592 research outputs found

    Corrosion and corrosion prevention in gas turbines

    Get PDF
    The conditions governing the corrosion behavior in gas turbines are surveyed. Factors such as temperature, relative humidity, the presence of sulfur and nitrogen dioxide, and fuel quality are discussed. Electromechanical corrosion at relatively low temperature in compressors; oxidation; and hot corrosion (sulfidation) at high temperature in turbines are considered. Corrosion prevention by washing and rinsing, fueld additives, and corrosion resistant materials and coatings are reviewed

    Surface plasmon resonance immunosensors: sensitivity considerations

    Get PDF
    Some aspects of improving surface plasmon resonance response in immunosensing applications are considered. Both from calculations and experiments, it was found that maximum sensitivity is obtained for a silver layer about 55 nm thick in direct contact with the species to be quantified. Application of an intermediate layer with high permittivity can be useful in suppressing background responses. Experimentally, a protein surface-coverage fraction of ca. 0.1 could be measured, corresponding to ca. 10āˆ’10 mol1āˆ’1 antibody

    Features of the Structure, Development, and Activity of the Zebrafish Noradrenergic System Explored in New CRISPR Transgenic Lines

    Get PDF
    The noradrenergic (NA) system of vertebrates is implicated in learning, memory, arousal, and neuroinflammatory responses, but is difficult to access experimentally. Small and optically transparent, larval zebrafish offer the prospect of exploration of NA structure and function in an intact animal. We made multiple transgenic zebrafish lines using the CRISPR/Cas9 system to insert fluorescent reporters upstream of slc6a2, the norepinephrine transporter gene. These lines faithfully express reporters in NA cell populations, including the locus coeruleus (LC), which contains only about 14 total neurons. We used the lines in combination with twoā€photon microscopy to explore the structure and projections of the NA system in the context of the columnar organization of cell types in the zebrafish hindbrain. We found robust alignment of NA projections with glutamatergic neurotransmitter stripes in some hindbrain segments, suggesting orderly relations to neuronal cell types early in life. We also quantified neurite density in the rostral spinal cord in individual larvae with as much as 100% difference in the number of LC neurons, and found no correlation between neuronal number in the LC and projection density in the rostral spinal cord. Finally, using light sheet microscopy, we performed bilateral calcium imaging of the entire LC. We found that largeā€amplitude calcium responses were evident in all LC neurons and showed bilateral synchrony, whereas smallā€amplitude events were more likely to show interhemispheric asynchrony, supporting the potential for targeted LC neuromodulation. Our observations and new transgenic lines set the stage for a deeper understanding of the NA system

    Pancreatic ductal adenocarcinoma and chronic pancreatitis may be diagnosed by exhaled-breath profiles:a multicenter pilot study

    Get PDF
    Background: The diagnosis of pancreatic adenocarcinoma and chronic pancreatitis often rely on expensive and invasive diagnostic approaches, which are not always discriminative since patients with chronic pancreatitis and pancreatic adenocarcinoma may present with similar symptoms. Volatile organic compounds (VOCs) in expired breath, could be used as a non-invasive diagnostic biological marker for detection of pancreatic pathology. Detection and discrimination of pancreatic pathology with an electronic nose has not yet been reported. Purpose: The objective of this pilot study was to determine the diagnostic potential of an electronic nose to identify pancreatic adenocarcinoma and chronic pancreatitis by analyzing volatile organic compoundg (VOC) profiles in exhaled air. Patients and methods: In a multicenter study, the exhaled air of 56 chronic pancreatitis patients, 29 pancreatic adenocarcinoma patients, and 74 disease controls were analyzed using an electronic nose based on 3 metal oxide sensors (MOS). The measurements were evaluated utilizing an artificial neural network. Results: VOC profiles of chronic pancreatitis patients could be discriminated from disease controls with an accuracy of 0.87 (AUC 0.95, sensitivity 80%, specificity 92%). Also, VOC profiles of patients with pancreatic adenocarcinoma differed from disease controls with an accuracy of 0.83 (AUC 0.87, sensitivity 83%, specificity 82%). Discrimination between chronic pancreatitis and pancreatic adenocarcinoma showed an accuracy of 0.75 (AUC 0.83, sensitivity 83%, specificity 71%). Conclusion: An electronic nose may be a valuable diagnostic tool in diagnosis of pancreatic adenocarcinoma and chronic pancreatitis. The current study shows the potential of an electronic nose for discriminating between chronic pancreatitis, pancreatic adenocarcinoma and healthy controls. The results from this proof-of-concept study warrant external validation in larger cohorts

    Twenty-Four Hour Tonometry in Patients Suspected of Chronic Gastrointestinal Ischemia

    Get PDF
    Background and aims: Gastrointestinal tonometry is currently the only clinical diagnostic test that enables identification of symptomatic chronic gastrointestinal ischemia. Gastric exercise tonometry has proven its value for detection of ischemia in this patients group, but has its disadvantages. Earlier studies with postprandial tonometry gave unreliable results. In this study we challenged (again) the use of postprandial tonometry in patients suspected of gastrointestinal ischemia. Methods: Patients suspected for chronic gastrointestinal ischemia had standard diagnostic work up, including gastric exercise tonometry and 24-h tonometry using standard meals. Results: Thirty-three patients were enrolled in the study. Chronic gastrointestinal ischemia was diagnosed in 17 (52%) patients. The 24-h tonometry correctly predicted the presence of ischemia in 13/17 patients, and absence of ischemia in 15/16 patients. Conclusions: The use of 24-h tonometry after meals in patients suspected of gastrointestinal ischemia seems feasible, with promising accuracy for the detection of ischemia

    Tool catalogue frame-based information tools

    Get PDF
    In the perception, knowledge production and policymaking on complex issues (ā€˜wicked problemsā€™), such as climate change, frames and framing play an important but often hidden role. Frames relate to oneā€™s ā€˜schemas of interpretationā€™; the conceptual images, values, starting points, and mental models that one may have of an issue. This can include, for instance, oneā€™s problem definition, perceptions of the cause-effect relationships in an issue, oneā€™s primary goals, perception of oneā€™s and othersā€™ roles and responsibilities relating to the issue, and views on suitable strategies and interaction with (other) stakeholders (cf. Dewulf et al., 2005)

    Covered stents versus Bare-metal stents in c hronic atherosclerotic Gastrointestinal Ischemia (CoBaGI):study protocol for a randomized controlled trial

    Get PDF
    Background: Chronic mesenteric ischemia (CMI) is the result of insufficient blood supply to the gastrointestinal tract and is caused by atherosclerotic stenosis of one or more mesenteric arteries in &gt; 90% of cases. Revascularization therapy is indicated in patients with a diagnosis of atherosclerotic CMI to relieve symptoms and to prevent acute-on-chronic mesenteric ischemia, which is associated with high morbidity and mortality. Endovascular therapy has rapidly evolved and has replaced surgery as the first choice of treatment in CMI. Bare-metal stents (BMS) are standard care currently, although retrospective studies suggested significantly higher patency rates for covered stents (CS). The Covered stents versus Bare-metal stents in chronic atherosclerotic Gastrointestinal Ischemia (CoBaGI) trial is designed to prospectively assess the patency of CS versus BMS in patients with atherosclerotic CMI.Methods/design: The CoBaGI trial is a randomized controlled, parallel-group, patient-and investigator-blinded, superiority, multicenter trial conducted in six centers of the Dutch Mesenteric Ischemia Study group (DMIS). Eighty-four patients with a consensus diagnosis of atherosclerotic CMI are 1:1 randomized to either a balloon-expandable BMS (Palmaz Blue with rapid-exchange delivery system, Cordis Corporation, Bridgewater, NJ, USA) or a balloon-expandable CS (Advanta V12 over-the-wire, Atrium Maquet Getinge Group, Hudson, NH, USA). The primary endpoint is the primary stent-patency rate at 24 months assessed with CT angiography. Secondary endpoints are primary stent patency at 6 and 12 months and secondary patency rates, freedom from restenosis, freedom from symptom recurrence, freedom from re-intervention, quality of life according the EQ-5D-5 L and SF-36 and cost-effectiveness at 6, 12 and 24 months.Discussion: The CoBaGI trial is designed to assess the patency rates of CS versus BMS in patients treated for CMI caused by atherosclerotic mesenteric stenosis. Furthermore, the CoBaGI trial should provide insights in the quality of life of these patients before and after stenting and its cost-effectiveness. The CoBaGI trial is the first randomized controlled trial performed in CMI caused by atherosclerotic mesenteric artery stenosis.</p

    Dosimetric benefits and preclinical performance of steerable needles in HDR prostate brachytherapy

    Get PDF
    Prostate cancer patients with an enlarged prostate and/or excessive pubic arch interference (PAI) are generally considered non-eligible for high-dose-rate (HDR) brachytherapy (BT). Steerable needles have been developed to make these patients eligible again. This study aims to validate the dosimetric impact and performance of steerable needles within the conventional clinical setting. HDR BT treatment plans were generated, needle implantations were performed in a prostate phantom, with prostate volume &gt; 55 cm3 and excessive PAI of 10 mm, and pre- and post-implant dosimetry were compared considering the dosimetric constraints: prostate V100 &gt; 95 % (13.50 Gy), urethra D0.1cm3 &lt; 115 % (15.53 Gy) and rectum D1cm3 &lt; 75 % (10.13 Gy). The inclusion of steerable needles resulted in a notable enhancement of the dose distribution and prostate V100 compared to treatment plans exclusively employing rigid needles to address PAI. Furthermore, the steerable needle plan demonstrated better agreement between pre- and post-implant dosimetry (prostate V100: 96.24 % vs. 93.74 %) compared to the rigid needle plans (79.13 % vs. 72.86 % and 87.70 % vs. 81.76 %), with no major changes in the clinical workflow and no changes in the clinical set-up. The steerable needle approach allows for more flexibility in needle positioning, ensuring a highly conformal dose distribution, and hence, HDR BT is a feasible treatment option again for prostate cancer patients with an enlarged prostate and/or excessive PAI.</p
    • ā€¦
    corecore