179 research outputs found

    Nanolayered Diamond Sintered Compact Obtained by Direct Conversion from Highly Oriented Graphite under High Pressure and High Temperature

    Get PDF
    A new type of polycrystalline sintered diamond has been successfully synthesized by direct conversion from highly oriented pyrolytic graphite at 15 GPa and 2300°C. It is optically transparent and consists entirely of layered nanocrystals (50–100 nm thick) of cubic diamond, which are tightly bound to each other and have strong [111] preferred orientation along the stacking direction. This nanolayered diamond has excellent indentation hardness (~114 GPa in Knoop scale) comparable to the highest values obtained from single crystalline diamond. Furthermore, it is expected to have significantly high wear resistance on both ends of cylindrical sintered compact, since the surfaces are terminated exclusively by the hardest {111} planes of the layered diamond nanocrystals

    Electrocardiographic and electrophysiologic characteristics of ventricular tachycardia originating within the pulmonary artery

    Get PDF
    ObjectivesWe investigated the electrocardiographic (ECG) and electrophysiologic characteristics of ventricular tachycardia (VT) originating within the pulmonary artery (PA).BackgroundRadiofrequency catheter ablation (RFCA) is routinely applied to the endocardial surface of the right ventricular outflow tract (RVOT) in patients with idiopathic VT of left bundle branch block morphology. It was recently reported that this arrhythmia may originate within the PA.MethodsActivation mapping and ECG analysis were performed in 24 patients whose VTs or ventricular premature contractions (VPCs) were successfully ablated within the PA (PA group) and in 48 patients whose VTs or VPCs were successfully ablated from the endocardial surface of the RVOT (RV-end-OT group).ResultsR-wave amplitudes on inferior ECG leads, aVL/aVR ratio of Q-wave amplitude, and R/S ratio on lead V2were significantly larger in the PA group than in the RV-end-OT group. On intracardiac electrograms, atrial potentials were more frequently recorded in the PA group than in the RV-end-OT group (58% vs. 12%; p < 0.01). The amplitude of local ventricular potentials recorded during sinus rhythm within the PA was significantly lower than that recorded from the RV-end-OT (0.62 ± 0.56 mV vs. 1.55 ± 0.88 mV; p < 0.01).ConclusionsVentricular tachycardia originating within the PA has different electrocardiographic and electrophysiologic characteristics from that originating from the RV-end-OT. When mapping the RVOT area, the catheter may be located within the PA if a low-voltage atrial or local ventricular potential of <1-mV amplitude is recorded. Heightened attention must be paid if RFCA is required within the PA

    Effective Monotherapy with Amrubicin for a Refractory Extrapulmonary Small-Cell Carcinoma of the Liver

    Get PDF
    Small-cell carcinoma of the liver is a rare neoplasm, and no standard treatment for it has yet been established. A 72-year-old man with an extensive disease stage of small-cell carcinoma of the liver was treated with systemic chemotherapy consisting of cisplatin and etoposide (PE) followed by irinotecan. Although the masses were markedly decreased once after the sixth course of PE, amrubicin monotherapy as third-line chemotherapy was started because the hepatic masses had increased again. The administration of amrubicin was repeated in 8 courses with regression of the disease, resulting in a 26-month survival since the first-line chemotherapy was started. This is the first case report of a refractory EPSCC successfully treated with amrubicin

    Gastric cancer treatment in Japan: 2008 annual report of the JGCA nationwide registry

    Get PDF
    The Japanese Gastric Cancer Association (JGCA) started a new nationwide gastric cancer registry in 2008. Approximately 50 data items, including surgical procedures, pathological diagnoses, and survival outcomes, for 12004 patients with primary gastric cancer treated in 2001 were collected retrospectively from 187 participating hospitals. Data were entered into the JGCA database according to the JGCA Classification of gastric carcinoma, 13th edition and the International Union Against Cancer (UICC) TNM Classification of malignant tumors, 5th edition by using an electronic data collecting system. Finally, data of 11261 patients with gastric resection were analyzed. The 5-year follow-up rate was 83.5%. The direct death rate was 0.6%. TNM 5-year survival rates (5YSRs)/JGCA 5YSRs were 91.8/91.9% for stage IA, 84.6/85.1% for stage IB, 70.5/73.1% for stage II, 46.6/51.0% for stage IIIA, 29.9/33.4% for stage IIIB, and 16.6/15.8% for stage IV. The proportion of patients more than 80 years old was 7.0%, and their 5YSR was 48.7%. Compared to the JGCA archived data, though the follow-up rate needs to be improved, these data suggest that the postoperative results of patients with primary gastric carcinoma have improved in those with advanced disease and in the aged population in Japan

    Outburst of LS V+44 17 Observed by MAXI and RXTE, and Discovery of a Dip Structure in the Pulse Profile

    Full text link
    We report on the first observation of an X-ray outburst of a Be/X-ray binary pulsar LS V +44 17/RX J0440.9+4431, and the discovery of an absorption dip structure in the pulse profile. An outburst of this source was discovered by MAXI GSC in 2010 April. It was the first detection of the transient activity of LS V +44 17 since the source was identified as a Be/X-ray binary in 1997. From the data of the follow-up RXTE observation near the peak of the outburst, we found a narrow dip structure in its pulse profile which was clearer in the lower energy bands. The pulse-phase-averaged energy spectra in the 3-100 keV band can be fitted with a continuum model containing a power-law function with an exponential cutoff and a blackbody component, which are modified at low energy by an absorption component. A weak iron Kα\alpha emission line is also detected in the spectra. From the pulse-phase-resolved spectroscopy we found that the absorption column density at the dip phase was much higher than those in the other phases. The dip was not seen in the subsequent RXTE observations at lower flux levels. These results suggest that the dip in the pulse profile originates from the eclipse of the radiation from the neutron star by the accretion column.Comment: 18 pages, 7 figures, accepted for publication in PAS

    MAXI GSC observations of a spectral state transition in the black hole candidate XTE J1752-223

    Full text link
    We present the first results on the black hole candidate XTE J1752-223 from the Gas Slit Camera (GSC) on-board the Monitor of All-sky X-ray Image (MAXI) on the International Space Station. Including the onset of the outburst reported by the Proportional Counter Array on-board the Rossi X-ray Timing Explorer on 2009 October 23, the MAXI/GSC has been monitoring this source approximately 10 times per day with a high sensitivity in the 2-20 keV band. XTE J1752-223 was initially in the low/hard state during the first 3 months. An anti-correlated behavior between the 2-4 keV and 4-20 keV bands were observed around January 20, 2010, indicating that the source exhibited the spectral transition to the high/soft state. A transient radio jet may have been ejected when the source was in the intermediate state where the spectrum was roughly explained by a power-law with a photon index of 2.5-3.0. The unusually long period in the initial low/hard state implies a slow variation in the mass accretion rate, and the dramatic soft X-ray increase may be explained by a sudden appearance of the accretion disk component with a relatively low innermost temperature (0.4-0.7 keV). Such a low temperature might suggest that the maximum accretion rate was just above the critical gas evaporation rate required for the state transition.Comment: Publication of Astronomical Society of Japan Vol.62, No.5 (2010) [in print
    corecore