Design of Semi-active Magnetorheological Valve with Non-magnetic Bypass
The paper presents a methodology of designof a semi-active magnetorheological (MR) valve. Themethodology was composed of the non-Newtonian fluid flowanalysis and FEM analysis of a magnetic circuit. Based onthe present methodology a MR valve was designed. The MRvalve achieves damping force 1600 N at a velocity of 0.15m/s. The time response was determined to 6 ms