98 research outputs found

    Early Detection of Emotional and Behavioural Problems in Preschool Children:

    Get PDF
    __Abstract__ Psychosocial problems are already prevalent in very young children. Early detection of such problems is important because it improves the prognosis. One instrument that is developed for the early detection of psychosocial problems and delay in competencies is the Brief Infant-Toddler Social and Emotional Assessment (BITSEA). This study had two main objectives: 1) evaluating the psychometric properties of the BITSEA, and 2) assessing whether psychosocial well-being was better when the BITSEA was applied during the well-child visit, compared to care as usual (i.e. the application of an instrument intended to guide the conversation between parent and child health professional; the KIPPPI). The studies described in this thesis indicate that the BITSEA is a questionnaire with adequate psychometric properties. It appeared that children experience fewer psychosocial problems when the BITSEA was used as compared to care as usual at one-year follow-up. These findings support the BITSEA as a useful instrument, for the application in preventive child health care in the Netherlands, to detect psychosocial problems at an early age and in an early stage

    Swept-3-D Ultrasound Imaging of the Mouse Brain Using a Continuously Moving 1-D-Array-Part I:Doppler Imaging

    Get PDF
    Volumetric 3-D Doppler ultrasound imaging can be used to investigate large scale blood dynamics outside of the limited view that conventional 2-D power Doppler images (PDIs) provide. To create 3-D PDIs, 2-D-matrix array transducers can be used to insonify a large volume for every transmission; however, these matrices suffer from low sensitivity, high complexity, and high cost. More typically, a 1-D-Array transducer is used to scan a series of stationary 2-D PDIs, after which a 3-D volume is created by concatenating the 2-D PDIs in postprocessing, which results in long scan times due to repeated measurements. Our objective was to achieve volumetric 3-D Doppler ultrasound imaging with a high Doppler sensitivity, similar to that of a typical stationary recording using a 1-D-Array transducer, while being more affordable than using 2-D-matrix arrays. We achieved this by mounting a 1-D-Array transducer to a high-precision motorized linear stage and continuously translating over the mouse brain in a sweeping manner. For Part I of this article, we focused on creating the best vascular images by investigating how to best combine filtered beamformed ultrasound frames, which were not acquired at the same spatial locations, into PDIs. Part II focuses on the implications of sampling transient brain hemodynamics through functional ultrasound (fUS) while continuously translating over the mouse brain. In Part I, we show how the speed at which we sweep our 1-D-Array transducer affects the Doppler spectrum in a flow phantom. In vivo recordings were performed on the mouse brain while varying the sweeping speed, showing how higher sweeping speeds negatively affect the PDI quality. A weighting vector is found to combine frames while continuously moving over the mouse brain, allowing us to create swept PDIs of similar sensitivity when compared with those obtained using a stationary 1-D-Array while allowing a significantly higher 3-D Doppler volume rate and maintaining the benefits of having a low computational and monetary cost. We show that a vascular subvolume of 6 mm can be scanned in 2.5 s, with a PDI reconstructed every 200μm200 \mu \text{m} , outperforming classical staged recording methods.</p

    Swept-3D Ultrasound Imaging of the Mouse Brain Using a Continuously Moving 1D-Array Part II:Functional Imaging

    Get PDF
    Functional ultrasound (fUS) using a 1-D-array transducer normally is insufficient to capture volumetric functional activity due to being restricted to imaging a single brain slice at a time. Typically, for volumetric fUS, functional recordings are repeated many times as the transducer is moved to a new location after each recording, resulting in a nonunique average mapping of the brain response and long scan times. Our objective was to perform volumetric 3-D fUS in an efficient and cost-effective manner. This was achieved by mounting a 1-D-array transducer to a high-precision motorized linear stage and continuously translating over the mouse brain in a sweeping manner. We show how the speed at which the 1-D-array is translated over the brain affects the sampling of the hemodynamic response (HR) during visual stimulation as well as the quality of the resulting power Doppler image (PDI). Functional activation maps were compared between stationary recordings, where only one functional slice is obtained for every recording, and our swept-3-D method, where volumetric fUS was achieved in a single functional recording. The results show that the activation maps obtained with our method closely resemble those obtained during a stationary recording for that same location, while our method is not restricted to functional imaging of a single slice. Lastly, a mouse brain subvolume of 6 mm is scanned at a volume rate of 1.5 s per volume, with a functional PDI reconstructed every 200\mu \text{m} , highlighting swept-3-D's potential for volumetric fUS. Our method provides an affordable alternative to volumetric fUS using 2-D-matrix transducers, with a high SNR due to using a fully sampled 1-D-array transducer, and without the need to repeat functional measurements for every 2-D slice, as is most often the case when using a 1-D-array. This places our swept-3-D method as a potentially valuable addition to conventional 2-D fUS, especially when investigating whole-brain functional connectivity, or when shorter recording durations are desired.</p

    Swept-3D Ultrasound Imaging of the Mouse Brain Using a Continuously Moving 1D-Array Part II:Functional Imaging

    Get PDF
    Functional ultrasound (fUS) using a 1-D-array transducer normally is insufficient to capture volumetric functional activity due to being restricted to imaging a single brain slice at a time. Typically, for volumetric fUS, functional recordings are repeated many times as the transducer is moved to a new location after each recording, resulting in a nonunique average mapping of the brain response and long scan times. Our objective was to perform volumetric 3-D fUS in an efficient and cost-effective manner. This was achieved by mounting a 1-D-array transducer to a high-precision motorized linear stage and continuously translating over the mouse brain in a sweeping manner. We show how the speed at which the 1-D-array is translated over the brain affects the sampling of the hemodynamic response (HR) during visual stimulation as well as the quality of the resulting power Doppler image (PDI). Functional activation maps were compared between stationary recordings, where only one functional slice is obtained for every recording, and our swept-3-D method, where volumetric fUS was achieved in a single functional recording. The results show that the activation maps obtained with our method closely resemble those obtained during a stationary recording for that same location, while our method is not restricted to functional imaging of a single slice. Lastly, a mouse brain subvolume of 6 mm is scanned at a volume rate of 1.5 s per volume, with a functional PDI reconstructed every 200\mu \text{m} , highlighting swept-3-D's potential for volumetric fUS. Our method provides an affordable alternative to volumetric fUS using 2-D-matrix transducers, with a high SNR due to using a fully sampled 1-D-array transducer, and without the need to repeat functional measurements for every 2-D slice, as is most often the case when using a 1-D-array. This places our swept-3-D method as a potentially valuable addition to conventional 2-D fUS, especially when investigating whole-brain functional connectivity, or when shorter recording durations are desired.</p

    Screening for autism spectrum disorders with the brief infant-toddler social and emotional assessment

    Get PDF
    Objective: Using parent-completed questionnaires in (preventive) child health care can facilitate the early detection of psychosocial problems and psychopathology, including autism spectrum disorders (ASD). A promising questionnaire for this purpose is the Brief Infant-Toddler Social and Emotional Assessment (BITSEA). The screening accuracy with regard to ASD of the BITSEA Problem and Competence scales and a newly calculated Autism score were evaluated. Method: Data, that was collected between April 2010 and April 2011, from a community sample of 2-year-olds (N = 3127), was combined with a sample of preschool children diagnosed with ASD (N = 159). For the total population and for subgroups by child's gender, area under the Receiver Operating Characteristic (ROC) curve was examined, and across a range of BITSEA Problem, Competence and Autism scores, sensitivity, specificity, positive and negative likelihood ratio's, diagnostic odds ratio and Youden's index were reported. Results: The area under the ROC curve (95% confidence interval, [95%CI]) of the Problem scale was 0.90(0.87-0.92), of the Competence scale 0.93(0.91-0.95), and of the Autism score 0.95(0.93-0.97). For the total population, the screening accuracy of the Autism score was significantly better, compared to the Problem scale. The screening accuracy of the Competence scale was significantly better for girls (AUC = 0.97; 95%CI = 0.95-0.98) than for boys (AUC = 0.91; 95%CI = 0.88-0.94). Conclusion: The results indicate that the BITSEA scales and newly calculated Autism score have good discriminative power to differentiate children with and without ASD. Therefore, the BITSEA may be helpful in the early detection of ASD, which could have beneficial effects on the child's development

    Four-Dimensional Computational Ultrasound Imaging of Brain Haemodynamics

    Full text link
    Four-dimensional ultrasound imaging of complex biological systems such as the brain is technically challenging because of the spatiotemporal sampling requirements. We present computational ultrasound imaging (cUSi), a new imaging method that uses complex ultrasound fields that can be generated with simple hardware and a physical wave prediction model to alleviate the sampling constraints. cUSi allows for high-resolution four-dimensional imaging of brain haemodynamics in awake and anesthetized mice

    Reliability and Validity of the Dutch Version of the Brief Infant-Toddler Social and Emotional Assessment (BITSEA)

    Get PDF
    Background: The Brief Infant-Toddler Social and Emotional Assessment (BITSEA) is a relatively new and short (42-item) questionnaire that measures psychosocial problems in toddlers and consists of a Problem and a Competence scale. In this study the reliability and validity of the Dutch version of the BITSEA were examined for the whole group and for gender and ethnicity subgroups. Methods: Parents of 7140 two-year-old children were invited in the study, of which 3170 (44.4%) parents completed the BITSEA. For evaluation of the score distribution, the presence of floor/ceiling effects was determined. The internal consistency (Cronbach's alpha) was evaluated and in subsamples the test-retest, parent-childcare provider interrater reliability and concurrent validity with regard to the Child Behavioral Checklist (CBCL). Discriminative validity was evaluated by comparing scores of parents that worry and parents that do not worry about their child's development. Results: The BITSEA showed no floor or ceiling effects. Psychometric properties of the BITSEA Problem and Competence scale were respectively: Cronbach's alphas were 0.76 and 0.63. Test-retest correlations were 0.75 and 0.61. Interrater reliability correlations were 0.30 and 0.17. Concurrent validity was as hypothesised. The BITSEA was able to discriminate between parents that worry about their child and parents that do not worry. The psychometric properties of the BITSEA were comparable across gender and ethnic background. Conclusion: The results in this large-scale study of a diverse sample support the reliability and validity of the BITSEA Problem scale. The BITSEA Competence scale needs further study. The performance of the BITSEA appears to be similar in subgroups by gender and ethnic background

    Case report: High-resolution, intra-operative µDoppler-imaging of spinal cord hemangioblastoma

    Get PDF
    Surgical resection of spinal cord hemangioblastomas remains a challenging endeavor: the neurosurgeon’s aim to reach total tumor resections directly endangers their aim to minimize post-operative neurological deficits. The currently available tools to guide the neurosurgeon’s intra-operative decision-making consist mostly of pre-operative imaging techniques such as MRI or MRA, which cannot cater to intra-operative changes in field of view. For a while now, spinal cord surgeons have adopted ultrasound and its submodalities such as Doppler and CEUS as intra-operative techniques, given their many benefits such as real-time feedback, mobility and ease of use. However, for highly vascularized lesions such as hemangioblastomas, which contain up to capillary-level microvasculature, having access to higher-resolution intra-operative vascular imaging could potentially be highly beneficial. µDoppler-imaging is a new imaging modality especially fit for high-resolution hemodynamic imaging. Over the last decade, µDoppler-imaging has emerged as a high-resolution, contrast-free sonography-based technique which relies on High-Frame-Rate (HFR)-ultrasound and subsequent Doppler processing. In contrast to conventional millimeter-scale (Doppler) ultrasound, the µDoppler technique has a higher sensitivity to detect slow flow in the entire field-of-view which allows for unprecedented visualization of blood flow down to sub-millimeter resolution. In contrast to CEUS, µDoppler is able to image high-resolution details continuously, without being contrast bolus-dependent. Previously, our team has demonstrated the use of this technique in the context of functional brain mapping during awake brain tumor resections and surgical resections of cerebral arteriovenous malformations (AVM). However, the application of µDoppler-imaging in the context of the spinal cord has remained restricted to a handful of mostly pre-clinical animal studies. Here we describe the first application of µDoppler-imaging in the case of a patient with two thoracic spinal hemangioblastomas. We demonstrate how µDoppler is able to identify intra-operatively and with high-resolution, hemodynamic features of the lesion. In contrast to pre-operative MRA, µDoppler could identify intralesional vascular details, in real-time during the surgical procedure. Additionally, we show highly detailed post-resection images of physiological human spinal cord anatomy. Finally, we discuss the necessary future steps to push µDoppler to reach actual clinical maturity

    Approaches to assess IgE mediated allergy risks (sensitization and cross-reactivity) from new or modified dietary proteins

    Get PDF
    The development and introduction of new dietary protein sources has the potential to improve food supply sustainability. Understanding the potential allergenicity of these new or modified proteins is crucial to ensure protection of public health. Exposure to new proteins may result in de novo sensitization, with or without clinical allergy, or clinical reactions through cross-reactivity. In this paper we review the potential of current methodologies (in silico, in vitro degradation, in vitro IgE binding, animal models and clinical studies) to address these outcomes for risk assessment purposes for new proteins, and especially to identify and characterise the risk of sensitization for IgE mediated allergy from oral exposure. Existing tools and tests are capable of assessing potential crossreactivity. However, there are few possibilities to assess the hazard due to de novo sensitization. The only methods available are in vivo models, but many limitations exist to use them for assessing risk. We conclude that there is a need to understand which criteria adequately define allergenicity for risk assessment purposes, and from these criteria develop a more suitable battery of tests to distinguish between proteins of high and low allergenicity, which can then be applied to assess new proteins with unknown risks. © 2017 The Authors Chemicals/CAS: immunoglobulin E, 37341-29-

    Testing the proficiency to distinguish locations with elevated plantar pressure within and between professional groups of foot therapists

    Get PDF
    BACKGROUND: Identification of locations with elevated plantar pressures is important in daily foot care for patients with rheumatoid arthritis, metatarsalgia and diabetes. The purpose of the present study was to evaluate the proficiency of podiatrists, pedorthists and orthotists, to distinguish locations with elevated plantar pressure in patients with metatarsalgia. METHODS: Ten podiatrists, ten pedorthists and ten orthotists working in The Netherlands were asked to identify locations with excessively high plantar pressure in three patients with forefoot complaints. Therapists were instructed to examine the patients according to the methods used in their everyday clinical practice. Regions could be marked through hatching an illustration of a plantar aspect. A pressure sensitive platform was used to quantify the dynamic bare foot plantar pressures and was considered as 'Gold Standard' (GS). A pressure higher than 700 kPa was used as cut-off criterion for categorizing peak pressure into elevated or non-elevated pressure. This was done for both patient's feet and six separate forefoot regions: big toe and metatarsal one to five. Data were analysed by a mixed-model ANOVA and Generalizability Theory. RESULTS: The proportions elevated/non-elevated pressure regions, based on clinical ratings of the therapists, show important discrepancies with the criterion values obtained through quantitative plantar pressure measurement. In general, plantar pressures in the big toe region were underrated and those in the metatarsal regions were overrated. The estimated method agreement on clinical judgement of plantar pressures with the GS was below an acceptable level: i.e. all intraclass correlation coefficient's equal or smaller than .60. The inter-observer agreement for each discipline demonstrated worrisome results: all below .18. The estimated mutual agreements showed that there was virtually no mutual agreement between the professional groups studied. CONCLUSION: Identification of elevated plantar pressure through clinical evaluation is difficult, insufficient and may be potentially harmful. The process of clinical plantar pressure screening has to be re-evaluated. The results of this study point towards the merit of quantitative plantar pressure measurement for clinical practice
    • …
    corecore