53 research outputs found
Monte Carlo calibration of the SMM gamma ray spectrometer for high energy gamma rays and neutrons
The Gamma Ray Spectrometer (GRS) on the Solar Maximum Mission spacecraft was primarily designed and calibrated for nuclear gamma ray line measurements, but also has a high energy mode which allows the detection of gamma rays at energies above 10 MeV and solar neutrons above 20 MeV. The GRS response has been extrapolated until now for high energy gamma rays from an early design study employing Monte Carlo calculations. The response to 50 to 600 MeV solar neutrons was estimated from a simple model which did not consider secondary charged particles escaping into the veto shields. In view of numerous detections by the GRS of solar flares emitting high energy gamma rays, including at least two emitting directly detectable neutrons, the calibration of the high energy mode in the flight model has been recalculated by the use of more sophisticated Monte Carlo computer codes. New results presented show that the GRS response to gamma rays above 20 MeV and to neutrons above 100 MeV is significantly lower than the earlier estimates
Time extended production of neutrons during a solar flare
The most energetic neutral emissions expected from solar flares are gamma rays (10 MeV) from relativistic primary and secondary electron bremsstrahlung,from approx 0 meson decay, and from neutrons ( 50 MeV). Bremsstrahlung photon energies extend to that of the highest energy electron present, but the shape of the pi sup 0 gamma ray spectrum, peaking at 69 MeV, does not depend strongly on the proton spectrum above threshold, which is approx. 292 MeV for meson production on protons. The highest energy neutrons observed indicate directly the highest energy ions which interact at the Sun, and the presence or absence of anergy cutoff in the acceleration process. The high-energy proton spectrum shape can be determined from the neutron spectrum
Confirmation of Two Cyclotron Lines in Vela X-1
We present pulse phase-resolved X-ray spectra of the high mass X-ray binary
Vela X-1 using the Rossi X-ray Timing Explorer. We observed Vela X-1 in 1998
and 2000 with a total observation time of ~90 ksec. We find an absorption
feature at 23.3 +1.3 -0.6 kev in the main pulse, that we interpret as the
fundamental cyclotron resonant scattering feature (CRSF). The feature is
deepest in the rise of the main pulse where it has a width of 7.6 +4.4 -2.2 kev
and an optical depth of 0.33 +0.06 -0.13. This CRSF is also clearly detected in
the secondary pulse, but it is far less significant or undetected during the
pulse minima. We conclude that the well known CRSF at 50.9 +0.6 -0.7 kev, which
is clearly visible even in phase-averaged spectra, is the first harmonic and
not the fundamental. Thus we infer a magnetic field strength of B=2.6 x 10^12
G.Comment: 12 pages, LaTeX, 15 Figures, accepted by A&
The European Photon Imaging Camera on XMM-Newton: The MOS Cameras
The EPIC focal plane imaging spectrometers on XMM-Newton use CCDs to record
the images and spectra of celestial X-ray sources focused by the three X-ray
mirrors. There is one camera at the focus of each mirror; two of the cameras
contain seven MOS CCDs, while the third uses twelve PN CCDs, defining a
circular field of view of 30 arcmin diameter in each case. The CCDs were
specially developed for EPIC, and combine high quality imaging with spectral
resolution close to the Fano limit. A filter wheel carrying three kinds of
X-ray transparent light blocking filter, a fully closed, and a fully open
position, is fitted to each EPIC instrument. The CCDs are cooled passively and
are under full closed loop thermal control. A radio-active source is fitted for
internal calibration. Data are processed on-board to save telemetry by removing
cosmic ray tracks, and generating X-ray event files; a variety of different
instrument modes are available to increase the dynamic range of the instrument
and to enable fast timing. The instruments were calibrated using laboratory
X-ray beams, and synchrotron generated monochromatic X-ray beams before launch;
in-orbit calibration makes use of a variety of celestial X-ray targets. The
current calibration is better than 10% over the entire energy range of 0.2 to
10 keV. All three instruments survived launch and are performing nominally in
orbit. In particular full field-of-view coverage is available, all electronic
modes work, and the energy resolution is close to pre-launch values. Radiation
damage is well within pre-launch predictions and does not yet impact on the
energy resolution. The scientific results from EPIC amply fulfil pre-launch
expectations.Comment: 9 pages, 11 figures, accepted for publication in the A&A Special
Issue on XMM-Newto
On the performance of optical filters for the XMM focal plane CCD-camera EPIC
Optical filters have been developed for the X-ray astronomy project XMM (X-ray Multi Mirror Mission) [1] of ESA, where specific CCDs will serve as focal plane cameras on board the observatory. These detectors are sensitive from the X-ray to the NIR (near infrared) spectral region. For observations in X-ray astronomy an optical filter must be placed in front of the CCD, suppressing visible and UV (ultraviolet) radiation of stars by more than 6 orders of magnitude while being highly transparent at photon energies above 100 eV. The flight model filter is designed to have an effective area of 73 mm diameter without making use of a supporting grid. Efforts have been made to utilize plastic foils to tailor filters meeting these specific requirements. It was found, that a typical filter could be composed, e.g., of a polypropylene foil of 20 μg/cm2 thickness serving as a carrier, coated with metallic films of Al or Al and Sn of about 20–25 μg/cm2 thickness. Other possible carriers are polycarbonate (Lexan, Macrolon) and poly-para-xylylene (Parylene N) films of similar thicknesses. The preparation and characterization of these three types of carrier foils as well as of two sample filters is described, including mechanical tests as well as optical transmission measurements in the photon energy range from 1 eV to 2 keV
- …