127 research outputs found

    Video Capsule Retention in a Zenker Diverticulum

    Get PDF
    We report the case of a video capsule endoscope lodged within a Zenker diverticulum. The system that was equipped with a real-time viewer showed an unchanging image unlike esophageal or gastric mucosa, suggesting that the capsule was elsewhere. The presence of cervical discomfort suggested video capsule retention in a Zenker diverticulum. The capsule was removed endoscopically and reinserted using a hood-assisted endoscope and the procedure was completed

    Capsule Endoscopy: A Valuable Tool in the Follow-Up of People With Celiac Disease on a Gluten-Free Diet

    Get PDF
    OBJECTIVES: Traditional celiac disease guidelines recommend follow-up endoscopy and duodenal biopsies at 6–12 months after commencing a gluten-free diet (GFD). However, histology may remain abnormal even 1–2 years later. We evaluated the role of capsule endoscopy in patients with celiac disease after treatment with a GFD. METHODS: Twelve adult patients with newly diagnosed celiac disease were prospectively enrolled. All patients had baseline symptom assessment, celiac serology (tissue transglutaminase antibody, tTG), and capsule endoscopy. Twelve months after commencing a GFD, patients underwent repeat symptom assessment, celiac serology, upper gastrointestinal endoscopy, and capsule endoscopy. RESULTS: At baseline, capsule endoscopy detected endoscopic markers of villous atrophy in the duodenum and extending to a variable distance along the small intestine. On the basis of small bowel transit time, the mean±s.e.m. percentage of small intestine with villous atrophy was 18.2±3.7%. After 12 months on a GFD, repeat capsule endoscopy demonstrated mucosal healing from a distal to proximal direction, and the percentage of small intestine with villous atrophy was significantly reduced to 3.4±1.2% (P¼0.0014) and this correlated with improvement in the symptom score (correlation 0.69, P¼0.01). There was a significant improvement in symptom score (5.2±1.0 vs. 1.7±0.4, P¼0.0012) and reduction in immunoglobulin A–tTG levels (81.5±10.6 vs. 17.5±8.2, P¼0.0005). However, 42% of subjects demonstrated persistent villous abnormality as assessed by duodenal histology. CONCLUSIONS: After 12 months on a GFD, patients with celiac disease demonstrate an improvement in symptoms, celiac serology, and the extent of disease as measured by capsule endoscopy. Mucosal healing occurs in a distal to proximal direction. The extent of mucosal healing correlates with improvement in symptoms. Duodenal histology does not reflect the healing that has occurred more distally.Ilmars Lidums, Edward Teo, John Field and Adrian G. Cummin

    Small bowel enteroclysis with magnetic resonance imaging and computed tomography in patients with failed and uncertain passage of a patency capsule

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Video capsule enteroscopy (VCE) has revolutionized small bowel imaging, enabling visual examination of the mucosa of the entire small bowel, while MR enteroclysis (MRE) and CT enteroclysis (CTE) have largely replaced conventional barium enteroclysis. A new indication for MRE and CTE is the clinical suspicion of small bowel strictures, as indicated by delayed or non-delivery of a test capsule given before a VCE examination, to exclude stenosis. The aim of this study was to determine the clinical value of subsequent MRE and CTE in patients in whom a test capsule did not present itself in due time.</p> <p>Methods</p> <p>Seventy-five consecutive patients were identified with a delayed or unnoticed delivery of the test capsule. Seventy patients consented to participate and underwent MRE (44) or CTE (26). The medical records and imaging studies were retrospectively reviewed and symptoms, laboratory results and imaging findings recorded.</p> <p>Results</p> <p>Lesions compatible with Crohns disease were shown by MRE in 5 patients, by CTE in one and by VCE in four, one of whom had lesions on MRE. In patients without alarm symptoms and findings (weight loss, haematochezia, anaemia, nocturnal diarrheoa, ileus, fistula, abscess and abnormal blood tests) imaging studies did not unveil any such lesion. VCE's were performed in only 20 patients, mainly younger than 50 years of age, although no stenotic lesion was shown by MRE and CTE. In the remaining 50 patients no VCE or other endoscopic intervention was performed indicating that the referring physician was content with the diagnostic information from MRE or CTE.</p> <p>Conclusion</p> <p>The diagnostic value of MRE and CTE is sufficient for clinical management of most patients with suspected small bowel disease, and thus VCE may be omitted or at least postponed for later usage.</p

    Improved detectability of small-bowel lesions via capsule endoscopy with computed virtual chromoendoscopy: A pilot study

    Get PDF
    Objective. Real-time video capsule endoscopy (CE) with flexible spectral imaging color enhancement (FICE) improves visibility of small-bowel lesions. This article aims to clarify whether CE-FICE also improves detectability of small-bowel lesions. Patients and methods. A total of 55 patients who underwent CE at Hiroshima University Hospital during the period November 2009 through March 2010 were enrolled in the study. Five patients were excluded from the study because residues and transit delays prevented sufficient evaluation. Thus, 50 patients participated. Two experienced endoscopists (each having interpreted more than 50 capsule videos) analyzed the images. One interpreted conventional capsule videos; the other, blinded to interpretation of the conventional images, interpreted CE-FICE images obtained at settings 1-3 (setting 1: red 595 nm, green 540 nm, blue 535 nm; setting 2: red 420 nm, green 520 nm, blue 530 nm; setting 3: red 595 nm, green 570 nm, blue 415 nm). Lesions were classified as angioectasia, erosion, ulceration, or tumor. Detectability was compared between the two modalities. Time taken to interpret the capsule videos was also determined. Results. Seventeen angioectasias were identified by conventional CE; 48 were detected by CE-FICE at setting 1, 45 at setting 2, and 24 at setting 3, with significant differences at settings 1 and 2 (p = 0.0003, p < 0.0001, respectively). Detection of erosion, ulceration, and tumor did not differ statistically between conventional CE and CE-FICE, nor did interpretation time (conventional CE 36 ± 6.9 min; CE-FICE setting 1, 36 ± 6.4 min; setting 2, 38 ± 5.8 min; setting 3, 35 ± 6.7 min). Conclusions. CE-FICE is superior in the lesion detection in comparison with conventional CE and improves detection of angioectasia

    Rebleeding rate after interventional therapy directed by capsule endoscopy in patients with obscure gastrointestinal bleeding

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The precise role of capsule endoscopy in the diagnostic algorithm of obscure gastrointestinal bleeding has yet to be determined. Despite the higher diagnostic yield of capsule endoscopy, the actual impact on clinical outcome remains poorly defined. The aim of this study was to evaluate the follow-up results of patients with obscure gastrointestinal bleeding to determine which management strategies after capsule endoscopy reduced rebleeding.</p> <p>Methods</p> <p>All patients in whom the cause of obscure gastrointestinal bleeding was investigated between May 2004 and March 2007 were studied retrospectively. We evaluated the clinical outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy using the rebleeding rate as the primary outcome.</p> <p>Results</p> <p>Seventy-seven patients with obscure gastrointestinal bleeding underwent capsule endoscopy. Capsule endoscopy identified clinically significant findings that were thought to be the sources of obscure gastrointestinal bleeding in 58.4% of the patients. The overall rebleeding rate was 36.4%. The rebleeding rate was significantly higher among patients with insignificant findings than among those with significant findings (<it>p </it>= 0.036). Among the patients in whom capsule endoscopy produced significant findings, the rebleeding rate of the patients who underwent therapeutic interventions was significantly lower than that in those who did not undergo intervention (9.5% vs 40.0%, <it>p </it>= 0.046).</p> <p>Conclusion</p> <p>Follow-up and further aggressive interventions are necessary for patients with obscure gastrointestinal bleeding and significant capsule endoscopy findings to reduce the chance of rebleeding.</p

    Real-Time In Vivo Imaging of Early Mucosal Changes during Ischemia-Reperfusion in Human Jejunum

    Get PDF
    BACKGROUND AND STUDY AIMS: Small intestinal ischemia-reperfusion (IR) is a frequent, potentially life threatening phenomenon. There is a lack of non-invasive diagnostic modalities. For many intestinal diseases, visualizing the intestinal mucosa using endoscopy is gold standard. However, limited knowledge exists on small intestinal IR-induced, early mucosal changes. The aims of this study were to investigate endoscopic changes in human jejunum exposed to IR, and to study concordance between endoscopic appearance and histology. PATIENTS AND METHODS: In 23 patients a part of jejunum, to be removed for surgical reasons, was isolated and selectively exposed to ischemia with 0, 30 or 120 minutes of reperfusion. In 3 patients, a videocapsule was inserted in the isolated segment before exposure to IR, to visualize the mucosa. Endoscopic view at several time points was related to histology (Heamatoxylin & Eosin) obtained from 20 patients. RESULTS: Ischemia was characterized by loss of villous structure, mucosal whitening and appearance of punctate lesions. This was related to appearance of subepithelial spaces and breaches in the epithelial lining in the histological view. Early during reperfusion, the lumen filled with IR-damaged, shed cells and VCE showed mucosal erosions, hemorrhage and intraluminal debris. At 60 minutes of reperfusion, the only remaining signs of IR were loss of villous structure and small erosions, indicating rapid mucosal healing. CONCLUSIONS: This study shows a unique, real-time in vivo endoscopic view of early mucosal changes during IR of the human small intestine. Future studies should evaluate its usefulness in diagnosis of patients suspected of IR

    Gastric transit and small intestinal transit time and motility assessed by a magnet tracking system

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Tracking an ingested magnet by the Magnet Tracking System MTS-1 (Motilis, Lausanne, Switzerland) is an easy and minimally-invasive method to assess gastrointestinal transit. The aim was to test the validity of MTS-1 for assessment of gastric transit time and small intestinal transit time, and to illustrate transit patterns detected by the system.</p> <p>Methods</p> <p>A small magnet was ingested and tracked by an external matrix of 16 magnetic field sensors (4 × 4) giving a position defined by 5 coordinates (position: <b>x, y, z, and angle: θ, ϕ)</b>. Eight healthy subjects were each investigated three times: (1) with a small magnet mounted on a capsule endoscope (PillCam); (2) with the magnet alone and the small intestine in the fasting state; and (3) with the magnet alone and the small intestine in the postprandial state.</p> <p>Results</p> <p>Experiment (1) showed good agreement and no systematic differences between MTS-1 and capsule endoscopy when assessing gastric transit (median difference 1 min; range: 0-6 min) and small intestinal transit time (median difference 0.5 min; range: 0-52 min). Comparing experiments (1) and (2) there were no systematic differences in gastric transit or small intestinal transit when using the magnet-PillCam unit and the much smaller magnetic pill. In experiments (2) and (3), short bursts of very fast movements lasting less than 5% of the time accounted for more than half the distance covered during the first two hours in the small intestine, irrespective of whether the small intestine was in the fasting or postprandial state. The mean contraction frequency in the small intestine was significantly lower in the fasting state than in the postprandial state (9.90 min<sup>-1 </sup>vs. 10.53 min<sup>-1</sup>) (p = 0.03).</p> <p>Conclusion</p> <p>MTS-1 is reliable for determination of gastric transit and small intestinal transit time. It is possible to distinguish between the mean contraction frequency of small intestine in the fasting state and in the postprandial state.</p
    corecore