29 research outputs found

    Magnetic stimulation for non-homogeneous biological structures

    Get PDF
    BACKGROUND: Magnetic stimulation has gained relatively wide application in studying nervous system structures. This technology has the advantage of reduced excitation of sensory nerve endings, and hence results in quasi-painless action. It has become clinically accepted modality for brain stimulation. However, theoretical and practical solutions for assessment of induced current distribution need more detailed and accurate consideration. Some possible analyses are proposed for distribution of the current induced from excitation current contours of different shape and disposition. Relatively non-difficult solutions are shown, applicable for two- and three-dimensional analysis. METHODS: The boundary conditions for field analysis by the internal Dirichlet problem are introduced, based on the vector potential field excited by external current coils. The feedback from the induced eddy currents is neglected. Finite element modeling is applied for obtaining the electromagnetic fields distribution in a non-homogeneous domain. RESULTS: The distributions were obtained in a non-homogeneous structure comprised of homogeneous layers. A tendency was found of the induced currents to follow paths in lower resistivity layers, deviating from the expected theoretical course for a homogeneous domain. Current density concentrations occur at the boundary between layers, suggesting the possibility for focusing on, or predicting of, a zone of stimulation. CONCLUSION: The theoretical basis and simplified approach for generation of 3D FEM networks for magnetic stimulation analysis are presented, applicable in non-homogeneous and non-linear media. The inconveniences of introducing external excitation currents are avoided. Thus, the possibilities are improved for analysis of distributions induced by time-varying currents from contours of various geometry and position with respect to the medium

    Removal of power-line interference from the ECG: a review of the subtraction procedure

    Get PDF
    BACKGROUND: Modern biomedical amplifiers have a very high common mode rejection ratio. Nevertheless, recordings are often contaminated by residual power-line interference. Traditional analogue and digital filters are known to suppress ECG components near to the power-line frequency. Different types of digital notch filters are widely used despite their inherent contradiction: tolerable signal distortion needs a narrow frequency band, which leads to ineffective filtering in cases of larger frequency deviation of the interference. Adaptive filtering introduces unacceptable transient response time, especially after steep and large QRS complexes. Other available techniques such as Fourier transform do not work in real time. The subtraction procedure is found to cope better with this problem. METHOD: The subtraction procedure was developed some two decades ago, and almost totally eliminates power-line interference from the ECG signal. This procedure does not affect the signal frequency components around the interfering frequency. Digital filtering is applied on linear segments of the signal to remove the interference components. These interference components are stored and further subtracted from the signal wherever non-linear segments are encountered. RESULTS: Modifications of the subtraction procedure have been used in thousands of ECG instruments and computer-aided systems. Other work has extended this procedure to almost all possible cases of sampling rate and interference frequency variation. Improved structure of the on-line procedure has worked successfully regardless of the multiplicity between the sampling rate and the interference frequency. Such flexibility is due to the use of specific filter modules. CONCLUSION: The subtraction procedure has largely proved advantageous over other methods for power-line interference cancellation in ECG signals

    Effect of Contour Shape of Nervous System Electromagnetic Stimulation Coils on the Induced Electrical Field Distribution

    Get PDF
    BACKGROUND: Electromagnetic stimulation of the nervous system has the advantage of reduced discomfort in activating nerves. For brain structures stimulation, it has become a clinically accepted modality. Coil designs usually consider factors such as optimization of induced power, focussing, field shape etc. In this study we are attempting to find the effect of the coil contour shape on the electrical field distribution for magnetic stimulation. METHOD AND RESULTS: We use the maximum of the induced electric field stimulation in the region of interest as the optimization criterion. This choice required the application of the calculus of variation, with the contour perimeter taken as a pre-set condition. Four types of coils are studied and compared: circular, square, triangular and an 'optimally' shaped contour. The latter yields higher values of the induced electrical field in depths up to about 30 mm, but for depths around 100 mm, the circular shape has a slight advantage. The validity of the model results was checked by experimental measurements in a tank with saline solution, where differences of about 12% were found. In view the accuracy limitations of the computational and measurement methods used, such differences are considered acceptable. CONCLUSION: We applied an optimization approach, using the calculus of variation, which allows to obtain a coil contour shape corresponding to a selected criterion. In this case, the optimal contour showed higher intensities for a longer line along the depth-axis. The method allows modifying the induced field structure and focussing the field to a selected zone or line

    Dataset of manually measured QT intervals in the electrocardiogram

    Get PDF
    BACKGROUND: The QT interval and the QT dispersion are currently a subject of considerable interest. Cardiac repolarization delay is known to favor the development of arrhythmias. The QT dispersion, defined as the difference between the longest and the shortest QT intervals or as the standard deviation of the QT duration in the 12-lead ECG is assumed to be reliable predictor of cardiovascular mortality. The seventh annual PhysioNet/Computers in Cardiology Challenge, 2006 addresses a question of high clinical interest: Can the QT interval be measured by fully automated methods with accuracy acceptable for clinical evaluations? METHOD: The PTB Diagnostic ECG Database was given to 4 cardiologists and 1 biomedical engineer for manual marking of QRS onsets and T-wave ends in 458 recordings. Each recording consisted of one selected beat in lead II, chosen visually to have minimum baseline shift, noise, and artifact. In cases where no T wave could be observed or its amplitude was very small, the referees were instructed to mark a 'group-T-wave end' taking into consideration leads with better manifested T wave. A modified Delphi approach was used, which included up to three rounds of measurements to obtain results closer to the median. RESULTS: A total amount of 2*5*548 Q-onsets and T-wave ends were manually marked during round 1. To obtain closer to the median results, 8.58 % of Q-onsets and 3.21 % of the T-wave ends had to be reviewed during round 2, and 1.50 % Q-onsets and 1.17 % T-wave ends in round 3. The mean and standard deviation of the differences between the values of the referees and the median after round 3 were 2.43 ± 0.96 ms for the Q-onset, and 7.43 ± 3.44 ms for the T-wave end. CONCLUSION: A fully accessible, on the Internet, dataset of manually measured Q-onsets and T-wave ends was created and presented in additional file: 1 (Table 4) with this article. Thus, an available standard can be used for the development of automated methods for the detection of Q-onsets, T-wave ends and for QT interval measurements

    Ventricular beat detection in single channel electrocardiograms

    Get PDF
    BACKGROUND: Detection of QRS complexes and other types of ventricular beats is a basic component of ECG analysis. Many algorithms have been proposed and used because of the waves' shape diversity. Detection in a single channel ECG is important for several applications, such as in defibrillators and specialized monitors. METHODS: The developed heuristic algorithm for ventricular beat detection includes two main criteria. The first of them is based on steep edges and sharp peaks evaluation and classifies normal QRS complexes in real time. The second criterion identifies ectopic beats by occurrence of biphasic wave. It is modified to work with a delay of one RR interval in case of long RR intervals. Other algorithm branches classify already detected QRS complexes as ectopic beats if a set of wave parameters is encountered or the ratio of latest two RR intervals RR(i-1)/RR(i )is less than 1:2.5. RESULTS: The algorithm was tested with the AHA and MIT-BIH databases. A sensitivity of 99.04% and a specificity of 99.62% were obtained in detection of 542014 beats. CONCLUSION: The algorithm copes successfully with different complicated cases of single channel ventricular beat detection. It is aimed to simulate to some extent the experience of the cardiologist, rather than to rely on mathematical approaches adopted from the theory of signal analysis. The algorithm is open to improvement, especially in the part concerning the discrimination between normal QRS complexes and ectopic beats

    Biphasic pulses enhance bleomycin efficacy in a spontaneous canine genital tumor model of chemoresistance: Sticker sarcoma

    Get PDF
    Sticker's sarcoma (also known as transmissible venereal tumor) is a horizontally transmitted neoplasm of the dog, that is passed with coitus. It is a locally aggressive tumor with a low tendency to metastatic spread. The most common locations are the genitals, the nose, the perianal area. Standard treatment consists with chemotherapy with vincristine, however other therapies such as, cryotherapy, immunotherapy or, in selected cases, radiation therapy, have been reported. In this article we describe the outcome of a small cohort of canine patients, with chemotherapy resistant transmissible venereal tumor (TVT), treated with bleomycin selectively driven by trains of biphasic pulses (electrochemotherapy). Three canine patients, with refractory TVT, entered the study and received two sessions of ECT under sedation. The pets had local injection of bleomycin at the concentration of 1.5 mg/ml and five minutes after the chemotherapy, trains of 8 biphasic electric pulses lasting 50 + 50 μs each, with 1 ms interpulse intervals, were delivered by means of modified caliper or, for difficult districts, through paired needle electrode. All the patients responded to the treatment and are still in remission at different times. Electrochemotherapy appears as a safe and efficacious modality for the treatment of TVT and warrants further investigations

    Atmosféra hraného filmu

    No full text

    Systolic Architecture for Adaptive Censoring CFAR PI Detector

    No full text
    A new parallel algorithm for signal processing and a parallel systolic architecture of a robust constant false alarm rate (CFAR) processor with post-detection integration and adaptive censoring (RACPI) is presented in the paper. This detector is effective in conditions of flow from strong impulse interference. The ACPI CFAR processor uses sorting and censoring algorithms. We offer the sorting algorithm to be realized on the basis of the odd-even transposition sort method. We propose the censoring algorithm to be used for obtaining of the noise level estimation and for estimation of the impulse interference parameters. These parameters are needed for automatically choosing the scale factor, which keeps the false alarm rate constant. The real-time implementation of this detection algorithm requires large computational resources because of the great volume and high speed of the incoming data. The time consumption of the sorting and censoring procedures is also very high and therefore the practical realization is difficult. For all these reasons, we choose systolic architectures in the considered case for being more effective than conventional multiprocessor architectures. The computational losses of the systolic architecture are estimated in terms of the number of the processor elements, the computational time and the speed-up needed for realtime implementation. 1

    Minimally invasive extractions with physics forceps – clinical evaluation and comparison

    No full text
    Introduction: Tooth extraction is still one of the most common dental procedures, routinely performed for a variety of reasons. Tooth extraction forceps and elevators are well-known extraction instruments which have been the standard in tooth extraction procedures for well over a hundred years. Physics forceps are one possible alternative, aiming to perform less traumatic and more predictable extractions. Aim: The aim of study was to compare the effectiveness of physics forceps as an alternative, less traumatic, tool to the conventional extraction forceps. Materials and methods: All patients in the study were split into two groups: 26 patients in whom conventional extraction forceps were used (a control group) and 28 patients in whom we used physics forceps (a study group). For each group, we assessed the success of the extraction, the buccal cortical plate preservation, pain experience, and early wound healing. Results: There was no statistically significant difference in extraction success scores between the two groups. Physics forceps extractions preserved the buccal cortical plate in 81.1% of instances, while traditional forceps extractions did so in 71.8%. The patients in the study group reported less pain on the seventh day. At 10 days, the study group had a marginally higher proportion of completely healed extraction wounds. Conclusions: Atraumatic extractions preserve more hard and soft tissues at the extraction site. Physics forceps are a tool similar to the well-known conventional extraction forceps. They provide for somewhat better results in most extractions