8,168 research outputs found
Magnetism in meteorites
An overview is presented of magnetism in meteorites. A glossary of magnetism terminology followed by discussion of the various techniques used for magnetism studies in meteorites are included. The generalized results from use of these techniques by workers in the field are described. A brief critical analysis is offered
Solar System Processes Underlying Planetary Formation, Geodynamics, and the Georeactor
Only three processes, operant during the formation of the Solar System, are
responsible for the diversity of matter in the Solar System and are directly
responsible for planetary internal-structures, including planetocentric nuclear
fission reactors, and for dynamical processes, including and especially,
geodynamics. These processes are: (i) Low-pressure, low-temperature
condensation from solar matter in the remote reaches of the Solar System or in
the interstellar medium; (ii) High-pressure, high-temperature condensation from
solar matter associated with planetary-formation by raining out from the
interiors of giant-gaseous protoplanets, and; (iii) Stripping of the primordial
volatile components from the inner portion of the Solar System by super-intense
solar wind associated with T-Tauri phase mass-ejections, presumably during the
thermonuclear ignition of the Sun. As described herein, these processes lead
logically, in a causally related manner, to a coherent vision of planetary
formation with profound implications including, but not limited to, (a) Earth
formation as a giant gaseous Jupiter-like planet with vast amounts of stored
energy of protoplanetary compression in its rock-plus-alloy kernel; (b) Removal
of approximately 300 Earth-masses of primordial gases from the Earth, which
began Earth's decompression process, making available the stored energy of
protoplanetary compression for driving geodynamic processes, which I have
described by the new whole-Earth decompression dynamics and which is
responsible for emplacing heat at the mantle-crust-interface at the base of the
crust through the process I have described, called mantle decompression
thermal-tsunami; and, (c)Uranium accumulations at the planetary centers capable
of self-sustained nuclear fission chain reactions.Comment: Invited paper for the Special Issue of Earth, Moon and Planets
entitled Neutrino Geophysics Added final corrections for publicatio
Thermomagnetic analysis of meteorites. 3: C3 and C4 chondrites
Thermomagnetic analysis on all of the C3 and C4 chondrites, conducted under conditions of controlled oxygen fugacity, indicates the presence of a thermally unstable component in at least 5 of the C3 chondrites which upon heating results in magnetite production. This unstable component is most likely troilite (FeS). The presence of the unstable substance may affect the estimation of paleointensities in meteorites which contain it. Our results indicate that Grosnaja, Ornans, Kainsaz, Felix, and Warrenton are likely to be less complicated for paleointensity determinations than the other C3 chondrites. Both C4 chondrites should lead to reliable results
Thermomagnetic analysis of meterorites. 4: Ureilites
Samples of all available ureilites have been analyzed thermomagnetically. For three of the six (Dyalpur, Goalpara and Havero) evidence was found for only low-nickel metallic-iron as the magnetic component and the (saturation magnetization vs, temperature) curves were reversible. In the Novo Urei ureilite, magnetite in addition to low-nickel metallic-iron was indicated and again the Js-T curve was reversible. For the two badly weathered ureilites, Dingo Pup Donga and North Haig, indication was also found that both initial magnetite and low-nickel metallic-iron were present. However, the Js-T curves were somewhat irreversible and the final saturation magnetization was 20% and 50% greater than initially for North Haig and Dingo Pup Donga, respectively. This behavior is interpreted to be the result of magnetite production from a secondary iron oxide during the experiment
Thermomagnetic analysis of meteorites, 2: C2 chondrites
Samples of all eighteen of the known C2 chondrites were analyzed thermomagnetically. For eleven of these, initial Fe3O4 content is low(generally 1%) and the J sub s-T curves are irreversible. The heating curves show variable and erratic behavior, whereas the cooling curves appear to be that of Fe3O4. The saturation moment after cooling is greater (up to 10 times larger) than it is initially. This behavior is interpreted to be the result of the production of magnetite from a thermally unstable phase--apparently FeS. Four of the remaining 7 C2 chondrites contain Fe3O4 as the only significant magnetic phase: initial magnetite contents range from 4 to 13 percent. The remaining three C2 chondrites contain iron or nickel-iron in addition to Fe3O4. These seven C2 chondrites show little evidence of the breakdown of a thermally unstable phase
The Global Competitiveness of the North American Livestock Industry
Livestock Production/Industries, F14, Q17,
Intercomparison of field measurements of nitrous acid (HONO) during the SHARP campaign
Because of the importance of HONO as a radical reservoir, consistent and accurate measurements of its concentration are needed. As part of SHARP (Study of Houston Atmospheric Radical Precursors), time series of HONO were obtained by six different measurement techniques on the roof of the Moody Tower at the University of Houston. Techniques used were long path differential optical absorption spectroscopy (DOAS), stripping coil-visible absorption photometry (SC-AP), long path absorption photometry (LOPAP® ), mist chamber/ion chromatography (MC-IC), quantum cascade-tunable infrared laser differential absorption spectroscopy (QC-TILDAS), and ion drift-chemical ionization mass spectrometry (ID-CIMS). Various combinations of techniques were in operation from 15 April through 31 May 2009. All instruments recorded a similar diurnal pattern of HONO concentrations with higher median and mean values during the night than during the day. Highest values were observed in the final 2 weeks of the campaign. Inlets for the MC-IC, SC-AP, and QC-TILDAS were collocated and agreed most closely with each other based on several measures. Largest differences between pairs of measurements were evident during the day for concentrations ~100 parts per trillion (ppt). Above ~ 200 ppt, concentrations from the SC-AP, MC-IC, and QC-TILDAS converged to within about 20%, with slightly larger discrepancies when DOAS was considered. During the first 2 weeks, HONO measured by ID-CIMS agreed with these techniques, but ID-CIMS reported higher values during the afternoon and evening of the final 4 weeks, possibly from interference from unknown sources. A number of factors, including building related sources, likely affected measured concentrations
Atmospheric CH4 and N2O measurements near Greater Houston area landfills using a QCL-based QEPAS sensor system during DISCOVER-AQ 2013
A quartz-enhanced photoacoustic absorption spectroscopy (QEPAS)-based gas sensor was developed for methane (CH4) and nitrous-oxide (N 2O) detection. The QEPAS-based sensor was installed in a mobile laboratory operated by Aerodyne Research, Inc. to perform atmospheric CH 4 and N2O detection around two urban waste-disposal sites located in the northeastern part of the Greater Houston area, during DISCOVER-AQ, a NASA Earth Venture during September 2013. A continuous wave, thermoelectrically cooled, 158 mW distributed feedback quantum cascade laser emitting at 7.83 μm was used as the excitation source in the QEPAS gas sensor system. Compared to typical ambient atmospheric mixing ratios of CH4 and N2O of 1.8 ppmv and 323 ppbv, respectively, significant increases in mixing ratios were observed when the mobile laboratory was circling two waste-disposal sites in Harris County and when waste disposal trucks were encountered. © 2014 Optical Society of America
Recommended from our members
Inspection of contaminated hot cell ductwork
Radiation Sterilization, Incorporated (RSI), of Dekalb County, Georgia, has used Cesium-137 radiation sources for sterilization of medical instruments and other commercial items. The cesium is contained in welded stainless steel capsules. One of these capsules has leaked, allowing the cesium to escape and to contaminate the internals of the sterilization cells including the cell ventilation ductwork penetrating the thick concrete cell roof. This ductwork requires decontamination prior to release of the facility to resume sterilization activities. Due to the small size (20-in. {times} 24-in. cross section) and the long runs embedded in the cell roof, it was determined that remote visual inspection and preliminary radiation mapping of this ductwork was necessary. This report covers the inspection effort and evaluation of the results. 23 figs., 3 tabs
Effect of aerosols and NO<sub>2</sub> concentration on ultraviolet actinic flux near Mexico City during MILAGRO: measurements and model calculations
Urban air pollution absorbs and scatters solar ultraviolet (UV) radiation, and thus has a potentially large effect on tropospheric photochemical rates. We present the first detailed comparison between actinic fluxes (AF) in the wavelength range 330–420 nm measured in highly polluted conditions and simulated with the Tropospheric Ultraviolet-Visible (TUV) model. Measurements were made during the MILAGRO campaign near Mexico City in March 2006, at a ground-based station near Mexico City (the T1 supersite) and from the NSF/NCAR C-130 aircraft. At the surface, measured AF values are typically smaller than the model by up to 25% in the morning, 10% at noon, and 40% in the afternoon, for pollution-free and cloud-free conditions. When measurements of PBL height, NO<sub>2</sub> concentration and aerosols optical properties are included in the model, the agreement improves to within ±10% in the morning and afternoon, and ±3% at noon. Based on daily averages, aerosols account for 68% and NO<sub>2</sub> for 25% of AF reductions observed at the surface. Several overpasses from the C-130 aircraft provided the opportunity to examine the AF perturbations aloft, and also show better agreement with the model when aerosol and NO<sub>2</sub> effects are included above and below the flight altitude. TUV model simulations show that the vertical structure of the actinic flux is sensitive to the choice of the aerosol single scattering albedo (SSA) at UV wavelengths. Typically, aerosols enhance AF above the PBL and reduce AF near the surface. However, for highly scattering aerosols (SSA > 0.95), enhancements can penetrate well into the PBL, while for strongly absorbing aerosols (SSA < 0.6) reductions in AF are computed in the free troposphere as well as in the PBL. Additional measurements of the SSA at these wavelengths are needed to better constrain the effect of aerosols on the vertical structure of the AF
- …