62 research outputs found

    Thixotropy in macroscopic suspensions of spheres

    Get PDF
    An experimental study of the viscosity of a macroscopic suspension, i.e. a suspension for which Brownian motion can be neglected, under steady shear is presented. The suspension is prepared with a high packing fraction and is density-matched in a Newtonian carrier fluid. The viscosity of the suspension depends on the shear rate and the time of shearing. It is shown for the first time that a macroscopic suspension shows thixotropic viscosity, i.e. shear-thinning with a long relaxation time as a unique function of shear. The relaxation times show a systematic decrease with increasing shear rate. These relaxation times are larger when decreasing the shear rates, compared to those observed after increasing the shear. The time scales involved are about 10000 times larger than the viscous time scale and about 1000 times smaller than the thermodynamic time scale. The structure of the suspension at the outer cylinder of a viscometer is monitored with a camera, showing the formation of a hexagonal structure. The temporal decrease of the viscosity under shear coincides with the formation of this hexagonal pattern

    Estimating the risk of rabies transmission to humans in the U.S.: a delphi analysis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In the United States, the risk of rabies transmission to humans in most situations of possible exposure is unknown. Controlled studies on rabies are clearly not possible. Thus, the limited data on risk has led to the frequent administration of rabies post-exposure prophylaxis (PEP), often in inappropriate circumstances.</p> <p>Methods</p> <p>We used the Delphi method to obtain an expert group consensus estimate of the risk of rabies transmission to humans in seven scenarios of potential rabies exposure. We also surveyed and discussed the merits of recommending rabies PEP for each scenario.</p> <p>Results</p> <p>The median risk of rabies transmission without rabies PEP for a bite exposure by a skunk, bat, cat, and dog was estimated to be 0.05, 0.001, 0.001, and 0.00001, respectively. Rabies PEP was unanimously recommended in these scenarios. However, rabies PEP was overwhelmingly not recommended for non-bite exposures (e.g. dog licking hand but unavailable for subsequent testing), estimated to have less than 1 in 1,000,000 (0.000001) risk of transmission.</p> <p>Conclusions</p> <p>Our results suggest that there are many common situations in which the risk of rabies transmission is so low that rabies PEP should not be recommended. These risk estimates also provide a key parameter for cost-effective models of human rabies prevention and can be used to educate health professionals about situation-specific administration of rabies PEP.</p

    Microstructure and biomechanical characteristics of bone substitutes for trauma and orthopaedic surgery

    Get PDF
    Abstract. BACKGROUND: Many (artificial) bone substitute materials are currently available for use in orthopaedic trauma surgery. Objective data on their biological and biomechanical characteristics, which determine their clinical application, is mostly lacking. The aim of this study was to investigate structural and in vitro mechanical properties of nine bone substitute cements registered for use in orthopaedic trauma surgery in the Netherlands. METHODS: Seven calcium phosphate cements (BoneSource®, Calcibon®, ChronOS®, Eurobone®, HydroSet™, Norian SRS®, and Ostim®), one calcium sulphate cement (MIIG® X3), and one bioactive glass cement (Cortoss®) were tested. Structural characteristics were measured by micro-CT scanning. Compression strength and stiffness were determined following unconfined compression tests. RESULTS: Each bone substitute had unique characteristics. Mean total porosity ranged from 53% (Ostim®) to 0.5% (Norian SRS®). Mean pore size exceeded 100 μm only in Eurobone® and Cortoss® (162.2 ± 107.1 μm and 148.4 ± 70.6 μm, respectively). However, 230 μm pores were found in Calcibon®, Norian SRS®, HydroSet™, and MIIG® X3. Connectivity density ranged from 27/cm3 for HydroSet™ to 0.03/cm3 for Calcibon®. The ultimate compression strength was highest in Cortoss® (47.32 MPa) and lowest in Ostim® (0.24 MPa). Young's Modulus was highest in Calcibon® (790 MPa) and lowest in Ostim® (6 MPa). CONCLUSIONS: The bone substitutes tested display a wide range in structural properties and compression strength, indicating that they will be suitable for different clinical indications. The data outlined here will help surgeons to select the most suitable products currently available for specific clinical indications

    Effectiveness of career counseling and the impact of the working alliance.

    No full text
    This study analyzes the role of the working alliance on the life satisfaction and career decision difficulties of clients participating in career counseling in Switzerland. The study also compares these career counseling clients to a group of students who did not seek counseling, to explore the overall effectiveness of a face-to-face career counseling intervention, using a pre-post design. Results indicated that the working alliance was positively associated with clients' satisfaction with the intervention and with the final level of their life satisfaction. Working alliance was also negatively associated with the final levels of career decision difficulties. Moreover, clients' career decision difficulties significantly decreased and their life satisfaction increased throughout the intervention. These findings suggest that working alliance represents an important variable to better understand career interventions' underlying mechanisms. Moreover, face-to-face career counseling is effective considering career-specific as well as broader, life-related indicators
    corecore