1 research outputs found

    Π‘Ρ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹ΠΉ Π°Π½Π°Π»ΠΈΠ· диагностичСской цСнности систСм ΠΊΠΎΠΌΠΏΡŒΡŽΡ‚Π΅Ρ€Π½ΠΎΠ³ΠΎ Π°Π½Π°Π»ΠΈΠ·Π° ΠΌΠ°ΠΌΠΌΠΎΠ³Ρ€Π°ΠΌΠΌ I ΠΈ II ΠΏΠΎΠΊΠΎΠ»Π΅Π½ΠΈΠΉ

    Get PDF
    Aim: to compare the diagnostic efficacy of generationΒ I and II computer aided detection (CAD) systems for mammographyΒ of our own design using the large set of unselect ed mammography images obtained in a routine clinical practice settings.Β Material and methods. Both CADs were tested on theΒ set of 1532 mammography images of 356 women with confirmedΒ breast cancer (BC). We assessed their value in theΒ detection of suspicious areas with various characteristicsΒ located on the different density background. Size of BCΒ lesions varied from 4 to 35 mm (mean – 13,4 Β± 6,3 mm).Β We excluded BC representing only with microcalcificationΒ clusters from this analysis, because this task is solved usingΒ the separate universal module compatible with both CADs.Results. For I and II generation CADs we obtained theΒ following results: detection of small nodular BCs (≀10 mm) – 41 of 52 (78.85%) and 48 of 52 (92.31%; p > 0.05), respectively;Β detection of BCs visible as asymmetric areas – 18 ofΒ 18 (100%) and 13 of 18 (72.2%; p > 0.05), respectively;Β detection of only partially visible masses – 15 of 18 (83.3%)Β and 17 of 18 (94.4%; p > 0.05); detection of lesions poorlyΒ visible or invisible on standard mammography imagesΒ due to the high density background (C-D types according toΒ the ACR 2013 classification) – 9 of 16 (56.3%) and 7 of 16Β (70.0%; p = 0.046). Total detection rate was 88.76% (316 ofΒ 356 cases) – for CAD I and 90.73% (323 of 356 cases;Β Ρ€ > 0.05) – for CAD II. Mean false positive marks rate wasΒ 1.8 and 1.3 per image, respectively, – for ACR А-Π’ imagesΒ and 2.6 and 1.8 per image, respectively – for ACR C-DΒ images (p < 0.05).Conclusion. Generally the diagnostic value of CAD II isΒ not inferior that of CAD I in all analyzed situations, except theΒ poorly visible or invisible lesions on the dense breast background.Β Moreover, CAD II is probably superior CAD I in theΒ detection of spiculated small masses. The rate of falseΒ positive marks was significantly higher for CAD I.ЦСль исслСдования: ΡΡ€Π°Π²Π½ΠΈΡ‚Π΅Π»ΡŒΠ½Π°Ρ ΠΎΡ†Π΅Π½ΠΊΠ° эффСктивности Ρ€Π°Π±ΠΎΡ‚Ρ‹ систСм ΠΊΠΎΠΌΠΏΡŒΡŽΡ‚Π΅Ρ€Π½ΠΎΠ³ΠΎ Π°Π½Π°Π»ΠΈΠ·Π° (CAD)Β I ΠΈ II ΠΏΠΎΠΊΠΎΠ»Π΅Π½ΠΈΠΉ собствСнной Ρ€Π°Π·Ρ€Π°Π±ΠΎΡ‚ΠΊΠΈ Π½Π° ΠΎΠ±ΡˆΠΈΡ€Π½ΠΎΠΉΒ Π±Π°Π·Π΅ Π½Π΅ΠΎΡ‚ΠΎΠ±Ρ€Π°Π½Π½Ρ‹Ρ… маммографичСских ΠΈΠ·ΠΎΠ±Ρ€Π°ΠΆΠ΅Π½ΠΈΠΉ,Β ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Π½Ρ‹Ρ… Π² условиях Ρ€ΡƒΡ‚ΠΈΠ½Π½ΠΎΠΉ клиничСской ΠΏΡ€Π°ΠΊΡ‚ΠΈΠΊΠΈ.ΠœΠ°Ρ‚Π΅Ρ€ΠΈΠ°Π» ΠΈ ΠΌΠ΅Ρ‚ΠΎΠ΄Ρ‹. ОбС систСмы Π±Ρ‹Π»ΠΈ протСстированы Π½Π° Π½Π°Π±ΠΎΡ€Π΅ ΠΈΠ· 1532 ΠΌΠ°ΠΌΠΌΠΎΠ³Ρ€Π°ΠΌΠΌ 356 пациСнток с Π²Π΅Ρ€ΠΈΡ„ΠΈΡ†ΠΈΡ€ΠΎΠ²Π°Π½Π½Ρ‹ΠΌ Ρ€Π°ΠΊΠΎΠΌ ΠΌΠΎΠ»ΠΎΡ‡Π½ΠΎΠΉ ΠΆΠ΅Π»Π΅Π·Ρ‹ (Π ΠœΠ–)Β Π½Π° ΡΠΏΠΎΡΠΎΠ±Π½ΠΎΡΡ‚ΡŒ ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠΈΠ²Π°Ρ‚ΡŒ ΠΏΠΎΠ΄ΠΎΠ·Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Π΅ области с Ρ€Π°Π·Π»ΠΈΡ‡Π½Ρ‹ΠΌΠΈ характСристиками Π½Π° ΠΌΠ°ΠΌΠΌΠΎΠ³Ρ€Π°ΠΌΠΌΠ°Ρ… Ρ€Π°Π·Π»ΠΈΡ‡Π½ΠΎΠΉ стСпСни плотности. Π Π°Π·ΠΌΠ΅Ρ€ ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉ, ΡΠΎΠΎΡ‚Π²Π΅Ρ‚ΡΡ‚Π²ΠΎΠ²Π°Π²ΡˆΠΈΡ… Π ΠœΠ–, Π²Π°Ρ€ΡŒΠΈΡ€ΠΎΠ²Π°Π» ΠΎΡ‚ 4 Π΄ΠΎ 35 ΠΌΠΌ (срСдний – 13,4 Β± 6,3 ΠΌΠΌ). Π˜ΡΠΊΠ»ΡŽΡ‡Π°Π»ΠΈ случаи Π ΠœΠ–, ΠΏΡ€ΠΎΡΠ²Π»ΡΠ²ΡˆΠΈΠ΅ΡΡ Ρ‚ΠΎΠ»ΡŒΠΊΠΎ Π² Π²ΠΈΠ΄Π΅ скоплСний ΠΌΠΈΠΊΡ€ΠΎΠΊΠ°Π»ΡŒΡ†ΠΈΠ½Π°Ρ‚ΠΎΠ²,Β ΠΏΠΎΡΠΊΠΎΠ»ΡŒΠΊΡƒ данная Π·Π°Π΄Π°Ρ‡Π° Ρ€Π΅ΡˆΠ°Π΅Ρ‚ΡΡ с ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½ΠΈΠ΅ΠΌΒ ΠΎΡ‚Π΄Π΅Π»ΡŒΠ½ΠΎΠ³ΠΎ ΡƒΠ½ΠΈΠ²Π΅Ρ€ΡΠ°Π»ΡŒΠ½ΠΎΠ³ΠΎ Π±Π»ΠΎΠΊΠ°.Π Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹. ΠŸΡ€ΠΈ использовании систСм I ΠΈ II поколСния Π±Ρ‹Π»ΠΈ ΠΏΠΎΠ»ΡƒΡ‡Π΅Π½Ρ‹ ΡΠ»Π΅Π΄ΡƒΡŽΡ‰ΠΈΠ΅ Ρ€Π΅Π·ΡƒΠ»ΡŒΡ‚Π°Ρ‚Ρ‹ соотвСтствСнно: ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½ΠΈΠ΅ ΠΌΠ°Π»Ρ‹Ρ… Ρ€Π°ΠΊΠΎΠ² (Π΄ΠΎ 10 ΠΌΠΌ) с очаговым ростом – 41 (78,85%) ΠΈΠ· 52 ΠΈ 48 (92,31%; p > 0,05) ΠΈΠ· 52;Β ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½ΠΈΠ΅ Π ΠœΠ–, ΠΏΡ€ΠΎΡΠ²Π»ΡΡŽΡ‰Π΅Π³ΠΎΡΡ Π² Π²ΠΈΠ΄Π΅ асиммСтрии, – 18 (100%) ΠΈΠ· 18 ΠΈ 13 (72,2%; p > 0,05) ΠΈΠ· 18; ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½ΠΈΠ΅ частично срСзанных ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉ – 15 (83,3%)Β ΠΈΠ· 18 ΠΈ 17 (94,4%; p > 0,05) ΠΈΠ· 18; ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½ΠΈΠ΅ ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉ, ΠΏΠ»ΠΎΡ…ΠΎ Π²ΠΈΠ΄ΠΈΠΌΡ‹Ρ… ΠΈΠ»ΠΈ Π²ΠΎΠΎΠ±Ρ‰Π΅ Π½Π΅Π²ΠΈΠ΄ΠΈΠΌΡ‹Ρ… Π½Π° стандартных ΠΌΠ°ΠΌΠΌΠΎΠ³Ρ€Π°ΠΌΠΌΠ°Ρ… Π²Π²ΠΈΠ΄Ρƒ ΠΏΠ»ΠΎΡ‚Π½ΠΎΠΉ ΠΏΠ°Ρ€Π΅Π½Ρ…ΠΈΠΌΡ‹ ΠœΠ–Β (Ρ‚ΠΈΠΏΡ‹ C-D согласно ACR 2013), – 9 (56,3%) ΠΈΠ· 16 ΠΈΒ 7 (70,0%; p = 0,046) ΠΈΠ· 16. ΠžΠ±Ρ‰Π°Ρ частота ΠΎΠ±Π½Π°Ρ€ΡƒΠΆΠ΅Π½ΠΈΡΒ ΠΏΠΎΠ΄ΠΎΠ·Ρ€ΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉ составила 88,76% (316 ΠΈΠ·Β 356 случаСв) – для CAD I ΠΈ 90,73% (323 ΠΈΠ· 356 случаСв;Β Ρ€>0,05) – для CAD II. Частота Π»ΠΎΠΆΠ½ΠΎΠΏΠΎΠ»ΠΎΠΆΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ…Β ΠΌΠ΅Ρ‚ΠΎΠΊ составила Π² срСднСм 1,8 ΠΈ 1,3 соотвСтствСнно Π½Π°Β ΠΌΠ°ΠΌΠΌΠΎΠ³Ρ€Π°ΠΌΠΌΡƒ ΠΏΡ€ΠΈ Ρ‚ΠΈΠΏΠ°Ρ… ACR А–В ΠΈ 2,6 ΠΈ 1,8 соотвСтствСнно – ΠΏΡ€ΠΈ Ρ‚ΠΈΠΏΠ°Ρ… ACR C–D (p < 0,05).Π’Ρ‹Π²ΠΎΠ΄Ρ‹. Π­Ρ„Ρ„Π΅ΠΊΡ‚ΠΈΠ²Π½ΠΎΡΡ‚ΡŒ CAD II сравнима с Ρ‚Π°ΠΊΠΎΠ²ΠΎΠΉΒ CAD I Π²ΠΎ всСх ситуациях, Π·Π° ΠΈΡΠΊΠ»ΡŽΡ‡Π΅Π½ΠΈΠ΅ΠΌ выявлСния ΠΏΠ»ΠΎΡ…ΠΎΒ Π²ΠΈΠ΄ΠΈΠΌΡ‹Ρ… ΠΈ Π½Π΅Π²ΠΈΠ΄ΠΈΠΌΡ‹Ρ… ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉ вслСдствиС ΠΏΠ»ΠΎΡ‚Π½ΠΎΠΉΒ ΠΏΠ°Ρ€Π΅Π½Ρ…ΠΈΠΌΡ‹ ΠœΠ–. ΠšΡ€ΠΎΠΌΠ΅ Ρ‚ΠΎΠ³ΠΎ, CAD II, вСроятно, прСвосходит CAD I Π² выявлСнии спикулизированных ΠΎΠ±Ρ€Π°Π·ΠΎΠ²Π°Π½ΠΈΠΉΒ ΠΌΠ°Π»Ρ‹Ρ… Ρ€Π°Π·ΠΌΠ΅Ρ€ΠΎΠ². Частота Π»ΠΎΠΆΠ½ΠΎΠΏΠΎΠ»ΠΎΠΆΠΈΡ‚Π΅Π»ΡŒΠ½Ρ‹Ρ… ΠΌΠ΅Ρ‚ΠΎΠΊ ΠΏΡ€ΠΈΒ ΠΈΡΠΏΠΎΠ»ΡŒΠ·ΠΎΠ²Π°Π½ΠΈΠΈ CAD I Π±Ρ‹Π»Π° достовСрно Π²Ρ‹ΡˆΠ΅
    corecore