    Optimalization of the accuracy of indirect stroboscopic, high value rotary speed measurement

    No full text
    W artykule opisano pośrednią, optymalizowaną metodę pomiaru prędkości obrotowej za pomocą stroboskopu cyfrowego. Optymalizacja dotyczy poprawy dokładności wyznaczenia wartości estymaty prędkości obrotowej o dużej wartości (rzędu kilkudziesięciu tysięcy obrotów na minutę). Na podstawie przeprowadzonych pomiarów i obliczeń stwierdzono, iż opty-malizowana metoda pomiaru pozwala na kilkukrotne zmniejszenie warto-ści niepewności wyniku pomiaru w stosunku do metody konwencjonalnej.In the article, indirect optimalized method of rotary speed measurement by the use of digital stroboscope was described. Optimalization applies to the improvement of the accuracy of estimator of the rotary speed measurement calculation for high speeds values (at the order of ten thousands rotations per minute). On the base of calculations it was found, that it exists, for some optimal speed (Figure 1) at which estimator of the measurement uncertainty has a minimal value. On the base of measurements (Table 1) it was also computed, that the optimalization allows to minimize, several times, value of the relative measurement uncertainty (Table 2)

    Verification of the indication correctness of total harmonic distortion meters

    No full text
    W artykule opisano metodę sprawdzania dokładności wskazań mierników zawartości harmonicznych za pomocą sygnału napięciowego zawierającego wzorcową, ściśle określoną wartość współczynnika zawartości harmonicznych (THD). Wyznaczono zależność wartości THD oraz jego niepewności od kształtu trójkątnego sygnału napięciowego o zmiennej symetrii. Przedstawiono wyniki sprawdzenia właściwości metrologicznych miernika zniekształceń nieliniowych PMZ-8A na wybranym zakresie pomiarowym. Zweryfikowano dokładność zaproponowanej metody.In the article, method of total harmonic distortion meters accuracy verification, by the use of voltage signal with standard, exactly defined, value of total harmonic distortion (THD) factor was described. Dependence of THD factor value and its uncertainty as the relationship of triangle signal shape with changing symmetry was calculated. Results of metrological properties verification for PMZ-8A non-linear distortion meter on selected measuring range were shown. Accuracy of the proposed method was verified

    Accuracy analysis of capacity change calculation in two-parameter bridge by the use of Monte Carlo simulation

    No full text
    W artykule zamieszczono podstawowe informacje dotyczące niezrównoważonego mostka RC do jednoczesnego pomiaru zmiany wartości pojemności dwóch przetworników pojemnościowych. Przedstawiono założenia projektowe, niezbędne podczas analizy rzeczywistych warunków pracy mostka. Omówiono wyniki analizy dokładności wyznaczenia parametrów wyjściowych mostka metodą symulacji Monte Carlo. Przedstawiono kształty rozkładów zmian wartości pojemności czujników w zależności od wartości i znaku zmian pojemności obu czujników.In the paper the basic information concerning an unbalanced RC bridge for simultaneous measuring the capacity change of two capacitance sensors is presented. The bridge measurement circuit is shown in Fig. 1. The output voltage components are described by Eqs. (1), (2). In Section 2 there are given the simplifying assumptions (see Eq. (3)). The bridge output parameters are described by Eqs. (4), (5). During measurements, both output voltage components are calculated based on RMS voltage and phase angle measurements – Eqs. (6), (7). For determination of the output parameter accuracy the method of Monte Carlo simulation is proposed (Section 3). The view of the spreadsheet Excel application used for calculations is shown in Fig. 2. The modeled sensor capacitance changes are defined and the bridge output voltage parameters are calculated (Tab. 1). The shapes and parameters of the probability distributions of input variables are assumed (Tab. 2). Then the parameters of output variables are calculated – Eqs. (7), (8) and Tab. 3. In Tab. 4 the exemplary shapes of the probability distributions of capacity changes for both sensor are presented. In the summary (Section 4) the bridge output parameters and the probability distributions for all the analyzed cases are compared

    Diagnosis of the industrial resistance temperature detectors by means of internal forcing

    No full text
    W artykule przedstawiono podstawowe metody wyznaczania właściwości czujników temperatury za pomoca wymuszeń wewnętrznych. Omówiono główne właściwości rezystancyjnych czujników temperatury. Pokazano koncepcję diagnostyki statycznych właściwości przemysłowych platynowych czujników temperatury przy użyciu wewnętrznych wymuszeń prądowych. Przedstawiono budowę i zasadę działania ukłądu pomiarowego. Opisano kolejne etapy eksperymentu diagnostycznego. Omówiono wstępne wyniki testowania czujników temperatury za pomocą skokowego oraz impulsowego wymuszania prądowego.In this article, basic methods of the determination of temoerature sensors properties by the use of internal forcing are presented . Main information concerning Resistance temperature Detectors (RTD) is discussed. Conception of the diagnostics of static properties of Industrial Platinum Resistance Thermometers (IPRT) by the use of internal current forcing is presented. The structure and the manner of measurement system work are shown. The next steps of the diagnostic experiment were described. Preliminary results of temperature sensors testing by the use of Loop Current Step Response (LCSR-test) and Current Pulse Response (CPR-test) are presented

    Metrological properties of the set-up for comparison measurement of electromagnets

    No full text
    W artykule przedstawiono metodę pomiaru przenikalności magnetycznej zaworu elektromagnetycznego. Opisano metodę podstawienia, wykorzystywaną w pomiarach. Przeprowadzono analizę dokładności zaproponowanej metody oraz wskazano na główne źródła błędów, wpływających na niepewność wyznaczenia przenikalności magnetycznej rdzenia elektromagnesu.In this article a method for permeability measurement of electromagnetic valve was described. Two coefficients for investigation of magnetic path were proposed. A method of substitution used for calculation of these coefficient was described. Analysis of accuracy of proposed method was performed. It was also pointed, that the essential reason of errors is a change of magnetic loop dimensions. This change is a main source of total uncertainty of calculated permeability