    Usefulness of Simple Diffusion Kurtosis Imaging for Head and Neck Tumors: An Early Clinical Study

    Get PDF
    Diffusion kurtosis (DK) imaging (DKI), a type of restricted diffusion-weighted imaging, has been reported to be useful for tumor diagnoses in clinical studies. We developed a software program to simultaneously create DK images with apparent diffusion coefficient (ADC) maps and conducted an initial clinical study. Multi-shot echo-planar diffusion-weighted images were obtained at b-values of 0, 400, and 800 sec/mm2 for simple DKI, and DK images were created simultaneously with the ADC map. The usefulness of the DK image and ADC map was evaluated using a pixel analysis of all pixels and a median analysis of the pixels of each case. Tumor and normal tissues differed significantly in both pixel and median analyses. In the pixel analysis, the area under the curve was 0.64 for the mean kurtosis (MK) value and 0.77 for the ADC value. In the median analysis, the MK value was 0.74, and the ADC value was 0.75. The MK and ADC values correlated moderately in the pixel analysis and strongly in the median analysis. Our simple DKI system created DK images simultaneously with ADC maps, and the obtained MK and ADC values were useful for differentiating head and neck tumors from normal tissue

    Quantitative evaluation of the reduction of distortion and metallic artifacts in magnetic resonance images using the multiacquisition variable‑resonance image combination selective sequence

    Get PDF
    Magnetic resonance imaging (MRI) is superior to computed tomography (CT) in determining changes in tissue structure, such as those observed following inflammation and infection. However, when metal implants or other metal objects are present, MRI exhibits more distortion and artifacts compared with CT, which hinders the accurate measurement of the implants. A limited number of reports have examined whether the novel MRI sequence, multiacquisition variable-resonance image combination selective (MAVRIC SL), can accurately measure metal implants without distortion. Therefore, the present study aimed to demonstrate whether MAVRIC SL could accurately measure metal implants without distortion and whether the area around the metal implants could be well delineated without artifacts. An agar phantom containing a titanium alloy lumbar implant was used for the present study and was imaged using a 3.0 T MRI machine. A total of three imaging sequences, namely MAVRIC SL, CUBE and magnetic image compilation (MAGiC), were applied and the results were compared. Distortion was evaluated by measuring the screw diameter and distance between the screws multiple times in the phase and frequency directions by two different investigators. The artifact region around the implant was examined using a quantitative method following standardization of the phantom signal values. It was revealed that MAVRIC SL was a superior sequence compared with CUBE and MAGiC, as there was significantly less distortion, a lack of bias between the two different investigators and significantly reduced artifact regions. These results suggested the possibility of utilizing MAVRIC SL for follow-up to observe metal implant insertions
    corecore