3 research outputs found

    A sensitive bioanalytical method development and validation of cabozantinib in human plasma by LC-ESI-MS/MS

    Get PDF
    A simple, sensitive and specific liquid chromatography–tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of cabozantinib (CZ) in human plasma using cabozantinib-d4 (CZD4) as an internal standard (IS). Chromatographic separation was performed on Xbridge C18, 50 x 4.6 mm, 5 mm column with an isocratic mobile phase composed of 10mM Ammonium formate and Methanol in the ratio of (20:80 v/v), at a flow-rate of 0.7 mL/min. CZ and CZD4 were detected with proton adducts at m/z 502.2 → 391.1 and 506.3 → 391.2 in multiple reaction monitoring (MRM) positive mode respectively. Liquid-Liquid extraction method was used to extract the drug and IS. The method was validated over a linear concentration range of 5.0-5000.0 pg/mL with correlation coefficient (r2 ) ≥ 0.9994. This method demonstrated intra and inter-day precision within 1.95 to 2.37 and 2.93 to 9.3 % and Accuracy within 101.4 to 102.4 and 99.5 to 104.8 %. Cabozantinib was found to be stable throughout freeze-thawing cycles, bench top and postoperative stability studies

    PHARMACOKINETIC INVESTIGATION OF REMOGLIFLOZIN IN RAT PLASMA SAMPLES BY HIGH-THROUGHPUT HPLC-MS-MS

    Get PDF
    Objective: Remogliflozin (REMO), a selective inhibitor of the renal sodium-dependent glucose transporter 2 channel, which could increase urine glucose excretion and lower plasma glucose in humans. To establish a simple, sensitive and completely validated HPLC-MS-MS approach for the analysis of Remogliflozin in rat plasma samples. Methods: The method was developed after simple step protein precipitation by acetonitrile and Empagliflozin (EMPA) was used as internal standard. Separation was done on an CORTECS C18, 90 Å, 2.7 µm, 4.6 mm X 150 mm with an isocratic mobile phase consisting of 0.1% Formic acid: acetonitrile (20:80%, v/v) and pumped at a flow stream of 0.8 ml/min at ambient temperature. Results: The approach developed showed fine calibration curve in the quantity range of 5-1000 pg/ml with correlation coefficient (r2) of ≥ 0.9997 and the intra-run accuracy and precision was 99.91 to 109.07% and 0.17 to 1.34, inter-run accuracy and precision was 99.8 to 101.54 and 0.17 to 1.66 according to FDA guidelines. Conclusion: The newly designed and validated approach was simple, fast and applied effectively for single-dose oral pharmacokinetic investigation in Wistar male rats for the quantification of REMO in biological matrix

    A sensitive bioanalytical method development and validation of cabozantinib in human plasma by LC-ESI-MS/MS

    Get PDF
    ABSTRACT A simple, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of cabozantinib (CZ) in human plasma using cabozantinib-d4 (CZD4) as an internal standard (IS). Chromatographic separation was performed on Xbridge C18, 50 x 4.6 mm, 5 mm column with an isocratic mobile phase composed of 10mM Ammonium formate and Methanol in the ratio of (20:80 v/v), at a flow-rate of 0.7 mL/min. CZ and CZD4 were detected with proton adducts at m/z 502.2 ® 391.1 and 506.3 ® 391.2 in multiple reaction monitoring (MRM) positive mode respectively. Liquid-Liquid extraction method was used to extract the drug and IS. The method was validated over a linear concentration range of 5.0-5000.0 pg/mL with correlation coefficient (r2) ≥ 0.9994. This method demonstrated intra and inter-day precision within 1.95 to 2.37 and 2.93 to 9.3 % and Accuracy within 101.4 to 102.4 and 99.5 to 104.8 %. Cabozantinib was found to be stable throughout freeze-thawing cycles, bench top and postoperative stability studies
    corecore