6 research outputs found

    Betriebsbegleitende Lecksuche mit geloestem Tracergas in Fernwaermesystemen Abschlussbericht

    No full text
    The feasibility of in-service leak detection with dissolved tracer gas was investigated. Helium was selected as tracer gas because of its good diffusion characteristics, selective detectability at very low concentrations, inert and unproblematic behaviour within the district heating system, and good environmental compatibility. For a systematic investigation of the influencing parameters governing practical applications, a pipeline test field comprising about 240 m of KMR district heating pipelines and 61 controllable simulation leaks was constructed, and experiments using the new method were carried out. The required helium concentration amounts to a few grams of helium per cubic metre of district heating water. The water can be charged in the water preparation or feeding stage, and commercial detectors can be used. (orig./GL)Zur Entwicklung einer betriebsbegleitenden Lecksuchmethode fuer erdverlegte Rohrleitungen wurden in einem Feasbility-Test die Machbarkeit der Tracergassuche mittels geloestem Spuergas bestaetigt. Als Tracergas wurde Helium aufgrund seines guenstigen Diffusionsverhaltens, seiner selektiven Nachweisbarkeit bei kleinsten Konzentrationen, seines inerten, unproblematischen Verhaltens im Fernwaermenetz und seiner guten Umweltvertraeglichkeit ausgewaehlt. Zur systematischen Untersuchung der Einflussparameter bei der Anwendung der Methode unter praxisnahen Bedingungen wurde ein Rohrleitungsversuchsfeld mit ca. 240 m KMR-Fernwaermeleitung und 61 regelbaren Simulationsleckagen aufgebaut und die neue Lecksuchmethode eingehend experimentell getestet. Die einzustellende Heliumkonzentration im Fernwaermewasser ist mit wenigen Gramm Helium je Kubikmeter Fernwaermewasser gering. Eine Vorrichtung fuer die empfohlene Beladung des gesamten Netzwasserinhalts kann in Wasseraufbereitung oder Nachspeisung des Netzes eingebunden werden. Zur Detektion koennen, marktverfuegbare Messgeraete verwendet werden. (orig./GL)Available from TIB Hannover: F97B1602+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman

    Entwicklung eines umweltfreundlichen, energieextensiven Verfahrens zur Aufarbeitung von Prozesswaessern Abschlussbericht

    No full text
    Available from TIB Hannover: F99B1239 / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEDeutsche Bundesstiftung Umwelt, Osnabrueck (Germany)DEGerman

    Einmischen eines Reaktionsstoppers in hochviskose Fluessigkeiten Abschlussbericht

    No full text
    In the case of a failure in the cooling and the mixer drives, the control of chemcial reactors for exothermic reactions is problematic since the produced heat of reaction can't be removed sufficiently. In order to avoid the venting of the reactor content an inhibiting agent can be injected as a first line of defense. It is fed via a nozzle from a pressurized vessel without any further energy and can be mixed with the reactor content by momentum. The aim of this study was to investigate the mixing behaviour of the injected fluid with the reactor content in a technical plant and to improve the applicability of this safety system in a polymerization process of technical relevance. Therefore the inhibition mechanism and the efficiency of different inhibiting agents in a reaction calorimeter were studied. In addition the combined mixing and reaction process in a laboratory and two technical plants under various hydrodynamic and reaction conditions were investigated. Experiments and numerical simulations of the mixing process were performed by the variation of relevant parameters (geometric and fluid dynamic parameters, material data). The results were used to determine the distribution in the concentration of the inhibiting agent in the reactor, so that design methods and engineering guidelines for this safety system could be developed. The safety system was successfully tested in the explosion-proof plant for mass polymerization of styrene underrunaway conditions. (orig.)SIGLEAvailable from TIB Hannover: F97B473+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman

    Beherrschung kritischer Reaktionen in Mehrphasensystemen durch technische Massnahmen. T. 2: Zur sicherheitstechnischen Beurteilung von Semibatch-Prozessen mit Gas/Fluessigkeits-Systemen Abschlussbericht

    No full text
    In this project physical and process technological basics for the removal of scale layers on austenitic steels with CO_2-laser radiation have been worked out. Scales from hot rolling (15 #mu#m thickness) and TIG welding seams (1 #mu#m thickness) have been investigated. The most important results can be summarized as follows: A complete descaling is possible both with pulsed and continuous wave CO_2-laser radiation in case of an appropriate process management, the feed rate is approximately 9.5 cm"2/s for a laser power of 1600 W, the pitting potential as a measure for the corrosion resistance for the laser treated samples can be compared with that of pickled samples, the improved corrosion resistance results from the complete removal of the scale layers, the dissolution of the chromium carbides at the grain boundaries and from the formation of chromium oxides at the surface. The new technology is a promising alternative regarding processing quality and economic efficiency in dependence on the application. (orig.)Available from TIB Hannover: F96B1924+a / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEBundesministerium fuer Bildung, Wissenschaft, Forschung und Technologie, Bonn (Germany)DEGerman

    Pluralistische Waermeversorgung - Zeithorizont 2005. Strategien und Technologien einer pluralistischen Fern- und Nahwaermeversorgung in einem liberalisierten Energiemarkt unter besonderer Beruecksichtigung der Kraft-Waerme-Kopplung und erneuerbarer Energien AGFW-Studie. Schlussbericht

    No full text
    After developing the necessary methodological fundamentals for assessing cogeneration systems and making suggestions for maintenance and development strategies, the following aspects were investigated with a time horizon up to 2005: Analysis of the current market situation; Technology; Ecology; State of the art of cogeneration and district heating and industrial heat and power supply; Electricity rates in the current market adaption phase; Goals of national air pollution abatement; Assessment of cogeneration systems from the view of efficiency, cost and carbon dioxide emissions; Economic, ecological and energy supply related importance of cogeneration systems; Maintenance tools, obstacles to further market acceptance, recommendations for implementing appropriate measures for promoting cogeneration. A distinction should be made between short-term measures and longer-term measures which require longer preparationsIn dieser Vorstudie wurde zunaechst durch Analyse der Ausgangssituation die notwendige Basis hergestellt (s. Kapitel 2 bis 5 der Langfassung), um die verschiedenen Technologielinien der KWK zu bewerten und geeignete Strategien zu deren Erhalt und Ausbau empfehlen zu koennen. Im Einzelnen sollten hierbei folgende Aspekte mit einem Zeithorizont bis 2005 untersucht werden (vgl. Abbildung 1-2): - Analyse der Ausgangssituation Markt - Technik - Oekologie: heutiger Stand der Siedlungs-KWK und Fernwaerme sowie der industriellen Kraftwaermewirtschaft - die aktuelle Strompreisentwicklung in der Marktanpassungsphase - Ziele des nationalen Klimaschutzes. - Bewertung der KWK-Technologielinien unter Effizienz-, Kosten- und CO_2Emissions-Aspekten in der Marktanpassungsphase und ihrer laengerfristigen Perspektiven: technisch-oekonomisch (einzelwirtschaftliche Bewertung, Entwicklungspotentiale der KWK-Technik und der Fernwaerme) - technisch-oekologisch (potentieller Beitrag der KWK zu Zielen des Klimaschutzes, auch relativ zu anderen technischen Moeglichkeiten (Technologieranking)) - energiewirtschaftliche Bedeutung der KWK (u.a. Brennstoffdiversifikation, Komplementaertechnologie Fernwaerme fuer erneuerbare Energien) unter kurzfristigen Aspekten der CO_2-Emissionsminderung. - Erlaeuterung von Instrumenten zum Erhalt der KWK, Beschreibung von Hemmnissen und Marktunvollkommenheiten beim Ausbau der KWK und Formulierung einer Empfehlung zur Implementierung eines Massnahmenbuendels seitens geeigneter Akteure. Dabei sollte zwischen kurzfristig zu ergreifenden Massnahmen und solchen mit laengerem Vorbereitungsbedarf unterschieden werden. (orig.)Available from TIB Hannover: F01B89 / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekSIGLEBundesministerium fuer Bildung und Forschung, Berlin (Germany)DEGerman
    corecore