16 research outputs found

    On bimodular spaces

    No full text
    The article contains no abstrac

    Badania strukturalne oraz wyznaczanie charakterystyk prwo-napięciowych dla taśm htsc 2GSF12050

    No full text
    Investigations of a state-of-the art high-temperature ceramic superconducting tape of SF 12050 series are presented. The study focuses on current and voltage characteristics, examination of microstructure and analysis of chemical composition in superconducting tapes of SF series. In order to measure current parameters, a measuring system was designed to investigate sections of the tapes at the temperature of liquid nitrogen. The system is powered with direct current with parameters I= 0 ÷ 580A and U= 0 ÷ 8V. Measurements of critical current were taken by means of determination of the decline in voltage along the measurement section for the tape with accuracy of 1nV. Analysis of chemical composition was carried out using scanning microscope which features chemical composition microanalyser EDX. The paper presents microscope images which are a result of examination of the structures by means of light microscope and scanning microscope. The method of preparation of superconducting tapes for soldering and the method of selection of solder were also presented.W pracy zaprezentowano wyniki badań ceramicznej wysokotemperaturowej taśmy nadprzewodzacej najnowszej generacji z serii SF 12050. W artykule przedstawiono badania dotyczące wyznaczania charakterystyk prądowo-napięciowych, obserwacji mikrostruktury oraz analizy składu chemicznego taśm nadprzewodzących z serii SF. Do badań parametrow pradowych został zaprojektowany i zbudowany układ pomiarowy umożliwiający badanie odcinkow taśm w temperaturze ciekłego azotu. Układ ten jest zasilany źródłem prądu stałego o parametrach I= 0 580A oraz U= 0 8V. Pomiary prądu krytycznego sa wykonywane przez określenie spadku napięcia na odcinku pomiarowym tasmy z dokladnoscia do1 nV na odcinku pomiarowym nadprzewodnika. Analizę składu chemicznego przeprowadzono przy zastosowaniu mikroskopu skaningowego z mikro-analizatorem składu chemicznego EDX. W pracy zamieszczone zostały obrazy mikroskopowe bedace wynikiem obserwacji struktur za pomocą mikroskopu świetlnego oraz skaningowego. Przedstawiona została rownież metoda preparatyki tasmy nadprzewodzacej do lutowania oraz sposob doboru lutowia

    Prevalence of coronary heart disease risk factors and occupation

    No full text
    Obserwowany w ostatnich dwóch dziesięcioleciach wzrost występowania choroby niedokrwiennej serca w społeczeństwie spowodował zainteresowanie środowisk naukowych oraz ogółu społeczeństwa czynnikami ryzyka związanymi z tą chorobą. Szczególnie niepokojącym zjawiskiem jest obniżanie się wieku chorych, u których w przebiegu choroby niedokrwiennej serca występuje zawał serca. Zainteresowanie budzi również wpływ stylu życia oraz stresu wynikającego z wykonywanej pracy na występowanie czynników ryzyka choroby niedokrwiennej serca. W artykule przedstawiono klasyfikację czynników ryzyka choroby niedokrwiennej serca według AHA, metody oceny ryzyka sercowo-naczyniowego, oraz wyniki pracy dotyczącej występowania czynników ryzyka choroby niedokrwiennej serca w dwóch grupach zawodowych: wśród kierowników i pracowników fizycznych.The increasing prevalence of coronary hart disease (CHD), which has been observed in the past two decades, has resulted in researchers' and the general public's interest in the risk factors CHD. The decreasing age of patients with CHD complicated by myocardial infarction is particularly worrying. The influence of life-style and occupational stress on the prevalence of CHD risk factors is focused on, too. This article presents a classification of CHD risk factors and methods for cardiovascular risk assessment as well as the results of our own study on the prevalence of CHD risk factors in two professional groups: managers and blue-collar workers

    Analysis of Conditions and Organization of Work of Notebook Computer Users

    No full text
    Aim. The aim of this study was to evaluate working conditions with a notebook computer (notebook) as a potential cause of musculoskeletal disorders. Material and methods. The study had 2 stages. The first one was a questionnaire survey among 300 notebook users. The next stage was an expert analysis of 53 randomly selected workstations. The questionnaire survey included questions about the participants, their working conditions, work organization and also duration of work with a notebook. Results and conclusions. The results of the research showed that most examined operators used a notebook as a basic working tool. The most important irregularities included an unadjustable working surface, unadjustable height of the seat pan and backrest, unadjustable height and distance between the armrests and no additional ergonomic devices (external keyboard, docking station, notebook stand or footstool)

    Carpal Tunnel Syndrome in Occupational Medicine Practice

    No full text
    Work-related overload syndromes are chiefly associated with the upper limbs, where carpal tunnel syndrome (CTS) plays a leading role. This article analyses methods of diagnosing CTS, with special emphasis on those that can be used by physicians in early diagnosis of CTS in workers doing monotonous work. It also discusses occupational (e.g., assembly work, typing, playing instruments, packaging and work associated with the use of a hammer or pruning scissors) and extra-occupational factors (e.g., post-traumatic deformation of bone elements of the carpal tunnel, degenerative and inflammatory changes in tendon sheaths, connective tissue hypertrophy or formation of crystal deposits) leading to CTS; diagnostic methods (subjective symptoms, physical examination, manual provocative tests, vibration perception threshold, electrophysiological examination and imaging methods); and therapeutic and preventive management tools accessible in occupational medicine practice

    Coronary Heart Disease Risk Factors and Cardiovascular Risk in Physical Workers and Managers

    No full text
    This study aimed to assess the incidence of coronary heart disease (CHD) risk factors and cardiovascular risk in physical workers and managers in Poland. There were 232 male subjects: 123 managers (48.9 ± 11.2 years old) and 109 physical workers (37.5 ± 11.1 years old). The family history of CHD was recorded and anthropometric and biochemical indices, i.e., body mass index, visceral obesity index, blood pressure, glucose, total cholesterol, fibrinogen, HDL (high density lipoprotein), LDL (low density lipoprotein) and triglycerides were measured. Cardiovascular risk was assessed with the Systematic Coronary Risk Evaluation (SCORE) table system. The factors that turned out to be the most common in the managers were obesity, hypertension, and elevated levels of blood glucose and LDL, whereas cigarette smoking, premature CHD in the family and a high level of fibrinogen were more common in physical workers. Very high cardiovascular risk was found in 35% of managers and in 16% of physical workers

    Photoinduced Operation by Absorption of the Chalcogenide Nanocrystallite Containing Solar Cells

    No full text
    It is shown that for the solar cells containing chalcogenide nanocrystallites using external laser light, one can achieve some enhancement of the photovoltaic efficiency. Photoinduced treatment was carried out using two beams of splitted Er: glass laser operating at 1.54 μm. The light of the laser was incident at different angles and the angles between the beams also were varied. Also, the studies of nanocomposite effective structures have shown enhancement of effective nanocrystalline sizes during the laser treatment. Nanocrystallites of CuInS2 and CuZnSnS4 (CZTS) were used as chalcogenide materials. The optimization of the laser beam intensities and nanoparticle sizes were explored

    Ocena struktury oraz właściwości magnetycznych stopów amorficznych Fe73Me5Y3B19 (gdzie Me = Ti lub Nb)

    No full text
    The results of microstructure and magnetic properties studies of the amorphous Fe73Me5Y3B19 (where Me = Ti or Nb) alloys are presented The samples of the investigated alloys were produced in the form of ribbons with thickness of approximately 30 um by unidirectional cooling of the liquid material on a rotating copper wheel. Both investigated alloys, in the as-quenched state, were fully amorphous which was verified using a ‘Bruker’ X-ray diffractometer. Static hysteresis loops, measured using ‘LakeShore’ vibrating sample magnetometer (VSM), were typical as for soft magnetic ferromagnets. The Fe73Nb5Y3B19 and Fe73Ti5Y3B19 alloys were characterized by relatively high values of saturation of the magnetization (1.25 T and 1.26 T, respectively) and low coercivity field (16 A/m and 47 A/m, respectively). The core losses obtained for the investigated alloys were significantly lower than for commercially used FeSi transformer steels. Both alloys also exhibited excellent time and temperature stability of the magnetic properties (within the investigated temperature range), as confirmed by measurements of magnetic susceptibility and its disaccommodation.Celem pracy było zbadanie mikrostruktury oraz właściwości magnetycznych czteroskładnikowych stopów Fe73Me5Y3B19 (gdzie Me = Ti lub Nb) o strukturze amorficznej, otrzymanych techniką ultraszybkiego zestalania ciekłego stopu na miedzianym obracającym się bębnie. Strukturę odlanych taśm badano za pomocą dyfraktometru rentgenowskiego firmy "Bruker". Z pomiarów tych wynika, że obydwa czteroskładnikowe stopy w stanie po odlaniu były amorficzne. Statyczne pętle histerezy zmierzone przy użyciu magnetometru wibracyjnego (VSM) firmy "LeakeSchore", były typowe jak dla ferromagnetyków magnetycznie miękkich, a wytworzone stopy Fe73Nb5Y3B19 i Fe73Ti5Y3B19 cechowały się względnie wysoką magnetyzacją nasycenia (odpowiednio: 1.25 T i 1.26 T) i małym polem koercji (odpowiednio: 16 A/m i 47 A/m). Straty energii potrzebnej na jeden cykl przemagnesowania dla obydwu badanych stopów były znacznie mniejsze niż dla komercyjnie produkowanych stali transformatorowych FeSi. Wytworzone stopy wykazywały dobrą stabilność czasową oraz temperaturową właściwości magnetycznych (w wyznaczonym zakresie temperatur), któwą określono na podstawie pomiarów podatności magnetycznej i jej dezakomodacji
    corecore