    PHIL photoinjector test line

    Full text link
    LAL is now equiped with its own platform for photoinjectors tests and Research and Developement, named PHIL (PHotoInjectors at LAL). This facility has two main purposes: push the limits of the photoinjectors performances working on both the design and the associated technology and provide a low energy (MeV) short pulses (ps) electron beam for the interested users. Another very important goal of this machine will be to provide an opportunity to form accelerator physics students, working in a high technology environment. To achieve this goal a test line was realised equipped with an RF source, magnets and beam diagnostics. In this article we will desrcibe the PHIL beamline and its characteristics together with the description of the first two photoinjector realised in LAL and tested: the ALPHAX and the PHIN RF Guns

    PHIL Accelerator at LAL - Diagnostic status

    No full text
    http://accelconf.web.cern.ch/AccelConf/BIW2010/papers/tupsm100.pdfInternational audienceThe "Photo-Injector at LAL" (PHIL : http://phil.lal.in2p3.fr/) is a new electron beam accelerator at LAL. This accelerator is dedicated to test and characterise electron photo-guns and high-frequency structures for future accelerator projects (like the next generation lepton colliders, CLIC, ILC). This machine has been designed to produce low energy (E<10 MeV), small emittance (epsilon < 10 pi.mm.mrad), high current (charge 2 nC/bunch) electrons bunch at low repetition frequency (frep<10Hz) [1]. The first beam has been obtained on the 4th of November 2009. This paper will describe the current status and the futures developments of the diagnostics devices on this machine

    Low Energy Beam Measurements Using PHIL Accelerator at LAL, Comparison with PARMELA Simulations

    No full text
    http://accelconf.web.cern.ch/AccelConf/PAC2011/papers/wep210.pdfInternational audiencePHIL ("PHo­to-In­jec­tor at LAL") is a new elec­tron beam ac­cel­er­a­tor at LAL. This ac­cel­er­a­tor is ded­i­cat­ed to test and char­ac­ter­ize elec­tron RF-guns and to de­liv­er elec­tron beam to users. This ma­chine has been de­signed to pro­duce and char­ac­terise low en­er­gy (E<10 MeV), small emit­tance (e<10 p.​mm.​mrad), high bril­liance elec­trons bunch at low rep­e­ti­tion fre­quen­cy (n<10Hz). The first beam has been ob­tained on the 4th of Novem­ber 2009. The cur­rent RF-gun test­ed on PHIL is the Al­phaX gun, a 2.5 cell S-band cav­i­ty de­signed by LAL for the plas­ma ac­cel­er­a­tor stud­ies per­formed at the Strath­clyde uni­ver­si­ty. This paper will pre­sent the first Al­phaX RF-gun char­ac­ter­i­za­tions per­formed at LAL on PHIL ac­cel­er­a­tor, and will show com­par­isons be­tween mea­sure­ments and PARMELA sim­u­la­tions

    Baseline Design of the SuperB Factory Injection System

    No full text
    TUPPR088International audienceThe injection complex of the SuperB, B-factory project of INFN consists of a polarized electron gun, a positron production system, electron and positron linac sections, a positron damping ring and the transfer lines connecting these systems and the collider main rings. To keep the ultra high luminosity nearly constant, continuous injection of 4 GeV electrons and 7 GeV positrons in both Low Energy Ring (LER) and High Energy Ring (HER) is necessary. In this paper we describe the baseline design and the beam dynamics studies performed to evaluate the system performance

    The CLIC positron source based on compton schemes

    Get PDF
    The CLIC polarized positron source is based on a positron production scheme in which polarized photons are produced by a Compton process. In one option, Compton backscattering takes place in a so-called “Compton ring”, where an electron beam of 1 GeV interacts with circularly-polarized photons in an optical resonator. The resulting circularly-polarized gamma photons are sent on to an amorphous target, producing pairs of longitudinally polarized electrons and positrons. The nominal CLIC bunch population is 4.2x109 particles per bunch at the exit of the Pre-Damping Ring (PDR). Since the photon flux coming out from a "Compton ring" is not sufficient to obtain the requested charge, a stacking process is required in the PDR. Another option is to use a Compton Energy Recovery Linac (ERL) where a quasicontinual stacking in the PDR could be achieved. A third option is to use a "Compton Linac" which would not require stacking. We describe the overall scheme as well as advantages and constraints of the three options

    The CLIC Positron Sources Based on Compton Schemes

    No full text
    International audienceThe CLIC polarized positron source is based on a positron production scheme in which polarized photons are produced by Compton process. Compton backscattering happens in a so-called "Compton ring" where an electron beam of 1.06 GeV interacts with a powerful laser beam amplified in an optical resonator. The circularly-polarized gamma rays are sent on to a target, producing pairs of longitudinally polarized electrons and positrons. An Adiabatic Matching Device maximizes the capture of the positrons. A normal-conducting 2 GHz Linac accelerates the beam up to 2.424 GeV before injection into the Pre-Damping Ring (PDR). The nominal CLIC bunch population is 4.4x10**9 particles per bunch. Since the photon flux coming out from a "Compton ring" is not sufficient to obtain the requested charge, a stacking process is required in the PDR. Another option is to use a "Compton Energy Recovery Linac" where a quasi-continual stacking in the PDR could be achieved. A third option is to use a "Compton Linac" which would not require stacking. We describe the overall scheme as well as advantages and constraints of the three different options