332 research outputs found
Investigation of Geant4 Simulation of Electron Backscattering
A test of Geant4 simulation of electron backscattering recently published in
this journal prompted further investigation into the causes of the observed
behaviour. An interplay between features of geometry and physics algorithms
implemented in Geant4 is found to significantly affect the accuracy of
backscattering simulation in some physics configurations
Validation Test of Geant4 Simulation of Electron Backscattering
Backscattering is a sensitive probe of the accuracy of electron scattering
algorithms implemented in Monte Carlo codes. The capability of the Geant4
toolkit to describe realistically the fraction of electrons backscattered from
a target volume is extensively and quantitatively evaluated in comparison with
experimental data retrieved from the literature. The validation test covers the
energy range between approximately 100 eV and 20 MeV, and concerns a wide set
of target elements. Multiple and single electron scattering models implemented
in Geant4, as well as preassembled selections of physics models distributed
within Geant4, are analyzed with statistical methods. The evaluations concern
Geant4 versions from 9.1 to 10.1. Significant evolutions are observed over the
range of Geant4 versions, not always in the direction of better compatibility
with experiment. Goodness-of-fit tests complemented by categorical analysis
tests identify a configuration based on Geant4 Urban multiple scattering model
in Geant4 version 9.1 and a configuration based on single Coulomb scattering in
Geant4 10.0 as the physics options best reproducing experimental data above a
few tens of keV. At lower energies only single scattering demonstrates some
capability to reproduce data down to a few keV. Recommended preassembled
physics configurations appear incapable of describing electron backscattering
compatible with experiment. With the support of statistical methods, a
correlation is established between the validation of Geant4-based simulation of
backscattering and of energy deposition
Quantitative Test of the Evolution of Geant4 Electron Backscattering Simulation
Evolutions of Geant4 code have affected the simulation of electron
backscattering with respect to previously published results. Their effects are
quantified by analyzing the compatibility of the simulated electron
backscattering fraction with a large collection of experimental data for a wide
set of physics configuration options available in Geant4. Special emphasis is
placed on two electron scattering implementations first released in Geant4
version 10.2: the Goudsmit-Saunderson multiple scattering model and a single
Coulomb scattering model based on Mott cross section calculation. The new
Goudsmit-Saunderson multiple scattering model appears to perform equally or
less accurately than the model implemented in previous Geant4 versions,
depending on the electron energy. The new Coulomb scattering model was flawed
from a physics point of view, but computationally fast in Geant4 version 10.2;
the physics correction released in Geant4 version 10.2p01 severely degrades its
computational performance. Evolutions in the Geant4 geometry domain have
addressed physics problems observed in electron backscattering simulation in
previous publications.Comment: To be published in IEEE Trans. Nucl. Sc
Charge-spin correlation in van der Waals antiferromagenet NiPS3
Strong charge-spin coupling is found in a layered transition-metal
trichalcogenide NiPS3, a van derWaals antiferromagnet, from our study of the
electronic structure using several experimental and theoretical tools:
spectroscopic ellipsometry, x-ray absorption and photoemission spectroscopy,
and density-functional calculations. NiPS3 displays an anomalous shift in the
optical spectral weight at the magnetic ordering temperature, reflecting a
strong coupling between the electronic and magnetic structures. X-ray
absorption, photoemission and optical spectra support a self-doped ground state
in NiPS3. Our work demonstrates that layered transition-metal trichalcogenide
magnets are a useful candidate for the study of correlated-electron physics in
two-dimensional magnetic material.Comment: 6 pages, 3 figur
Effects of Glycyrrhizae Radix Pharmacopuncture Intravenous Injection on Ischemia-induced Acute Renal Failure in Rabbits
Objectives: The present study was undergone to determine whether Glycyrrhizae Radix pharmacopuncture intravenous injection exerts beneficial effect against the ischemia-induced acute renal failure in rabbits.
Methods: Rabbits were treated with Glycyrrhizae Radix pharmacopuncture via i.v., followed by renal ischemia/reperfusion. The fractional excretion of glucose and phosphate were measured and the malondialdehyde content was also determined. The morphological changes of cortical part of kidney also observed with light microscope.
Results: Renal ischemia/reperfusion caused increase of the fractional excretion of glucose and phosphate in ischemia-induced animals, which was prevented by Radix Glycyrrhizae extract treatment. Ischemia/reperfusion increased lipid peroxidation, which was prevented and morphological changes also altered by Radix Glycyrrhizae pharmacopuncture administration.
Conclusions: These results indicate that lipid peroxidation plays a critical role in ischemia-induced acute renal failure and Glycyrrhizae Radix pharmacopuncture exerts the protective effect against acute renal failure induced by renal ischemia/reperfusion
Elevated Neutrophil to Lymphocyte Ratio Predicts Poor Prognosis in Non-muscle Invasive Bladder Cancer Patients: Initial Intravesical Bacillus Calmette-Guerin Treatment After Transurethral Resection of Bladder Tumor Setting
The objective of this study was to investigate pretreatment systemic inflammatory response (SIR) markers in patients who underwent initial intravesical treatment for high-risk non-muscle invasive bladder cancer (NMIBC). A total of 385 patients who underwent initial intravesical Bacillus Calmette-Guerin treatment after transurethral resection of bladder tumor (TURB) were included. We analyzed the relationship between oncological outcomes and ratios of SIR markers, including neutrophil-to-lymphocyte ratio (NLR), derived neutrophil-to-lymphocyte ratio (dNLR), and platelet-to-lymphocyte ratio (PLR). Each SIR marker was used for analysis. Their cut-off values were determined through receiver operation characteristics curves analysis. Patients were divided into two groups according to pretreatment NLR (<1.5 vs. â„1.5), dNLR (<1.2 vs. â„1.2), and PLR values (171< vs. â„171). Patients with NLR â„ 1.5 and dNLR â„ 1.2 were associated with poor prognosis in terms of overall survival and cause-specific survival. However, no serum SIR marker was associated with prognosis in recurrence-free survival or progression-free survival. Cox multivariate analysis revealed that age, NLR, dNLR, hemoglobin, and pathologic T stage were significant factors predicting overall survival. Age, NLR, and pathologic T stage were significant factors predicting cancer-specific survival, NLR and tumor number were the most important predictors of bladder preserving survival. NLR before treatment was correlated with both oncological outcomes and survival outcome in NMIBC patients undergoing initial intravesical BCG treatment after TURB. Increased NLR reflects a poor prognosis of these outcomes
- âŠ