6 research outputs found

    Determination of the isoelectric point value of 3-mercaptopyruvate sulfurtransferase and its shift by treatment with oxidized glutathione.

    Get PDF
    The isoelectric point (pI) value of 3-mercaptopyruvate sulfurtransferase (MST) from human erythrocytes was determined to be 6.3 at 10 degrees C by isoelectric focusing in horizontal slab polyacrylamide gel containing 2% carrier ampholyte (pH 3-10). The value was determined by comparison with the electrofocused bands of bovine pancreatic ribonuclease A-glutathione mixed disulfides (RNase-SG), which were composed of 8 species containing 1 (RNase-SG1) through 8 (RNase-SG8) moles of glutathione per mole of ribonuclease A with different pI values ranging from 5.3 (RNase-SG8) to 8.8 (RNase-SG1). The pI value of the same enzyme in a 110,000 X g supernatant of rat liver was 5.9, which was the same as that of rat erythrocyte enzyme. Treatments of rat hemolysate with oxidized glutathione or diamide resulted in a shift of the pI of MST to a lower value, 5.7-5.5. This shift was inhibited when these treatments were performed in the presence of dithiothreitol. These results indicate that the treatment of the enzyme with oxidized glutathione results in the formation of enzyme-glutathione mixed disulfide.</p

    Preparation of a volatile derivative of taurine and application to gas chromatographic determination of urinary taurine.

    Get PDF
    A new volatile derivative of taurine, N-isobutoxycarbonyltaurine methyl ester (methyl 2-(N-isobutoxycarbonylamino)ethanesulfonate), was prepared by a three-step procedure for the gas chromatographic determination of taurine in urine. First, taurine was converted to its silver salt by reaction with silver oxide; next the silver salt was reacted with isobutyl chloroformate to form the N-isobutoxycarbonyl derivative, and finally the derivative was reacted with methyl iodide to form N-isobutoxycarbonyltaurine methyl ester. The volatile derivative was analyzed by gas chromatography using a column of 3% OV-101 on Chromosorb W. When methyl 3-(N-isobutoxycarbonylamino) propanesulfonate was used as an internal standard, the calibration curve was linear between 0.5 and 5.0 mumol of taurine/ml and showed a good reproducibility. This method was applied to the determination of taurine in human urine. Recovery was 98.6 +/- 5.2%, when 1.25 to 5.0 mumol/ml of taurine was added to human urine.</p

    Visualization of sialoglycoproteins in polyacrylamide gels by acidic ninhydrin reaction.

    Get PDF
    A new method for staining sialoglycoproteins in polyacrylamide gel after disc electrophoresis is described. The method utilizes the reaction of sialic acids with an acidic ninhydrin reagent which yields a stable color with an absorption maximum at 470 nm. After electrophoresis, the polyacrylamide gel is placed in a test tube and heated with 5 ml of the acidic ninhydrin reagent for 10 min in a boiling water bath. Sialoglycoproteins are detected as brown bands. No additional procedure such as destaining is necessary. When 20 micrograms fetuin, a sialoglycoprotein, per gel is applied, the band remains visible for at least 2 h. Stained gel can be scanned with a gel scanner at 470 nm. When the stained gel was dried on a sheet of polypropylene filter, the color was stable for at least one month. The present method is superior to the method using Stains-all (3,3'-diethyl-9-methyl-4,5,4',5'-dibenzothiacarbocyanine) in specificity and simplicity for the detection of sialoglycoproteins.</p
    corecore