711 research outputs found
Evidence of late Quaternary environmental change in a continental east Antarctic lake from lacustrine sedimentary pigment distributions
A sediment core from Progress Lake, one of the oldest lacustrine sequences in East Antarctica, contains distinct zones dating from a previous interglacial (most likely Marine Isotope Stage 5e, c. 125-115 kyr BP) and the present interglacial (Marine Isotope Stage 1), separated by a transition zone representing when the lake became sub-glacial. Profiles of fossil pigments, determined using high performance liquid chromatography and liquid chromatography-tandem mass spectrometry, show distinct differences in the photoautotrophic community during these two interglacial periods. The first was dominated by algae and purple phototrophic bacteria, with periods of photic zone euxinia indicated by pigments from anoxygenic phototrophic bacteria. Specific chlorophyll a derivatives reveal periods when grazing pressure impacted significantly on the phytoplankton community. The virtual absence of pigments in the transition zone reflects severe restriction of photoautotrophic activity, consistent with the take having become sub-glacial. Retreat of snow and ice in the late Holocene (3345 C-14 yr Bp) allowed establishment of a less diverse primary producer community, restricted to algae and cyanobacteria. Grazers were severely restricted and oxidative transformation was more important than during the previous interglacial. The pigment data provide a unique and detailed insight in to the evolution of the lake ecology over an interglacial-glacial-interglacial transition and strong evidence that the Marine Isotope Stage 5e interglacial in this region of coastal East Antarctica was several degrees warmer than at present
Signal averaging x‐ray streak camera with picosecond jitter
We have developed an averaging picosecond x‐ray streak camera using a dc‐biased photoconductive switch as a generator of a high‐voltage ramp. The streak camera is operated at a sweep speed of up to 8 ps/mm, shot‐to‐shot jitter is less than ±1 ps. The streak camera has been used to measure the time history of broadband x‐ray emission from an ultrashort pulse laser‐produced plasma. Accumulation of the streaked x‐ray signals significantly improved the signal‐to‐noise ratio of the data obtained. © 1996 American Institute of Physics.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/69581/2/RSINAK-67-3-697-1.pd
Recommended from our members
Fringe-free, Background-free, Collinear Third Harmonic Generation FROG Measurements for Multiphoton Microscopy
Collinear pulse measurement tools useful at the full numerical aperture (NA) of multiphoton microscope objectives are a necessity for a quantitative characterization of the femtosecond pulses focused by these systems. In this letter, we demonstrate a simple new technique, for characterizing the pulse at the focus in a multiphoton microscope. This technique, a background-free, fringe-free, form of frequency-resolved optical gating, uses the third harmonic signal generated from a glass coverslip. Here it is used to characterize 100 fs pulses (typical values for a multiphoton microscope) at the focus of a 0.65 NA objective
ICON 2019: International Scientific Tendinopathy Symposium Consensus: Clinical Terminology
© Author(s) (or their employer(s)) 2019. No commercial re-use. See rights and permissions. Published by BMJ.Background Persistent tendon pain that impairs function has inconsistent medical terms that can influence choice of treatment.1 When a person is told they have tendinopathy by clinician A or tendinitis by clinician B, they might feel confused or be alarmed at receiving what they might perceive as two different diagnoses. This may lead to loss of confidence in their health professional and likely adds to uncertainty if they were to search for information about their condition. Clear and uniform terminology also assists inter-professional communication. Inconsistency in terminology for painful tendon disorders is a problem at numerous anatomical sites. Historically, the term ‘tendinitis’ was first used to describe tendon pain, thickening and impaired function (online supplementary figure S1). The term ‘tendinosis’ has also been used in a small number of publications, some of which were very influential.2 3 Subsequently, ‘tendinopathy’ emerged as the most common term for persistent tendon pain.4 5 To our knowledge, experts (clinicians and researchers) or patients have never engaged in a formal process to discuss the terminology we use. We believe that health professionals have not yet agreed on the appropriate terminology for painful tendon conditions.Peer reviewedFinal Accepted Versio
Baryon Stopping and Charged Particle Distributions in Central Pb+Pb Collisions at 158 GeV per Nucleon
Net proton and negative hadron spectra for central \PbPb collisions at 158
GeV per nucleon at the CERN SPS were measured and compared to spectra from
lighter systems. Net baryon distributions were derived from those of net
protons, utilizing model calculations of isospin contributions as well as data
and model calculations of strange baryon distributions. Stopping (rapidity
shift with respect to the beam) and mean transverse momentum \meanpt of net
baryons increase with system size. The rapidity density of negative hadrons
scales with the number of participant nucleons for nuclear collisions, whereas
their \meanpt is independent of system size. The \meanpt dependence upon
particle mass and system size is consistent with larger transverse flow
velocity at midrapidity for \PbPb compared to \SS central collisions.Comment: This version accepted for publication in PRL. 4 pages, 3 figures.
Typos corrected, some paragraphs expanded in response to referee comments, to
better explain details of analysi
A morphometric analysis of the infant calvarium and dura
Literature addressing the anatomic development of the dura and calvarium during childhood is limited. Nevertheless, histological features of a subdural neomembrane (NM), including its thickness and vascularity, developing in response to an acute subdural hematoma (SDH) have been compared to the dura of adults to estimate when an injury occurred. Therefore, we measured the morphometric growth of the calvarium and dura and the vascular density within the dura during infancy. The mean thicknesses of the calvarium and dura as a function of occipitofrontal circumference (OFC), as well as the mean number of vessels per 25× field, were determined from the right parasagittal midparietal bone lateral to the sagittal suture of 128 infants without a history of head trauma. Our results showed that as OFC increased, the mean thicknesses of the calvarium and dura increased while the vascular density within the dura decreased. Our morphometric data may assist in the interpretation of subdural NM occurring during infancy. We recommend future investigations to confirm and extend our present data, especially by evaluating cases during later infancy and beyond as well as by sampling other anatomic sites from the calvarium. We also recommend morphometric evaluation of subdural NM associated with SDH in infancy and childhood
Event-by-event fluctuations of the kaon to pion ratio in central Pb+Pb collisions at 158 GeV per Nucleon
We present the first measurement of fluctuations from event to event in the
production of strange particles in collisions of heavy nuclei. The ratio of
charged kaons to charged pions is determined for individual central Pb+Pb
collisions. After accounting for the fluctuations due to detector resolution
and finite number statistics we derive an upper limit on genuine
non-statistical fluctuations, perhaps related to a first or second order QCD
phase transition. Such fluctuations are shown to be very small.Comment: 4 pages, 2 figure
Lambda production in central Pb+Pb collisions at CERN-SPS energies
In this paper we present recent results from the NA49 experiment for
and hyperons produced in central Pb+Pb collisions at
40, 80 and 158 AGeV. Transverse mass spectra and rapidity distributions
for are shown for all three energies. The shape of the rapidity
distribution becomes flatter with increasing beam energy. The multiplicities at
mid-rapidity as well as the total yields are studied as a function of collision
energy including AGS measurements. The ratio at mid-rapidity and
in 4 has a maximum around 40 AGeV. In addition,
rapidity distributions have been measured at 40 and 80 AGeV, which
allows to study the / ratio.Comment: SQM proceedings. J. Phys. G: Nucl. Part. Phys.: submitte
- …