1,202 research outputs found

    Alignment of the amino terminal amino acid sequence of human cytochrome c oxidase subunits I and II with the sequence of their putative mRNAs

    Get PDF
    Thirteen of the first fifteen amino acids from the NH2-terminus of the primary sequence of human cytochrome c oxidase subunit I and eleven of the first twelve amino acids of subunit II have been identified by microsequencing procedures. These sequences have been compared with the recently determined 5'-end proximal sequences of the HeLa cell mitochondrial mRNAS and unambiguously aligned with two of them. This alignment has allowed the identification of the putative mRNA for subunit I, and has shown that the initiator codon for this subunit is only three nucleotides away from the 5'-end of its mRNA; furthermore, the results have substantiated the idea that the translation of human cytochrome c oxidase subunit II starts directly at the 5'-end of its putative mRNA, as had been previously inferred on the basis of the sequence homology of human mitochondrial DNA with the primary sequence of the bovine subunit

    Isolation and amino acid sequence analysis of a 4,000-dalton dynorphin from porcine pituitary

    Get PDF
    A 4,000-dalton dynorphin was isolated from porcine pituitary. It has 32 amino acids (Mr = 3,986), with the previously described heptadecapeptide (now called dynorphin A) at its amino terminus and a related tridecapeptide, dynorphin B, at its carboxyl terminus. The two peptides are separated by the "processing signal" Lys-Arg

    Biologic activity in a fragment of recombinant human interferon α

    Get PDF
    To attempt to locate functionally important regions of the interferon (IFN) molecule, recombinant human IFN-α2 was subjected to proteolytic digestion. The bacterial proteinase thermolysin produced two major complementary fragments, HuIFN-α2-(1-110) and HuIFN-α2-(111-153). After reduction with 2-mercaptoethanol and separation of the two major fragments on NaDodSO4/polyacrylamide gel electrophoresis, antiviral activity persisted in the larger, Mr 12,000, fragment consisting of the amino-terminal 110 amino acids

    Ionization behavior of the histidine residue in the catalytic triad of serine proteases

    Get PDF
    α-Lytic protease is a homologue of the mammalian serine proteases such as trypsin, chymotrypsin, and elastase, and its single histidine residue belongs to the Asp-His-Ser catalytic triad. This single histidine residue has been selectively enriched in the C-2 carbon with 13C. Magnetic resonance studies of the chemical shift and coupling constant (1Jch) behavior of this nucleus as a function of pH suggest that the imidazole ring is neutral above pH 5 and therefore that the group which is known to ionize with pKa near 6.7 must be the aspartic acid residue. Implications of these new pKa assignments for the catalytic mechanism of serine proteases are discussed and include the absence of any need to separate charge during catalysis. The histidine residue plays two roles. (a) It insulates the aspartic acid from an aqueous environment and accordingly raises its pKa. (b) It serves as a bidentate base to accept a proton from the serine at one of its nitrogens and concertedly transfer a proton from its other nitrogen to the buried carboxylate anion during formation of the tetrahedral intermediate

    A gas-liquid solid phase peptide and protein sequenator

    Get PDF
    A new miniaturized protein and peptide sequenator has been constructed which uses gas phase reagents at the coupling and cleavage steps of the Edman degradation. The sample is embedded in a matrix of Polybrene dried onto a porous glass fiber disc located in a small cartridge-style reaction cell. The protein or peptide, though not covalently attached to the support, is essentially immobile throughout the degradative cycle, since only relatively apolar, liquid phase solvents pass through the cell. This instrument can give useful sequence data on as little as 5 pmol or protein, can perform extended sequence runs (greater than 30 residues) on subnanomole quantities of proteins purified by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, and can sequence hydrophobic peptides to completion. The sequenator is characterized by a high repetitive yield during the degradation, low reagent consumption, low maintenance requirements, and a degradative cycle time of only 50 min using a complete double cleavage program

    Comparison of exon 5 sequences from 35 class I genes of the BALB/c mouse

    Get PDF
    DNA sequences of the fifth exon, which encodes the transmembrane domain, were determined for the BALB/c mouse class I MHC genes and used to study the relationships between them. Based on nucleotide sequence similarity, the exon 5 sequences can be divided into seven groups. Although most members within each group are at least 80% similar to each other, comparison between groups reveals that the groups share little similarity. However, in spite of the extensive variation of the fifth exon sequences, analysis of their predicted amino acid translations reveals that only four class I gene fifth exons have frameshifts or stop codons that terminate their translation and prevent them from encoding a domain that is both hydrophobic and long enough to span a lipid bilayer. Exactly 27 of the remaining fifth exons could encode a domain that is similar to those of the transplantation antigens in that it consists of a proline-rich connecting peptide, a transmembrane segment, and a cytoplasmic portion with membrane-anchoring basic residues. The conservation of this motif in the majority of the fifth exon translations in spite of extensive variation suggests that selective pressure exists for these exons to maintain their ability to encode a functional transmembrane domain, raising the possibility that many of the nonclassical class I genes encode functionally important products

    High Throughput MicroRNA Profiling: Optimized Multiplex qRT-PCR at Nanoliter Scale on the Fluidigm Dynamic ArrayTM IFCs

    Get PDF
    The broad involvement of miRNAs in critical processes underlying development, tissue homoeostasis and disease has led to a surging interest among the research and pharmaceutical communities. To study miRNAs, it is essential that the quantification of microRNA levels is accurate and robust. By comparing wild-type to small RNA deficient mouse embryonic stem cells (mESC), we revealed a lack of accuracy and robustness in previous published multiplex qRT-PCR techniques. Here, we describe an optimized method, including purifying away excessive primers from previous multiplex steps before singleplex real time detection, which dramatically increases the accuracy and robustness of the technique. Furthermore, we explain how performing the technique on a microfluidic chip at nanoliter volumes significantly reduces reagent costs and permits time effective high throughput miRNA expression profiling

    Large scale real-time PCR validation on gene expression measurements from two commercial long-oligonucleotide microarrays

    Get PDF
    BACKGROUND: DNA microarrays are rapidly becoming a fundamental tool in discovery-based genomic and biomedical research. However, the reliability of the microarray results is being challenged due to the existence of different technologies and non-standard methods of data analysis and interpretation. In the absence of a "gold standard"/"reference method" for the gene expression measurements, studies evaluating and comparing the performance of various microarray platforms have often yielded subjective and conflicting conclusions. To address this issue we have conducted a large scale TaqMan(® )Gene Expression Assay based real-time PCR experiment and used this data set as the reference to evaluate the performance of two representative commercial microarray platforms. RESULTS: In this study, we analyzed the gene expression profiles of three human tissues: brain, lung, liver and one universal human reference sample (UHR) using two representative commercial long-oligonucleotide microarray platforms: (1) Applied Biosystems Human Genome Survey Microarrays (based on single-color detection); (2) Agilent Whole Human Genome Oligo Microarrays (based on two-color detection). 1,375 genes represented by both microarray platforms and spanning a wide dynamic range in gene expression levels, were selected for TaqMan(® )Gene Expression Assay based real-time PCR validation. For each platform, four technical replicates were performed on the same total RNA samples according to each manufacturer's standard protocols. For Agilent arrays, comparative hybridization was performed using incorporation of Cy5 for brain/lung/liver RNA and Cy3 for UHR RNA (common reference). Using the TaqMan(® )Gene Expression Assay based real-time PCR data set as the reference set, the performance of the two microarray platforms was evaluated focusing on the following criteria: (1) Sensitivity and accuracy in detection of expression; (2) Fold change correlation with real-time PCR data in pair-wise tissues as well as in gene expression profiles determined across all tissues; (3) Sensitivity and accuracy in detection of differential expression. CONCLUSION: Our study provides one of the largest "reference" data set of gene expression measurements using TaqMan(® )Gene Expression Assay based real-time PCR technology. This data set allowed us to use an alternative gene expression technology to evaluate the performance of different microarray platforms. We conclude that microarrays are indeed invaluable discovery tools with acceptable reliability for genome-wide gene expression screening, though validation of putative changes in gene expression remains advisable. Our study also characterizes the limitations of microarrays; understanding these limitations will enable researchers to more effectively evaluate microarray results in a more cautious and appropriate manner
    • …
    corecore