88 research outputs found

    Global end-diastolic volume increases to maintain fluid responsiveness in sepsis-induced systolic dysfunction

    Get PDF
    Background: Sepsis-induced cardiac dysfunction may limit fluid responsiveness and the mechanism thereof remains unclear. Since cardiac function may affect the relative value of cardiac filling pressures, such as the recommended central venous pressure (CVP), versus filling volumes in guiding fluid loading, we studied these parameters as determinants of fluid responsiveness, according to cardiac function.Methods: A delta CVP-guided, 90 min colloid fluid loading protocol was performed in 16 mechanically ventilated patients with sepsis-induced hypotension and three 30 min consecutive fluid loading steps of about 450 mL per patient were evaluated. Global end-diastolic volume index (GEDVI), cardiac index (CI) and global ejection fraction (GEF) were assessed from transpulmonary dilution. Baseline and changes in CVP and GEDVI were compared among responding (CI increase ≥10% and ≥15%) and non-responding fluid loading steps, in patient with low (<20%, n = 9) and near-normal (≥20%) GEF (n = 7) at baseline.Results: A low GEF was in line with other indices of impaired cardiac (left ventricular) function, prior to and after fluid loading. Of 48 fluid loading steps, 9 (of 27) were responding when GEF <20% and 6 (of 21) when GEF ≥20. Prior to fluid loading, CVP did not differ between responding and non-responding steps and levels attained were 23 higher in the latter, regardless of GEF (P = 0.004). Prior to fluid loading, GEDVI (and CI) was higher in responding (1007 ± 306 mL/m2) than non-responding steps (870 ± 236 mL/m2) when GEF was low (P = 0.002), but did not differ when GEF was near-normal. Increases in GEDVI were associated with increases in CI and fluid responsiveness, regardless of GEF (P < 0.001).Conclusions: As estimated from transpulmonary dilution, about half of patients with sepsis-induced hypotension have systolic cardiac dysfunction. During dysfunction, cardiac dilation with a relatively high baseline GEDVI maintains fluid responsiveness by further dilatation (increase in GEDVI rather than of CVP) as in patients without dysfunction. Absence of fluid responsiveness during systolic cardiac dysfunction may be caused by diastolic dysfunction and/or right ventricular dysfunction

    Cardiac filling volumes versus pressures for predicting fluid responsiveness after cardiovascular surgery: the role of systolic cardiac function

    Get PDF
    ABSTRACT: INTRODUCTION: Static cardiac filling volumes have been suggested to better predict fluid responsiveness than filling pressures, but this may not apply to hearts with systolic dysfunction and dilatation. We evaluated the relative value of cardiac filling volume and pressures for predicting and monitoring fluid responsiveness, according to systolic cardiac function, estimated by global ejection fraction (GEF, normal 25 to 35%) from transpulmonary thermodilution. METHODS: We studied hypovolemic, mechanically ventilated patients after coronary (n = 18) or major vascular (n = 14) surgery in the intensive care unit. We evaluated 96 colloid fluid loading events (200 to 600 mL given in three consecutive 30-minute intervals, guided by increases in filling pressures), divided into groups of responding events (fluid responsiveness) and non-responding events, in patients with low GEF ( <20%) or near-normal GEF (≥20%). Patients were monitored by transpulmonary dilution and central venous (n = 9)/pulmonary artery (n = 23) catheters to obtain cardiac index (CI), global end-diastolic volume index (GEDVI), central venous (CVP) and pulmonary artery occlusion pressure (PAOP). RESULTS: Fluid responsiveness occurred in 8 (≥15% increase in CI) and 17 (≥10% increase in CI) of 36 fluid loading events when GEF was <20%, and 7 (≥15% increase in CI) and 17 (≥10% increase in CI) of 60 fluid loading events when GEF was ≥20%. Whereas a low baseline GEDVI predicted fluid responsiveness particularly when GEF was ≥20% (P = 0.002 or lower), a low PAOP was of predictive value particularly when GEF was <20% (P = 0.004 or lower). The baseline CVP was lower in responding events regardless of GEF. Changes in CVP and PAOP paralleled changes in CI particularly when GEF was <20%, whereas changes in GEDVI paralleled CI regardless of GEF. CONCLUSIONS: Regardless of GEF, CVP may be useful for predicting fluid responsiveness in patients after coronary and major vascular surgery provided that positive end-expiratory pressure is low. When GEF is low ( <20%), PAOP is more useful than GEDVI for predicting fluid responsiveness, but when GEF is near-normal (≥20%) GEDVI is more useful than PAOP. This favors predicting and monitoring fluid responsiveness by pulmonary artery catheter-derived filling pressures in surgical patients with systolic left ventricular dysfunction and by transpulmonary thermodilution-derived GEDVI when systolic left ventricular function is relatively norma

    Fractional Flow Reserve/ Instantaneous Wave-Free Ratio Discordance in Angiographically Intermediate Coronary Stenoses: An Analysis Using Doppler-Derived Coronary Flow Measurements

    Get PDF
    OBJECTIVES The study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR). BACKGROUND Discordance between FFR and iFR occurs in up to 20% of cases. No comparisons have been reported between the coronary flow characteristics of FFR/iFR discordant and angiographically unobstructed vessels. METHODS Baseline and hyperemic coronary flow velocity and coronary flow reserve (CFR) were compared across 5 vessel groups: FFRþ/iFRþ (108 vessels, n 1�4 91), FFR–/iFRþ (28 vessels, n 1�4 24), FFRþ/iFR– (22 vessels, n 1�4 22), FFR–/iFR– (208 vessels, n 1�4 154), and an unobstructed vessel group (201 vessels, n 1�4 153), in a post hoc analysis of the largest combined pressure and Doppler flow velocity registry (IDEAL [Iberian-Dutch-English] collaborators study). RESULTS FFRdisagreedwithiFRin14%(50of366).Baselineflowvelocitywassimilaracrossall5vesselgroups,includingthe unobstructed vessel group (p 1�4 0.34 for variance). In FFRþ/iFR– discordants, hyperemic flow velocity and CFR were similar to both FFR–/iFR– and unobstructed groups; 37.6 (interquartile range [IQR]: 26.1 to 50.4) cm/s vs. 40.0 [IQR: 29.7 to 52.3] cm/s and 42.2 [IQR: 33.8 to 53.2] cm/s and CFR 2.36 [IQR: 1.93 to 2.81] vs. 2.41 [IQR: 1.84 to 2.94] and 2.50 [IQR: 2.11 to 3.17], respectively (p > 0.05 for all). In FFR–/iFRþ discordants, hyperemic flow velocity, and CFR were similar to the FFRþ/iFRþ group; 28.2 (IQR: 20.5 to 39.7) cm/s versus 23.5 (IQR: 16.4 to 34.9) cm/s and CFR 1.44 (IQR: 1.29 to 1.85) versus 1.39 (IQR: 1.06 to 1.88), respectively (p > 0.05 for all). CONCLUSIONS FFR/iFR disagreement was explained by differences in hyperemic coronary flow velocity. Furthermore, coronary stenoses classified as FFRþ/iFR– demonstrated similar coronary flow characteristics to angiographically unobstructed vessels

    Incremental prognostic value of hybrid [15O]H2O positron emission tomography-computed tomography: combining myocardial blood flow, coronary stenosis severity, and high-risk plaque morphology

    Get PDF
    AimsThis study sought to determine the prognostic value of combined functional testing using positron emission tomography (PET) perfusion imaging and anatomical testing using coronary computed tomography angiography (CCTA)-derived stenosis severity and plaque morphology in patients with suspected coronary artery disease (CAD).Methods and resultsIn this retrospective study, 539 patients referred for hybrid [15O]H2O PET-CT imaging because of suspected CAD were investigated. PET was used to determine myocardial blood flow (MBF), whereas CCTA images were evaluated for obstructive stenoses and high-risk plaque (HRP) morphology. Patients were followed up for the occurrence of all-cause death and non-fatal myocardial infarction (MI). During a median follow-up of 6.8 (interquartile range 4.8–7.8) years, 42 (7.8%) patients experienced events, including 23 (4.3%) deaths, and 19 (3.5%) MIs. Annualized event rates for normal vs. abnormal results of PET MBF, CCTA-derived stenosis, and HRP morphology were 0.6 vs. 2.1%, 0.4 vs. 2.1%, and 0.8 vs. 2.8%, respectively (P ConclusionPET-derived MBF, CCTA-derived stenosis severity, and HRP morphology were univariably associated with death and MI, whereas only stenosis severity and HRP morphology provided independent prognostic value.</div
    corecore