8 research outputs found
Combined recurrent laryngeal nerve monitoring and one-lung ventilation using the EZ-Blocker and an electromyographic endotracheal tube
Background
Intraoperative neuromuscular monitoring (IONM) is a widespread procedure to identify and protect the recurrent laryngeal nerve (RLN) during thyroid surgery. However, for left thoracic surgery with high risk of RLN injury, both reliable recurrent laryngeal nerve monitoring and one-lung ventilation could interfere.
Methods
In this prospective study, a new method for IONM during one-lung ventilation combining RLN monitoring with an electromyographic (EMG) endotracheal tube (ETT) and lung separation using the EZ-Blocker (EZB) is described and its clinical feasibility and effectiveness were assessed.
Results
A total of 14 patients undergoing left upper lobe surgery and left upper mediastinal lymph node dissection were enrolled. The EZB was introduced and positioned without any problems and sufficient lung collapse was achieved in all patients. No tracheobronchial injuries or immediate complications occurred. A stable EMG signal was present in all patients and no RLN palsy and no negative side effects of the NIM EMG ETT or the EZB were observed postoperatively.
Conclusions
The described method is technically feasible, easy to apply and save. It provides both reliable IONM and independent lung separation for optimal surgical exposure. The combined use of the EZB and the NIM EMG ETT might reduce the risk for RLN palsy and impaired lung separation during left thoracic surgery with high risk for RLN injury
Comparison of GlidescopeÂŽ Goâ˘, King Visionâ˘, Dahlhausen VL, IâView⢠and Macintosh laryngoscope use during difficult airway management simulation by experienced and inexperienced emergency medical staff: A randomized crossover manikin study
Background
In pre-hospital emergency care, video laryngoscopes (VLs) with disposable blades are preferably used due to hygienic reasons. However, there is limited existing data on the use of VLs with disposable blades by emergency medical staff. Therefore, the aim of this study was to compare the efficacy of four different VLs with disposable blades and the conventional standard Macintosh laryngoscope, when used by anesthetists with extensive previous experience and paramedics with little previous experience in endotracheal intubation (ETI) in a simulated difficult airway.
Methods
Fifty-eight anesthetists and fifty-four paramedics participated in our randomized crossover manikin trial. Each performed ETI with the new GlidescopeÂŽ Goâ˘, the Dahlhausen VL, the King Visionâ˘, the I-View⢠and the Macintosh laryngoscope. âTime to intubateâ was the primary endpoint. Secondary endpoints were âtime to vocal cordsâ, âtime to ventilateâ, overall success rate, number of intubation attempts and optimization maneuvers, Cormack-Lehane score, severity of dental compression and subjective impressions.
Results
The GlidescopeÂŽ Goâ˘, the Dahlhausen VL and the King Vision⢠provided superior intubation conditions in both groups without affecting the number of intubation attempts or the time required for successful intubation. When used by anesthetists with extensive experience in ETI, the use of VLs did not affect the overall success rate. In the hands of paramedics with little previous experience in ETI, the failure rate with the Macintosh laryngoscope (14.8%) decreased to 3.7% using the GlidescopeÂŽ Go⢠and the Dahlhausen VL. Despite the advantages of hyperangulated video laryngoscopes, the I-View⢠performed worst.
Conclusions
VLs with hyperangulated blades facilitated ETI in both groups and decreased the failure rate by an absolute 11.1% when used by paramedics with little previous experience in ETI. Our results therefore suggest that hyperangulated VLs could be beneficial and might be the method of choice in comparable settings, especially for emergency medical staff with less experience in ETI
The EZ-blocker for one-lung ventilation in patients undergoing thoracic surgery: clinical applications and experience in 100 cases in a routine clinical setting
Abstract Background In certain clinical situations the insertion of a double-lumen tube (DLT) for one-lung ventilation (OLV) is not feasible or unfavorable. In these cases, the EZ-Blocker (EZB) may serve as an alternative. The aim of our analysis was to report on the clinical applications and our experience with the EZB for one-lung ventilation in 100 patients undergoing thoracic surgery. Methods All anesthetic records from patients older than 18Â years of age undergoing general anesthesia in the department of thoracic surgery with intraoperative use of an EZB for OLV at the University Hospital of Erlangen in four consecutive years were analyzed retrospectively. Results Most frequently, EZB was used in difficult airway (27%) and for surgical procedures with high risk for left recurrent laryngeal nerve injury (21%), followed by application in intubated (12%) or tracheostomized (11%) patients. 11% of the patients had an increased risk of gastric regurgitation. Almost all EZBs were placed free of complications (99%). Clinically sufficient lung collapse was achieved in all patients. No serious airway injuries or immediate complications were documented. Conclusions The EZB is an efficient, easy-to-use and safe airway device and enables OLV in several clinical situations, when conventional DLTs are not feasible or less favorable. Three major applications were depicted from the data: expected difficult airway, surgical procedures with necessity of intraoperative recurrent laryngeal nerve monitoring and already intubated or tracheostomized patients
Airway management in a twoâyearâold child with a tongue tumor using video laryngoscopeâassisted flexible bronchoscopic nasotracheal intubation (hybrid technique)
Key Clinical Message Airway management in children can be challenging. A hybrid technique using a video laryngoscopeâassisted flexible bronchoscopic nasotracheal intubation allowed a successful airway management in a twoâyearâold child with a large tongue tumor