942 research outputs found
Imaging and burst location with the EXIST high-energy telescope
The primary instrument of the proposed EXIST mission is a coded mask high
energy telescope (the HET), that must have a wide field of view and extremely
good sensitivity. It will be crucial to minimize systematic errors so that even
for very long total integration times the imaging performance is close to the
statistical photon limit. There is also a requirement to be able to reconstruct
images on-board in near real time in order to detect and localize gamma-ray
bursts. This must be done while the spacecraft is scanning the sky. The
scanning provides all-sky coverage and is key to reducing systematic errors.
The on-board computational problem is made even more challenging for EXIST by
the very large number of detector pixels. Numerous alternative designs for the
HET have been evaluated. The baseline concept adopted depends on a unique coded
mask with two spatial scales. Monte Carlo simulations and analytic analysis
techniques have been used to demonstrate the capabilities of the design and of
the proposed two-step burst localization procedure
Chandra Observations of the Optically Dark GRB030528
The X-ray-rich GRB030528 was detected by the HETE satellite and its
localization was rapidly disseminated. However, early optical observations
failed to detect a counterpart source. In a 2-epoch ToO observation with
Chandra, we discovered a fading X-ray source likely counterpart to GRB030528.
The source brightness was typical of X-ray afterglows observed at similar
epochs. Other observers detected an IR source at a location consistent with the
X-ray source. The X-ray spectrum is not consistent with a large absorbing
column.Comment: 4 pages, 1 figures, to appear in Santa Fe GRB Conference Proceedings,
200
Previously Claimed(/Unclaimed) X-ray Emission Lines in High Resolution Afterglow Spectra
We review the significance determination for emission lines in the Chandra
HETGS spectrum for GRB020813, and we report on a search for additional lines in
high resolution Chandra spectra. No previously unclaimed features are found. We
also discuss the significance of lines sets reportedly discovered using XMM
data for GRB011211 and GRB030227. We find that these features are likely of
modest, though not negligible, significance.Comment: 4 pages, 1 figures, to appear in Santa Fe GRB Conference Proceedings,
200
Optical and X-ray Observations of the Afterglow to XRF030723
The X-ray-flash XRF030723 was detected by the HETE satellite and rapidly
disseminated, allowing for an optical transient to be detected ~1 day after the
burst. We discuss observations in the optical with Magellan, which confirmed
the fade of the optical transient. In a 2-epoch ToO observation with Chandra,
we discovered a fading X-ray source spatially coincident with the optical
transient. We present spectral fits to the X-ray data. We also discuss the
possibility that the source underwent a rebrightening in the X-rays, as was
observed in the optical. We find that the significance of a possible
rebrightening is very low (~1 sigma).Comment: 4 pages, 2 figures, to appear in Santa Fe GRB Conference Proceedings,
200
Recommended from our members
Public Release of a One Dimensional Version of the Photon Clean Method (PCM1D)
We announce the public release of a one dimensional version of the Photon Clean Method (PCM1D). This code is in the general class of 'inverse Monte Carlo' methods and is specifically designed to interoperate with the public analysis tools available from the Chandra Science Center and the HEASARC. The tool produces models of event based data on a photon by photon basis. The instrument models are based on the standard ARF and RMF fits files. The resulting models have a high number of degrees of freedom of order the number of photons detected providing an alternative analysis compared to the usual method of fitting models with only a few parameters. The original work on this method is described in ADASS 1996 (Jernigan and Vezie)
Recommended from our members
Final Report of B548129: Spectral Analysis of Soft X-Ray Data from NSTX
We present a summary of work performed under subcontract B548129 'Spectral Analysis of Soft X-Ray Data from NSTX'. This summary is comprised of papers and poster presentations prepared under this subcontract. The X-ray and Extreme Ultraviolet Spectrometer (XEUS) has been used to monitor the line emission from various impurity ions on NSTX, in particular the K-shell emission of helium-like and hydrogen-like B, C, N, and O. While C VI typically dominates the spectrum, unusually strong emission from N VII has been observed in multiple discharges during the past run campaign. In this case, the nitrogen concentration can exceed that of carbon by an order of magnitude. Time-dependent measurements show that the nitrogen concentration builds up over the course of the discharge and coincides with a build up of boron. In a few cases we observed several unknown lines. These are clearly lines from heavy impurities, possibly molybdenum. Some of these lines can be explained by the emission from Ti XIII
Temporary Bonding with Polydimethylglutarimide Based Lift Off Resist as a Layer Transfer Platform
Bonding of lift off resist (LOR) was performed to realize temporary wafer bonding without residue. Bonding process conditions such as spin speed, pre-bake temperature, and bonding temperature were optimized to obtain a large bonded area with high bond strength. Under optimized process conditions, a bonded area covering over 98% of the wafer surface, with a room temperature bond strength of nearly 5 J/m2 is achieved. During razor blade testing, fracture often occurs at the Si wafer. Moreover, debonding using an N-Methyl-2-pyrrolidone (NMP)-based solvent left the wafer surface extremely small amount of residue. Thus, the optimized bonding processed developed in this research is suitable for a clean temporary bonding process
- …