158 research outputs found
PHIL photoinjector test line
LAL is now equiped with its own platform for photoinjectors tests and
Research and Developement, named PHIL (PHotoInjectors at LAL). This facility
has two main purposes: push the limits of the photoinjectors performances
working on both the design and the associated technology and provide a low
energy (MeV) short pulses (ps) electron beam for the interested users. Another
very important goal of this machine will be to provide an opportunity to form
accelerator physics students, working in a high technology environment. To
achieve this goal a test line was realised equipped with an RF source, magnets
and beam diagnostics. In this article we will desrcibe the PHIL beamline and
its characteristics together with the description of the first two
photoinjector realised in LAL and tested: the ALPHAX and the PHIN RF Guns
PHIL Accelerator at LAL - Diagnostic status
http://accelconf.web.cern.ch/AccelConf/BIW2010/papers/tupsm100.pdfInternational audienceThe "Photo-Injector at LAL" (PHIL : http://phil.lal.in2p3.fr/) is a new electron beam accelerator at LAL. This accelerator is dedicated to test and characterise electron photo-guns and high-frequency structures for future accelerator projects (like the next generation lepton colliders, CLIC, ILC). This machine has been designed to produce low energy (E<10 MeV), small emittance (epsilon < 10 pi.mm.mrad), high current (charge 2 nC/bunch) electrons bunch at low repetition frequency (frep<10Hz) [1]. The first beam has been obtained on the 4th of November 2009. This paper will describe the current status and the futures developments of the diagnostics devices on this machine
Low Energy Beam Measurements Using PHIL Accelerator at LAL, Comparison with PARMELA Simulations
http://accelconf.web.cern.ch/AccelConf/PAC2011/papers/wep210.pdfInternational audiencePHIL ("PHoto-Injector at LAL") is a new electron beam accelerator at LAL. This accelerator is dedicated to test and characterize electron RF-guns and to deliver electron beam to users. This machine has been designed to produce and characterise low energy (E<10 MeV), small emittance (e<10 p.mm.mrad), high brilliance electrons bunch at low repetition frequency (n<10Hz). The first beam has been obtained on the 4th of November 2009. The current RF-gun tested on PHIL is the AlphaX gun, a 2.5 cell S-band cavity designed by LAL for the plasma accelerator studies performed at the Strathclyde university. This paper will present the first AlphaX RF-gun characterizations performed at LAL on PHIL accelerator, and will show comparisons between measurements and PARMELA simulations
Baseline Design of the SuperB Factory Injection System
TUPPR088International audienceThe injection complex of the SuperB, B-factory project of INFN consists of a polarized electron gun, a positron production system, electron and positron linac sections, a positron damping ring and the transfer lines connecting these systems and the collider main rings. To keep the ultra high luminosity nearly constant, continuous injection of 4 GeV electrons and 7 GeV positrons in both Low Energy Ring (LER) and High Energy Ring (HER) is necessary. In this paper we describe the baseline design and the beam dynamics studies performed to evaluate the system performance
The CLIC positron source based on compton schemes
The CLIC polarized positron source is based on a positron production scheme in which polarized photons are produced by a Compton process. In one option, Compton backscattering takes place in a so-called “Compton ring”, where an electron beam of 1 GeV interacts with circularly-polarized photons in an optical resonator. The resulting circularly-polarized gamma photons are sent on to an amorphous target, producing pairs of longitudinally polarized electrons and positrons. The nominal CLIC bunch population is 4.2x109 particles per bunch at the exit of the Pre-Damping Ring (PDR). Since the photon flux coming out from a "Compton ring" is not sufficient to obtain the requested charge, a stacking process is required in the PDR. Another option is to use a Compton Energy Recovery Linac (ERL) where a quasicontinual stacking in the PDR could be achieved. A third option is to use a "Compton Linac" which would not require stacking. We describe the overall scheme as well as advantages and constraints of the three options
The CLIC Positron Sources Based on Compton Schemes
International audienceThe CLIC polarized positron source is based on a positron production scheme in which polarized photons are produced by Compton process. Compton backscattering happens in a so-called "Compton ring" where an electron beam of 1.06 GeV interacts with a powerful laser beam amplified in an optical resonator. The circularly-polarized gamma rays are sent on to a target, producing pairs of longitudinally polarized electrons and positrons. An Adiabatic Matching Device maximizes the capture of the positrons. A normal-conducting 2 GHz Linac accelerates the beam up to 2.424 GeV before injection into the Pre-Damping Ring (PDR). The nominal CLIC bunch population is 4.4x10**9 particles per bunch. Since the photon flux coming out from a "Compton ring" is not sufficient to obtain the requested charge, a stacking process is required in the PDR. Another option is to use a "Compton Energy Recovery Linac" where a quasi-continual stacking in the PDR could be achieved. A third option is to use a "Compton Linac" which would not require stacking. We describe the overall scheme as well as advantages and constraints of the three different options
- …