11 research outputs found

    Multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) in the evaluation of the mandibular invasion by squamous cell carcinomas (SCC) of the oral cavity. Correlation with pathological data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To retrospectively compare the diagnostic accuracy of magnetic resonance imaging (MRI) and multidetector-row computed tomography (MDCT) in the assessment of the mandibular invasion by squamous cell carcinoma (SCC) having histopathological exams as standard of reference.</p> <p>Materials and methods</p> <p>Institutional review board approval with a waiver of informed patient consent was obtained. Of the 147 patients selected from our database who underwent surgical excision of a tumour arising into the oral cavity, thirty-six patients (26 men, 10 women; mean age, 56 years; range, 30-75 years) with hystologically proven SCC who performed both a preoperative MRI and MDCT, composed our final study population.</p> <p>Images were qualitatively analyzed in consensus by two expert radiologist in head and neck imaging. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were assessed for both MRI and MDCT.</p> <p>Differences in sensitivity, specificity, positive and negative predictive values were calculated at a statistical significance of p < .05.</p> <p>Results</p> <p>The sensitivity, the specificity and the accuracy of MRI and MDCT in the detection of the mandibular involvement were respectively 93%, 82%, 86% and 79%, 82%, 81%, while the positive predictive value (PPV) and negative predictive value (NPV) were respectively 76%, 95% and 73%, 86%. There wasn't any statistically significant difference in overall diagnostic accuracy between MRI and MDCT in the evaluation of mandibular tumour invasion (p > .05).</p> <p>Conclusion</p> <p>MRI showed to have a higher sensitivity compare to MDCT in the assessment of mandibular involvement from SCC arising in the oral cavity although none statistically significant differences were noted.</p

    Congenital asymptomatic diaphragmatic hernias in adults: a case series.

    Get PDF
    Introduction. Congenital diaphragmatic hernia is a major malformation occasionally found in newborns and babies. Congenital diaphragmatic hernia is defined by the presence of an orifice in the diaphragm, more often to the left and posterolateral, that permits the herniation of abdominal contents into the thorax. The aim of this case series is to provide information on the presentation, diagnosis and outcome of three patients with late-presenting congenital diaphragmatic hernias. The diagnosis of congenital diaphragmatic hernia is based on clinical investigation and is confirmed by plain X-ray films and computed tomography scans. Case presentations. In the present report three cases of asymptomatic abdominal viscera herniation within the thorax are described. The first case concerns herniation of some loops of the large intestine into the left hemi-thorax in a 75-year-old Caucasian Italian woman. The second case concerns a rare type of herniation in the right side of the thorax of the right kidney with a part of the liver parenchyma in a 57-year-old Caucasian Italian woman. The third case concerns herniation of the stomach and bowel into the left side of the chest with compression of the left lung in a 32-year-old Caucasian Italian man. This type of hernia may appear later in life, because of concomitant respiratory or gastrointestinal disease, or it may be an incidental finding in asymptomatic adults, such as in the three cases featured here. Conclusions: Patients who present with late diaphragmatic hernias complain of a wide variety of symptoms, and diagnosis may be difficult. Additional investigation and research appear necessary to better explain the development and progression of this type of disease. © 2013 Bianchi et al.; licensee BioMed Central Ltd

    Effect of varying contrast material iodine concentration and injection technique on the conspicuity of hepatocellular carcinoma during 64-section MDCT of patients with cirrhosis

    No full text
    Objectives: The aim of this study was to compare the intraindividual effects of contrast material with two different iodine concentrations on the conspicuity of hepatocellular carcinoma (HCC) and vascular and hepatic contrast enhancement during multiphasic, 64-section multidetector row CT (MDCT) in patients with cirrhosis using two contrast medium injection techniques. Methods: Patients were randomly assigned to one of two groups with an equal iodine dose but different contrast material injection techniques: scheme A, fixed injection duration (25 s), and scheme B, fixed injection flow rate (4 ml s(-1)). For each group, patients were randomised to receive both moderate-concentration contrast medium (MCCM) and high-concentration contrast medium (HCCM) during two CT examinations within 3 months. Enhancement of the aorta, liver and portal vein and the tumour-to-liver contrast-to-noise ratio (CNR) were compared between MCCM and HCCM. Results: 30 patients (mean age 59 years; range 45-80 years; 16 patients in scheme A and 14 in scheme B) with a total of 31 confirmed HCC nodules were prospectively enrolled. For scheme B, the mean contrast enhancement of the aorta and tumour-to-liver CNR were significantly higher with HCCM than with MCCM during the hepatic arterial phase (+350.5 HU vs +301.1 HU, p=0.001, and +7.5 HU vs + 5.5 HU, p=0.004). For both groups, there was no significant difference between MCCM and HCCM for all other comparisons. Conclusion: For a constant injection flow rate, HCCM significantly improves the conspicuity of HCC lesions and aortic enhancement during the hepatic arterial phase on 64-section MDCT in patients with cirrhosis

    Prospective comparative evaluation of quantitative-elastosonography (Q-elastography) and contrast-enhanced ultrasound for the evaluation of thyroid nodules: Preliminary experience

    No full text
    Purpose: To assess the effectiveness of semiquantitative elastosonography (Q-elastography) compared with contrast-enhanced ultrasound (CEUS) in differentiating the nature of thyroid nodules. Methods and materials: Forty-eight consecutive patients (35 males, 13 females, range: 34-69 years, mean: 49.4 years), candidate to surgery, previously detected at color-Doppler ultrasound (CDUS), were prospectively examined with elastosonography with dedicated semiquantitative software (Q-Elastography, Toshiba XG) and CEUS (Technos Mylab 70 Gold X, and Toshiba XG) before surgery. CEUS and elastosonography were evaluated by two investigators in consensus. Comparison between the CEUS pattern and elastonographic strain ratio observed and expected frequencies for the diagnoses was evaluated with chi(2) test or with Fisher exact test. Results: Fifty-three nodules (19 papillary carcinoma, 32 hyperplasia, and 2 follicular adenoma) in 48 patients were available for analysis. Regarding echogenicity score, sensitivity, specificity, PPV and NPV of conventional US were 81%, 50%, 56%, 77%; according to Q-elastography, sensitivity, specificity, PPV and NPV were 95%, 88%, 97% and 91% respectively; whereas concerning CEUS, sensitivity specificity PPV and NPV were 79%, 91%, 83% and 89% respectively. Both CEUS and Q-elastography were more specific than US (p < 0.01), with not statistical significant difference with regard to sensitivity. Conclusions: The results of the present study suggest that Q-elastography is a valuable tool in the characterization of thyroid nodules and it seems to be more sensitive than CEUS. (C) 2013 Elsevier Ireland Ltd. All rights reserved

    Cutaneous melanoma follow-up: Appropriateness of requests for ultrasound tests - The S.Gallicano national referral centre experience

    Get PDF
    BACKGROUND: Cutaneous melanoma is a malignant neoplasm with a constantly increasing incidence, the prognosis of which is largely dependent on early diagnosis. The appropriateness of requests for ultrasound (US) tests during melanoma follow-up of patients referred to our institute was evaluated. PATIENTS AND METHODS: The requests for US tests of all patients referred to our institute over a four-month period were assessed. In order to correctly evaluate the appropriateness of requests, patients were split into two groups on the basis of melanoma thickness: > 1 mm (Group A) and < 1 mm (Group B). RESULTS: 546 patients were enrolled in our study out of a total of 1240 US tests performed. Out of 290 Group A patients, 104 patients (35%) did not meet the established congruity criteria. Group B was composed of 256 individuals, 92 patients (35.9%) of which were found to have at least one inappropriate request. CONCLUSION: In our study, more than 30% of the requests for US tests were found to be inappropriate, to the detriment of those with a real need for diagnostic testing. This lengthens waiting lists and it may also increase public healthcare costs. Therefore, it is mandatory to adopt new, widely accepted and easily applicable guidelines

    New-Generation ASiR-V for Dose Reduction While Maintaining Image Quality in CT: A Phantom Study

    No full text
    Over the last few decades, the need to reduce and optimize patient medical radiation exposure has prompted the introduction of novel reconstruction algorithms in computed tomography (CT). Against this backdrop, the present study aimed to assess whether reduced radiation dose CT images reconstructed with the new-generation adaptive statistical iterative reconstruction (ASiR-V) maintain the same image quality as that of routine image reconstruction. In addition, the optimization of image quality parameters for the ASiR-V algorithm (e.g., an optimal combination of blending percentage and noise index (NI)) was investigated. An abdominal reference phantom was imaged using the routine clinical protocol (fixed noise index of 18 and 40% ASiR reconstruction). Reduced radiation dose CT scans were performed with varying NI (22, 24, and 30) and using the ASiR-V reconstruction algorithm. Quantitative and qualitative analyses of image noise, contrast, and resolution were performed against NI and reconstruction blending percentages. Our results confirm the ability of the ASiR-V algorithm to provide images of high diagnostic quality while reducing the patient dose. All the parameters were improved in ASiR-V images as compared to ASiR. Both quantitative and qualitative analyses showed that the best agreement was obtained for the images reconstructed using ASiR-V with NI24 and a high percentage of blending (70–100%). This preliminary study results show that ASiR-V allows for a significant reduction in patient dose (about 40%) while maintaining a good overall image quality when appropriate NI (i.e., 24) is used