4 research outputs found
Potential for wind energy generation in Piracicaba, SP, Brazil
Wind power has gained space in Brazil's energy matrix, being a clean source and inexhaustible. Therefore, it becomes important to characterize the wind potential of a given location, for future applications. The main objective of the present study was to estimate the wind energy potential in Piracicaba, SP, Brazil. The wind speed data were collected by an anemometer installed at the Meteorological Station Luiz de Queiroz College of Agriculture, Piracicaba-SP. The wind speed variability was represented by the Weibull frequency distribution, a probability density function of two parameters (k and c). The parameters k and c were used to correlate the Gamma function with the annual average wind speed, the variance and power mean density. A wind profile was made to evaluate the behavior of historical average speeds at higher altitudes measured by anemometer, to estimate the gain in power density. The values of k for all heights were close to 1 which corresponds to a wind regime highly variable, and c values were also low representing a low average speed of the location. The location was characterized as being unfavorable for the application of wind turbines for power generation
Metrological assessment of TDR performance for measurement of potassium concentration in soil solution
ABSTRACT Despite the growing use of the time domain reflectometry (TDR) technique to monitoring ions in the soil solution, there are few studies that provide insight into measurement error. To overcome this lack of information, a methodology, based on the central limit theorem error, was used to quantify the uncertainty associated with using the technique to estimate potassium ion concentration in two soil types. Mathematical models based on electrical conductivity and soil moisture derived from TDR readings were used to estimate potassium concentration, and the results were compared to potassium concentration determined by flame spectrophotometry. It was possible to correct for random and systematic errors associated with TDR readings, significantly increasing the accuracy of the potassium estimation methodology. However, a single TDR reading can lead to an error of up to ± 18.84 mg L-1 K+ in soil solution (0 to 3 dS m-1), with a 95.42% degree of confidence, for a loamy sand soil; and an error of up to ± 12.50 mg L-1 of K+ (0 to 2.5 dS m-1) in soil solution, with a 95.06% degree of confidence, for a sandy clay soil