27 research outputs found
Evaluation of Surface Residual Stresses in Friction Stir Welds Due to Laser and Shot Peening
The effects of laser, and shot peening on the residual stresses in Friction Stir Welds (FSW) has been investigated. The surface residual stresses were measured at five different locations across the weld in order to produce an adequate residual stress profile. The residual stresses before and after sectioning the coupon from the welded plate were also measured, and the effect of coupon size on the residual stress relaxation was determined and characterized. Measurements indicate that residual stresses were not uniform along the welded plate, and large variation in stress magnitude could be exhibited at various locations along the FSW plate. Sectioning resulted in significant residual stress relaxation in the longitudinal direction attributed to the large change in dimensions in this direction. Overall, Laser and shot peening resulted in a significant reduction in tensile residual stresses at the surface of the specimens
Use of Flexible Sensor to Characterize Biomechanics of Canine Skin
Background Suture materials and techniques are frequently evaluated in ex vivo studies by comparing tensile strengths. However, the direct measurement techniques to obtain the tensile forces in canine skin are not available, and, therefore, the conditions suture lines undergo is unknown. A soft elastomeric capacitor is used to monitor deformation in the skin over time by sensing strain. This sensor was applied to a sample of canine skin to evaluate its capacity to sense strain in the sample while loaded in a dynamic material testing machine. The measured strain of the sensor was compared with the strain measured by the dynamic testing machine. The sample of skin was evaluated with and without the sensor adhered.
Results In this study, the soft elastomeric capacitor was able to measure strain and a correlation was made to stress using a modified Kelvin-Voigt model for the canine skin sample. The sensor significantly increases the stiffness of canine skin when applied which required the derivation of mechanical models for interpretation of the results.
Conclusions Flexible sensors can be applied to canine skin to investigate the inherent biomechanical properties. These sensors need to be lightweight and highly elastic to avoid interference with the stress across a suture line. The sensor studied here serves as a prototype for future sensor development and has demonstrated that a lightweight highly elastic sensor is needed to decrease the effect on the sensor/skin construct. Further studies are required for biomechanical characterization of canine skin
Cryomilled Zinc Sulfide: A prophylactic for Staphylococcus aureus infected wounds
Bacterial pathogens that colonize wounds form biofilms, which protect the bacteria from the effect of host immune response and antibiotics. This study examined the effectiveness of newly synthesized zinc sulfide in inhibiting biofilm development by Staphylococcus aureus (S. aureus) strains. Zinc sulfide (ZnS) was anaerobically biosynthesized to produce CompA, which was further processed by cryomilling to maximize the antibacterial properties to produce CompB. The effect of the two compounds on the S. aureus strain AH133 was compared using zone of inhibition assay. The compounds were formulated in a polyethylene glycol cream. We compared the effect of the two compounds on biofilm development by AH133 and two methicillin-resistant S. aureus clinical isolates using the in vitro model of wound infection. Zone of inhibition assay revealed that CompB is more effective than CompA. At 15 mg/application, the formulated cream of either compound inhibited biofilm development by AH133, which was confirmed using confocal laser scanning microscopy. At 20 mg/application, CompB inhibited biofilm development by the two methicillin-resistant S. aureus clinical isolates. To further validate the effectiveness of CompB, mice were treated using the murine model of wound infection. Colony forming cell assay and in vivo live imaging results strongly suggested the inhibition of S. aureus growth
Three dimensional printed biofilms: Fabrication, design and future biomedical and environmental applications
Abstract Three dimensional printing has emerged as a widely acceptable strategy for the fabrication of mammalian cell laden constructs with complex microenvironments for tissue engineering and regenerative medicine. More recently 3D printed living materials containing microorganisms have been developed and matured into living biofilms. The potential for engineered 3D biofilms as in vitro models for biomedical applications, such as antimicrobial susceptibility testing, and environmental applications, such as bioleaching, bioremediation, and wastewater purification, is extensive but the need for an in‐depth understanding of the structure–function relationship between the complex construct and the microorganism response still exists. This review discusses 3D printing fabrication methods for engineered biofilms with specific structural features. Next, it highlights the importance of bioink compositions and 3D bioarchitecture design. Finally, a brief overview of current and potential applications of 3D printed biofilms in environmental and biomedical fields is discussed
Effect of pseudomonas lipase enzyme on the degradation of polycaprolactone/polycaprolactone-polyglycolide fiber blended nanocomposites
This study describes the interaction resulting from adding pseudomonas lipase (PS) enzyme to polycaprolactone-based composites designed for orthopedic applications. The biopolymer composite evaluated in this study consists of electrospun polycaprolactone (PCL)/polyglycolide (PGA) blended fibers impregnated with double stranded deoxyribonucleic acid wrapped single-walled carbon nanotubes encapsulated by a PCL matrix. PS enzyme was used to catalyze the degradation of PCL-based biocomposites. PCL present in the biocomposites showed considerable degradation in 4 weeks in the presence of the enzyme, exhibiting a contrast to hydrolytic degradation which lasts several years. PGA-consisting fibers degraded completely within one week of exposure to the enzyme
Sulfated Hydrogels in Intervertebral Disc and Cartilage Research
Hydrogels are commonly used for the 3D culture of musculoskeletal cells. Sulfated hydrogels, which have seen a growing interest over the past years, provide a microenvironment that help maintain the phenotype of chondrocytes and chondrocyte-like cells and can be used for sustained delivery of growth factors and other drugs. Sulfated hydrogels are hence valuable tools to improve cartilage and intervertebral disc tissue engineering. To further advance the utilization of these hydrogels, we identify and summarize the current knowledge about different sulfated hydrogels, highlight their beneficial effects in cartilage and disc research, and review the biofabrication processes most suitable to secure best quality assurance through deposition fidelity, repeatability, and attainment of biocompatible morphologies
Use of flexible sensor to characterize biomechanics of canine skin
Abstract Background Suture materials and techniques are frequently evaluated in ex vivo studies by comparing tensile strengths. However, the direct measurement techniques to obtain the tensile forces in canine skin are not available, and, therefore, the conditions suture lines undergo is unknown. A soft elastomeric capacitor is used to monitor deformation in the skin over time by sensing strain. This sensor was applied to a sample of canine skin to evaluate its capacity to sense strain in the sample while loaded in a dynamic material testing machine. The measured strain of the sensor was compared with the strain measured by the dynamic testing machine. The sample of skin was evaluated with and without the sensor adhered. Results In this study, the soft elastomeric capacitor was able to measure strain and a correlation was made to stress using a modified Kelvin-Voigt model for the canine skin sample. The sensor significantly increases the stiffness of canine skin when applied which required the derivation of mechanical models for interpretation of the results. Conclusions Flexible sensors can be applied to canine skin to investigate the inherent biomechanical properties. These sensors need to be lightweight and highly elastic to avoid interference with the stress across a suture line. The sensor studied here serves as a prototype for future sensor development and has demonstrated that a lightweight highly elastic sensor is needed to decrease the effect on the sensor/skin construct. Further studies are required for biomechanical characterization of canine skin
Numerical Investigation of Auxetic Textured Soft Strain Gauge for Monitoring Animal Skin
Recent advances in hyperelastic materials and self-sensing sensor designs have enabled the creation of dense compliant sensor networks for the cost-effective monitoring of structures. The authors have proposed a sensing skin based on soft polymer composites by developing soft elastomeric capacitor (SEC) technology that transduces geometric variations into a measurable change in capacitance. A limitation of the technology is in its low gauge factor and lack of sensing directionality. In this paper, we propose a corrugated SEC through surface texture, which provides improvements in its performance by significantly decreasing its transverse Poisson’s ratio, and thus improving its sensing directionality and gauge factor. We investigate patterns inspired by auxetic structures for enhanced unidirectional strain monitoring. Numerical models are constructed and validated to evaluate the performance of textured SECs, and to study their performance at monitoring strain on animal skin. Results show that the auxetic patterns can yield a significant increase in the overall gauge factor and decrease the stress experienced by the animal skin, with the re-entrant hexagonal honeycomb pattern outperforming all of the other patterns.This article is published as Liu, Han, Matthias Kollosche, Jin Yan, Eric M. Zellner, Sarah A. Bentil, Iris V. Rivero, Colin Wiersema, and Simon Laflamme. "Numerical investigation of auxetic textured soft strain gauge for monitoring animal skin." Sensors 20, no. 15 (2020): 4185.
DOI: 10.3390/s20154185.
Copyright 2020 by the authors.
Attribution 4.0 International (CC BY 4.0).
Posted with permission