: Observational research suggests that combined therapy with Vitamin C, thiamine and hydrocortisone may reduce mortality in patients with septic shock.
METHODS AND DESIGN: The Vitamin C, Thiamine and Steroids in Sepsis (VICTAS) trial is a multicenter, double-blind, adaptive sample size, randomized, placebo-controlled trial designed to test the efficacy of combination therapy with vitamin C (1.5 g), thiamine (100 mg), and hydrocortisone (50 mg) given every 6 h for up to 16 doses in patients with respiratory or circulatory dysfunction (or both) resulting from sepsis. The primary outcome is ventilator- and vasopressor-free days with mortality as the key secondary outcome. Recruitment began in August 2018 and is ongoing; 501 participants have been enrolled to date, with a planned maximum sample size of 2000. The Data and Safety Monitoring Board reviewed interim results at N = 200, 300, 400 and 500, and has recommended continuing recruitment. The next interim analysis will occur when N = 1000. This update presents the statistical analysis plan. Specifically, we provide definitions for key treatment and outcome variables, and for intent-to-treat, per-protocol, and safety analysis datasets. We describe the planned descriptive analyses, the main analysis of the primary end point, our approach to secondary and exploratory analyses, and handling of missing data. Our goal is to provide enough detail that our approach could be replicated by an independent study group, thereby enhancing the transparency of the study.
TRIAL REGISTRATION: ClinicalTrials.gov, NCT03509350. Registered on 26 April 2018
Branching Fractions of tau Leptons to Three Charged Hadrons
From electron-positron collision data collected with the CLEO detector
operating at CESR near \sqrt{s}=10.6 GeV, improved measurements of the
branching fractions for tau decays into three explicitly identified hadrons and
a neutrino are presented as {\cal
B}(\tau^-\to\pi^-\pi^+\pi^-\nu_\tau)=(9.13\pm0.05\pm0.46)%, {\cal B}(\tau^-\to
K^-\pi^+\pi^-\nu_\tau)=(3.84\pm0.14\pm0.38)\times10^{-3}, {\cal B}(\tau^-\to
K^-K^+\pi^-\nu_\tau)=(1.55\pm0.06\pm0.09)\times10^{-3}, and {\cal B}(\tau^-\to
K^-K^+K^-\nu_\tau)<3.7\times10^{-5} at 90% C.L., where the uncertainties are
statistical and systematic, respectively.Comment: 10 pages postscript, also available through
http://w4.lns.cornell.edu/public/CLNS, to appear in Phys. Rev. Let
Improved Measurement of the Form Factors in the Decay Lambda_c^+ --> Lambda e^+ nu_e
Using the CLEO detector at the Cornell Electron Storage Ring, we have studied
the distribution of kinematic variables in the decay Lambda_c^+ -> Lambda e^+
nu_e. By performing a four-dimensional maximum likelihood fit, we determine the
form factor ratio, R = f_2/f_1 = -0.31 +/- 0.05(stat) +/- 0.04(syst), the pole
mass, M_{pole} = (2.21 +/- 0.08(stat) +/- 0.14(syst)) GeV/c^2, and the decay
asymmetry parameter of the Lambda_c, alpha_{Lambda_c} = -0.86 +/- 0.03(stat)
+/- 0.02(syst), for = 0.67 (GeV/c^2)^2. We compare the angular
distributions of the Lambda_c^+ and Lambda_c^- and find no evidence for
CP-violation: A_{Lambda_c} = (alpha_{Lambda_c^+} + alpha_{Lambda_c^-})/
(alpha_{Lambda_c^+} - alpha_{Lambda_c^-}) = 0.00 +/- 0.03(stat) +/- 0.01(syst)
+/- 0.02, where the third error is from the uncertainty in the world average of
the CP-violating parameter, A_{Lambda}, for Lambda -> p pi^-.Comment: 8 pages postscript,also available through
http://www.lns.cornell.edu/public/CLNS/2004/, submitted to PR
Study of 3-prong Hadronic Decays with Charged Kaons
Using a sample of 4.7/fb integrated luminosity accumulated with the CLEO-II
detector at the Cornell Electron Storage Ring (CESR), we have measured the
branching fractions of the tau lepton into and relative to and relative to . The relative branching fractions are: (5.16+-0.20+-0.50)*,
(1.52+-0.14+-0.29)*, (2.54+-0.44+-0.39)* and at 95%
C.L., respectively. Coupled with additional experimental information, we use
our results to extract information on the structure of three-prong tau decays
to charged kaons.Comment: 16 pages postscript file also available through
http://w4.lns.cornell.edu/public/CLN
First Observation of barB0 to D*0 pi+pi+pi-pi- Decays
We report on the observation of B0bar -> D*0 pi+ pi+ pi- pi- decays. The
branching ratio is (0.30 +/- 0.07 +/- 0.06)%. Interest in this particular mode
was sparked by Ligeti, Luke and Wise who propose it as a way to check the
validity of factorization tests in B0bar -> D*+ pi+ pi- pi- pi0 decays.Comment: 11 pages postscript, also available through
http://w4.lns.cornell.edu/public/CLNS, Version to appear in Phys. Rev.
- …