1,617 research outputs found

    X-ray sensor development for magnetospheric research

    Get PDF
    The ARPA-301 data on the P78-1 satellite provide information on the long-term X-ray environment; specifically, the distributions in total X-ray intensities and energy spectral parameters and the spatial extents of the X-ray sources. The average X-ray intensity near noontime was found to decrease with increasing local time whereas the opposite trend occurs around midnight. At both of these local times, the average flux increases with increasing level of geomagnetic activity. The distributions in flux are also considered for given local time intervals and these span a large dynamic range. The temporal correlation between the X-ray flux in different local time sectors is found to decrease with increasing difference in local time. The average spectral shapes do not depend significantly upon local time or geomagnetic activity

    The effects of the geosynchronous energetic particle radiation environment on spacecraft charging phenomena

    Get PDF
    The energetic electron environment at the geosynchronous orbit is responsible for a variety of adverse charging effects on spacecraft components. The most serious of these is the degradation and failure of a complementary-metal-oxide-semiconductor (CMOS) electronic components as a result of internal charge-buildup induced by the energetic electrons. Efforts to accurately determine the expected lifetime of these components in this orbit are hampered by the lack of detailed knowledge of the electron spectrum and intensity, particularly of the more penetrating energies greater than 1.5 MeV. This problem is illustrated through the calculation of the dose received by a CMOS device from the energetic electrons and associated bremsstrahlung as a function of aluminum shielding thickness using the NASA AE-6 and the Aerospace measured electron environments. Two computational codes which were found to be in good agreement were used to perform the calculations. For a given shielding thickness the dose received with the two radiation environments differ by as much as a factor of seven with a corresponding variation in lifetime of the CMOS

    Analysis of high resolution satellite data for cosmic gamma ray bursts

    Get PDF
    Cosmic gamma ray bursts detected a germanium spectrometer on the low altitude satellite 1972-076B were surveyed. Several bursts with durations ranging from approximately 0.032 to 15 seconds were found and are tabulated. The frequency of occurrence/intensity distribution of these events was compared with the S to the -3/2 power curve of confirmed events. The longer duration events fall above the S to the -3/2 power curve of confirmed events, suggesting they are perhaps not all true cosmic gamma-ray bursts. The narrow duration events fall closely on the S to the -3/2 power curve. The survey also revealed several counting rate spikes, with durations comparable to confirmed gamma-ray bursts, which were shown to be of magnetospheric origin. Confirmation that energetic electrons were responsible for these bursts was achieved from analysis of all data from the complete payload of gamma-ray and energetic particle detectors on board the satellite. The analyses also revealed that the narrowness of the spikes was primarily spatial rather than temporal in character

    Compton Gamma Ray Observatory/BATSE observations of energetic electrons scattered by cyclotron resonance with waves from powerful VLF transmitters

    Get PDF
    To obtain a better understanding of the wave-particle mechanisms responsible for the loss of electrons from the radiation belts, energetic electron data from the Burst and Transient Source Experiment (BATSE) on the NASA's Compton Gamma Ray Observatory (GRO) was studied. Powerful ground-based VLF transmitters resonantly scatter electrons from the inner radiation belt onto trajectories from which they precipitate into the atmosphere as they drift eastward. 563 instances in which the satellite traversed a cloud of energetic electrons which had been scattered into quasi-trapped trajectories were identified. From the longitude distribution, it was concluded that waves from the VLF transmitter NWC at 114 deg E are the origin of 257 of the events, and waves from UMSat 44 deg E related to 45 more. In another 177 cases the electrons had drifted from the longitude of these transmitters to a location in the western hemisphere. The previously reported seasonal variation in the frequency of occurrence of cyclotron resonance interaction is confirmed with the continuous coverage provided by GRO. The frequency of occurrence of the cyclotron resonance interactions is largest before sunrise, which we attribute to the diurnal variations in the transmission VLF waves through the ionosphere. For the first time, unique very narrow sheets of electrons occurring in the aftermath of a large geomagnetic storm are reported

    Compliance with the surgical safety checklist in Switzerland: an observational multicenter study based on self-reported data.

    Get PDF
    BACKGROUND Since publication of the surgical safety checklist by the WHO in 2009, it has been introduced in many hospitals. However, frequency and quality of surgical safety checklist use is often low probably limiting the effectiveness of the checklist in preventing patient harm. The focus of this study was to examine the current state of compliance with the surgical safety checklist in Switzerland and to evaluate how the data relates to international comparative data. METHODS Between November 2020 and March 2021 twelve hospitals with 15 sites collected for at least 200 surgical interventions each whether the three sections of the surgical safety checklist (Sign In, Team Time Out, Sign Out) have been applied. This data collection was part of a large quality improvement project focusing on measuring and improving compliance with the surgical safety checklist via peer observation and feedback. Descriptive statistics were used to analyze the data; chi-square tests were used to compare sub-samples. RESULTS The hospitals collected valid compliance data for 8622 surgical interventions. Mean compliance rate was 91% when distinguishing between the two categories applied (including partially applied) and not applied. In line with previous research, Sign In (93%) and Team Time Out (94%) sections have been applied more frequently than Sign Out (86%). All three surgical safety checklist sections have been applied in 79% of the surgical interventions, no sections in 1%. CONCLUSIONS The results of this study indicate that the overall application of the surgical safety checklist in Switzerland can be considered high, although the completeness, especially of the Sign Out section, could be improved. At present, it seems difficult to compare compliance rates from different studies as measurement methods and definitions of compliance vary widely. A systematization and homogenization of the methodology within, but also beyond, national borders is desirable for the future

    Kinetic pathways of the Nematic-Isotropic phase transition as studied by confocal microscopy on rod-like viruses

    Get PDF
    We investigate the kinetics of phase separation for a mixture of rodlike viruses (fd) and polymer (dextran), which effectively constitutes a system of attractive rods. This dispersion is quenched from a flow-induced fully nematic state into the region where the nematic and the isotropic phase coexist. We show experimental evidence that the kinetic pathway depends on the overall concentration. When the quench is made at high concentrations, the system is meta-stable and we observe typical nucleation-and-growth. For quenches at low concentration the system is unstable and the system undergoes a spinodal decomposition. At intermediate concentrations we see the transition between both demixing processes, where we locate the spinodal point.Comment: 11 pages, 6 figures, accepted in J. Phys.: Condens. Matter as symposium paper for the 6th Liquid Matter Conference in Utrech
    • …
    corecore