10 research outputs found

    Systematic review of reviews of intervention components associated with increased effectiveness in dietary and physical activity interventions.

    Get PDF
    BACKGROUND: To develop more efficient programmes for promoting dietary and/or physical activity change (in order to prevent type 2 diabetes) it is critical to ensure that the intervention components and characteristics most strongly associated with effectiveness are included. The aim of this systematic review of reviews was to identify intervention components that are associated with increased change in diet and/or physical activity in individuals at risk of type 2 diabetes. METHODS: MEDLINE, EMBASE, CINAHL, PsycInfo, and the Cochrane Library were searched for systematic reviews of interventions targeting diet and/or physical activity in adults at risk of developing type 2 diabetes from 1998 to 2008. Two reviewers independently selected reviews and rated methodological quality. Individual analyses from reviews relating effectiveness to intervention components were extracted, graded for evidence quality and summarised. RESULTS: Of 3856 identified articles, 30 met the inclusion criteria and 129 analyses related intervention components to effectiveness. These included causal analyses (based on randomisation of participants to different intervention conditions) and associative analyses (e.g. meta-regression). Overall, interventions produced clinically meaningful weight loss (3-5 kg at 12 months; 2-3 kg at 36 months) and increased physical activity (30-60 mins/week of moderate activity at 12-18 months). Based on causal analyses, intervention effectiveness was increased by engaging social support, targeting both diet and physical activity, and using well-defined/established behaviour change techniques. Increased effectiveness was also associated with increased contact frequency and using a specific cluster of "self-regulatory" behaviour change techniques (e.g. goal-setting, self-monitoring). No clear relationships were found between effectiveness and intervention setting, delivery mode, study population or delivery provider. Evidence on long-term effectiveness suggested the need for greater consideration of behaviour maintenance strategies. CONCLUSIONS: This comprehensive review of reviews identifies specific components which are associated with increased effectiveness in interventions to promote change in diet and/or physical activity. To maximise the efficiency of programmes for diabetes prevention, practitioners and commissioning organisations should consider including these components.RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are

    An observational study to assess if automated diabetic retinopathy image assessment software can replace one or more steps of manual imaging grading and to determine their cost-effectiveness.

    Get PDF
    BACKGROUND: Diabetic retinopathy screening in England involves labour-intensive manual grading of retinal images. Automated retinal image analysis systems (ARIASs) may offer an alternative to manual grading. OBJECTIVES: To determine the screening performance and cost-effectiveness of ARIASs to replace level 1 human graders or pre-screen with ARIASs in the NHS diabetic eye screening programme (DESP). To examine technical issues associated with implementation. DESIGN: Observational retrospective measurement comparison study with a real-time evaluation of technical issues and a decision-analytic model to evaluate cost-effectiveness. SETTING: A NHS DESP. PARTICIPANTS: Consecutive diabetic patients who attended a routine annual NHS DESP visit. INTERVENTIONS: Retinal images were manually graded and processed by three ARIASs: iGradingM (version 1.1; originally Medalytix Group Ltd, Manchester, UK, but purchased by Digital Healthcare, Cambridge, UK, at the initiation of the study, purchased in turn by EMIS Health, Leeds, UK, after conclusion of the study), Retmarker (version 0.8.2, Retmarker Ltd, Coimbra, Portugal) and EyeArt (Eyenuk Inc., Woodland Hills, CA, USA). The final manual grade was used as the reference standard. Arbitration on a subset of discrepancies between manual grading and the use of an ARIAS by a reading centre masked to all grading was used to create a reference standard manual grade modified by arbitration. MAIN OUTCOME MEASURES: Screening performance (sensitivity, specificity, false-positive rate and likelihood ratios) and diagnostic accuracy [95% confidence intervals (CIs)] of ARIASs. A secondary analysis explored the influence of camera type and patients' ethnicity, age and sex on screening performance. Economic analysis estimated the cost per appropriate screening outcome identified. RESULTS: A total of 20,258 patients with 102,856 images were entered into the study. The sensitivity point estimates of the ARIASs were as follows: EyeArt 94.7% (95% CI 94.2% to 95.2%) for any retinopathy, 93.8% (95% CI 92.9% to 94.6%) for referable retinopathy and 99.6% (95% CI 97.0% to 99.9%) for proliferative retinopathy; and Retmarker 73.0% (95% CI 72.0% to 74.0%) for any retinopathy, 85.0% (95% CI 83.6% to 86.2%) for referable retinopathy and 97.9% (95% CI 94.9 to 99.1%) for proliferative retinopathy. iGradingM classified all images as either 'disease' or 'ungradable', limiting further iGradingM analysis. The sensitivity and false-positive rates for EyeArt were not affected by ethnicity, sex or camera type but sensitivity declined marginally with increasing patient age. The screening performance of Retmarker appeared to vary with patient's age, ethnicity and camera type. Both EyeArt and Retmarker were cost saving relative to manual grading either as a replacement for level 1 human grading or used prior to level 1 human grading, although the latter was less cost-effective. A threshold analysis testing the highest ARIAS cost per patient before which ARIASs became more expensive per appropriate outcome than human grading, when used to replace level 1 grader, was Retmarker ÂŁ3.82 and EyeArt ÂŁ2.71 per patient. LIMITATIONS: The non-randomised study design limited the health economic analysis but the same retinal images were processed by all ARIASs in this measurement comparison study. CONCLUSIONS: Retmarker and EyeArt achieved acceptable sensitivity for referable retinopathy and false-positive rates (compared with human graders as reference standard) and appear to be cost-effective alternatives to a purely manual grading approach. Future work is required to develop technical specifications to optimise deployment and address potential governance issues. FUNDING: The National Institute for Health Research (NIHR) Health Technology Assessment programme, a Fight for Sight Grant (Hirsch grant award) and the Department of Health's NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital and the University College London Institute of Ophthalmology

    Perfecting Video Capsule Endoscopy: Is There Need for Training?

    No full text

    Diagnostic Yield and Clinical Impact of Video Capsule Endoscopy in Patients with Chronic Diarrhea: A Korean Multicenter CAPENTRY Study

    No full text
    BACKGROUND/AIMS: In some cases, chronic diarrhea is unexplained, and small bowel disorders may be one of the causes. The aim of this study was to assess the diagnostic yield and clinical impact of video capsule endoscopy (VCE) in patients with chronic diarrhea. METHODS: We retrospectively analyzed records from October 2002 to August 2013 in the VCE nationwide database registry (n=2,964). Ninety-one patients from 15 medical centers (60 males and 31 females; mean age, 47±19 years) were evaluated for VCE as a result of chronic diarrhea. RESULTS: The duration of chronic diarrhea was 8.3±14.7 months. The positive diagnostic yield of VCE was 42.9% (39/91). However, 15.4% (14/91) exhibited an inconsistent result, and 41.8% (38/91) were negative. Abnormal findings consistent with chronic diarrhea included erosions/aphthous ulcers (19.8%), ulcers (17.6%), mucosal erythema (3.3%), edema (1.1%), and luminal narrowing (1.1%). The most common diagnoses were functional diarrhea associated with irritable bowel syndrome in 37 patients (40.7%) and Crohn’s disease in 18 patients (19.8%). After VCE examination, the diagnosis was changed in 34.1% of the patients (31/91). Hematochezia (odds ratio [OR], 8.802; 95% confidence interval [CI], 2.126 to 36.441) and hypoalbuminemia (OR, 4.811; 95% CI, 1.241 to 18.655) are predictive factors of a positive diagnostic yield. CONCLUSIONS: VCE had a favorable diagnostic yield and clinical impact on the management of patients with chronic diarrhea
    corecore