3,950 research outputs found

    Comparative evaluation of a novel, moderately hypofractionated radiation protocol in 56 dogs with symptomatic intracranial neoplasia

    Get PDF
    BACKGROUND: Use of strongly hypofractionated radiation treatments in dogs with intracranial neoplasia did not improve outcomes and yielded increased rates of toxicosis. OBJECTIVES: To evaluate safety and efficacy of a new, moderately hypofractionated radiation protocol of 10 × 4 Gy compared to a standard protocol. ANIMALS: Convenience sample of 56 client-owned dogs with primary symptomatic brain tumors. METHODS: Retrospective observational study. Twenty-six dogs were assigned to the control standard protocol of 20 × 2.5 Gy (group A) and 30 dogs to the new protocol of 10 × 4 Gy (group B), assigned on owners' informed consent. Statistical analysis was conducted under the "as treated" regime, using Kaplan-Meier and Cox-regression analysis. Treatment was delivered with technically advanced image-guided radiation therapy. The 2 treatment groups were compared in terms of outcome and signs of toxicosis. RESULTS: Overall progression-free interval (PFI) and overall survival (OS) time were favorable, with 663 (95%CI: 497;828) and 637 (95%CI: 403;870) days, respectively. We found no significant difference between the two groups: PFI for dogs in group A vs B was 608 (95%CI: 437;779) days and mean (median not reached) 863 (95%CI: 644;1083) days, respectively (P = .89), and OS for dogs in group A vs B 610 (95%CI: 404;816) and mean (median not reached) 796 (95%CI: 586;1007) days (P = .83). CONCLUSION AND CLINICAL IMPORTANCE: In conclusion, 10 × 4 Gy is a safe and efficient protocol for treatment of primary intracranial neoplasia and future dose escalation can be considered

    Recent advances in radiotherapy

    Get PDF
    Radiation therapy has come a long way from treatment planning based on orthogonal radiographs with large margins around tumours. Advances in imaging and radiation planning software have led to three-dimensional conformal radiotherapy and, further, to intensity modulated radiotherapy (IMRT). IMRT permits sparing of normal tissues and hence dose-escalation to tumours. IMRT is the current standard in treatment of head and prostate cancer and is being investigated in other tumour sites. Exquisitely sculpted dose distributions (increased geographical miss) with IMRT, plus tumour motion and anatomical changes during radiotherapy make image guided radiotherapy an essential part of modern radiation delivery. Various hardware and software tools are under investigation for optimal IGRT

    Determinants of fluoroscopy time for invasive coronary angiography and percutaneous coronary intervention: Insights from the NCDR ®

    Full text link
    Objectives Identifying the distributions and determinants of fluoroscopy time for invasive coronary angiography (ICA) and percutaneous coronary intervention (PCI). Background ICA and PCI are significant contributors to radiation exposure from medical imaging in the US. Fluoroscopy time is a potentially modifiable determinant of radiation exposure for these procedures, but has not been well characterized in contemporary practice. Methods We evaluated the distribution of fluoroscopy time in patients undergoing ICA and/or PCI in the CathPCI Registry ® , stratifying patients by numerous clinical scenarios. Hierarchical models were used to determine patient, procedure, operator and hospital‐level factors associated with fluoroscopy time for these procedures. Results Our study included a total of 3,295,348 ICA and PCI procedures performed by 9,600 operators from January 2005 through June 2009. There was wide variation in fluoroscopy times for these procedures with median [IQR] fluoroscopy times of 2.6 [1.7–4.5] minutes for ICA, 6.7 [4.2–10.8] minutes for ICA in patients with prior coronary artery bypass grafting (CABG), 10.1 [6.0–17.4] minutes for PCI, 10.7 [7.0–16.9] minutes for PCI with ICA, and 16.0 [10.6–24.0] minutes for PCI and ICA in patients with prior CABG. Prolonged fluoroscopy times (>30 minutes) were rare for ICA, but occurred in 6.7% of PCIs and 14.7% of PCIs in patients with prior CABG. After accounting for patient characteristics and procedure complexity, operator and hospital‐level factors explained nearly 20% of the variation in fluoroscopy time. Conclusions Fluoroscopy times vary widely during ICA and PCI with operator and hospital‐level factors contributing substantially to these differences. A better understanding of potentially modifiable sources of this variation will elucidate opportunities for enhancing the radiation safety of these procedures. © 2013 Wiley Periodicals, Inc.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/101860/1/ccd24996.pd
    corecore