24 research outputs found

    Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center

    Get PDF
    Background Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect®) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. Methods A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Results Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). Conclusions FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician’s workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort

    ATHENA Research Book

    Get PDF
    The ATHENA European University is an alliance of nine Higher Education Institutions with the mission of fostering excellence in research and innovation by facilitating international cooperation. The ATHENA acronym stands for Advanced Technologies in Higher Education Alliance. The partner institutions are from France, Germany, Greece, Italy, Lithuania, Portugal, and Slovenia: the University of Orléans, the University of Siegen, the Hellenic Mediterranean University, the Niccolò Cusano University, the Vilnius Gediminas Technical University, the Polytechnic Institute of Porto, and the University of Maribor. In 2022 institutions from Poland and Spain joined the alliance: the Maria Curie-Skłodowska University and the University of Vigo. This research book presents a selection of the ATHENA university partners' research activities. It incorporates peer-reviewed original articles, reprints and student contributions. The ATHENA Research Book provides a platform that promotes joint and interdisciplinary research projects of both advanced and early-career researchers

    Die „tiefe Internationalisierung“ der deutschen Kommunikationswissenschaft?: Eine Evaluation der Personal- und Forschungsstrukturen sowie der Lehrprogramme deutscher Hochschulen

    Get PDF
    Der Beitrag präsentiert und diskutiert die Ergebnisse einer umfassenden Befragung und mehrerer Dokumentenanalysen zu Personal-und Forschungsstrukturen sowie Lehrprogrammen in der deutschen Kommunikationswissenschaft im Hinblick auf deren „tiefe Internationalisierung“ bzw. kosmopolitische Ausrichtung. Darunter verstehen wir eine umfassende Anerkennung und Einbindung globaler Vielfalt in die Wissensproduktion und messen dies entlang der Inhalts-und Raumdimension des Forschungs-und Lehroutputs der Professuren und der mit ihnen verbundenen Stellenstrukturen. Die Befunde zeigen, dass die deutsche Kommunikationswissenschaft einen großen Nachholbedarf hat, was eine kosmopolitische Wissensproduktion angeht. Vor dem Hintergrund der Relevanz globaler Werte, globalen Wissens und Global Governance werden aber auch Potentiale aufgezeigt sowie hochschulpolitische Maßnahmen diskutiert, die eine inhaltliche Internationalisierung der deutschen Kommunikationswissenschaft vorantreiben können.This paper presents and discusses the results of a comprehensive survey and several document analyses on personnel and research structures as well as teaching programs in German communication studies regarding their “deep internationalization” or cosmopolitan orientation. By this, we mean a comprehensive recognition and integration of global diversity into knowledge production. We measure this through the content and spatial dimension of the research and teaching output of professors, as well as the teaching and research staff linked tothem. The findings show that German communication studies is lagging a truly cosmopolitan knowledge production. Against the backdrop of the relevance of global values, global knowledge, and global governance, however, the study also points out potentials and discusses higher education policy measures that could advance the internationalization of German communication studies

    Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis.

    No full text
    OBJECTIVES:This investigation evaluated the effect of cochlear implant (CI) electrode length on speech comprehension in quiet and noise and compare the results with those of EAS users. METHODES:91 adults with some degree of residual hearing were implanted with a FLEX20, FLEX24, or FLEX28 electrode. Some subjects were postoperative electric-acoustic-stimulation (EAS) users; the other subjects were in the groups of electric stimulation-only (ES-only). Speech perception was tested in quiet and noise at 3 and 6 months of ES or EAS use. Speech comprehension results were analyzed and correlated to electrode length. RESULTS:While the FLEX20 ES and FLEX24 ES groups were still in their learning phase between the 3 to 6 months interval, the FLEX28 ES group was already reaching a performance plateau at the three months appointment yielding remarkably high test scores. EAS subjects using FLEX20 or FLEX24 electrodes outscored ES-only subjects with the same short electrodes on all 3 tests at each interval, reaching significance with FLEX20 ES and FLEX24 ES subjects on all 3 tests at the 3-months interval and on 2 tests at the 6- months interval. Amongst ES-only subjects at the 3- months interval, FLEX28 ES subjects significantly outscored FLEX20 ES subjects on all 3 tests and the FLEX24 ES subjects on 2 tests. At the-6 months interval, FLEX28 ES subjects still exceeded the other ES-only subjects although the difference did not reach significance. CONCLUSIONS:Among ES-only users, the FLEX28 ES users had the best speech comprehension scores, at the 3- months appointment and tendentially at the 6 months appointment. EAS users showed significantly better speech comprehension results compared to ES-only users with the same short electrodes

    Data from: Investigation of the effect of cochlear implant electrode length on speech comprehension in quiet and noise compared with the results with users of electro-acoustic-stimulation, a retrospective analysis

    No full text
    Objectives: This investigation evaluated the effect of cochlear implant (CI) electrode length on speech comprehension in quiet and noise and compare the results with those of EAS users. Methods: 91 adults with some degree of residual hearing were implanted with a FLEX20, FLEX24, or FLEX28 electrode. Some subjects were postoperative electric-acoustic-stimulation (EAS) users; the other subjects were in the groups of electric stimulation-only (ES-only). Speech perception was tested in quiet and noise at 3 and 6 months of ES or EAS use. Speech comprehension results were analyzed and correlated to electrode length. Results: While the FLEX20 ES and FLEX24 ES groups were still in their learning phase between the 3 to 6 months interval, the FLEX28 ES group was already reaching a performance plateau at the three months appointment yielding remarkably high test scores. EAS subjects using FLEX20 or FLEX24 electrodes outscored ES-only subjects with the same short electrodes on all 3 tests at each interval, reaching significance with FLEX20 ES and FLEX24 ES subjects on all 3 tests at the 3-months interval and on 2 tests at the 6- months interval. Amongst ES-only subjects at the 3- months interval, FLEX28 ES subjects significantly outscored FLEX20 ES subjects on all 3 tests and the FLEX24 ES subjects on 2 tests. At the-6 months interval, FLEX28 ES subjects still exceeded the other ES-only subjects although the difference did not reach significance. Conclusions: Among ES-only users, the FLEX28 ES users had the best speech comprehension scores, at the 3- months appointment and tendentially at the 6 months appointment. EAS users showed significantly better speech comprehension results compared to ES-only users with the same short electrodes