34 research outputs found

    The Role of a Bioengineered Artificial Kidney in Renal Failure

    Full text link
    Renal failure continues to carry substantial burden of morbidity and mortality in both acute and chronic forms, despite advances in transplantation and dialysis. There is evidence to suggest that the kidney has metabolic, endocrine, and immune effects transcending its filtration functions, even beyond secretion of renin and erythropoietin. Our laboratory has developed experience in the tissue culture of renal parenchymal cells, and has now been able to demonstrate the metabolic activity of these cells in an extracorporeal circuit recapitulating glomerulotubular anatomy. We have observed active transport of sodium, glucose, and glutathione. We describe the design and initial preclinical testing of the bioartificial kidney, as well as future directions of our research.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/71995/1/j.1749-6632.2001.tb03841.x.pd

    Development of a wearable bioartificial kidney using the Bioartificial Renal Epithelial Cell System (BRECS)

    Full text link
    Cell therapy for the treatment of renal failure in the acute setting has proved successful, with therapeutic impact, yet development of a sustainable, portable bioartificial kidney for treatment of chronic renal failure has yet to be realized. Challenges in maintaining an anticoagulated blood circuit, the typical platform for solute clearance and support of the biological components, have posed a major hurdle in advancement of this technology. This group has developed a Bioartificial Renal Epithelial Cell System (BRECS) capable of differentiated renal cell function while sustained by body fluids other than blood. To evaluate this device for potential use in endâ stage renal disease, a large animal model was established that exploits peritoneal dialysis fluid for support of the biological device and delivery of cell therapy while providing uraemic control. Anephric sheep received a continuous flow peritoneal dialysis (CFPD) circuit that included a BRECS. Sheep were treated with BRECS containing 1 à  108 renal epithelial cells or acellular sham devices for up to 7 days. The BRECS cell viability and activity were maintained with extracorporeal peritoneal fluid circulation. A systemic immunological effect of BRECS therapy was observed as cellâ treated sheep retained neutrophil oxidative activity better than shamâ treated animals. This model demonstrates that use of the BRECS within a CFPD circuit embodies a feasible approach to a sustainable and effective wearable bioartificial kidney. Copyright © 2016 John Wiley & Sons, Ltd.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/140038/1/term2206.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/140038/2/term2206_am.pd

    Translation of immunomodulatory therapy to treat chronic heart failure: Preclinical studies to first in human

    Get PDF
    BACKGROUND: Inflammation has been associated with progression and complications of chronic heart failure (HF) but no effective therapy has yet been identified to treat this dysregulated immunologic state. The selective cytopheretic device (SCD) provides extracorporeal autologous cell processing to lessen the burden of inflammatory activity of circulating leukocytes of the innate immunologic system. AIM: The objective of this study was to evaluate the effects of the SCD as an extracorporeal immunomodulatory device on the immune dysregulated state of HF. HF. METHODS AND RESULTS: SCD treatment in a canine model of systolic HF or HF with reduced ejection fraction (HFrEF) diminished leukocyte inflammatory activity and enhanced cardiac performance as measured by left ventricular (LV) ejection fraction and stroke volume (SV) up to 4 weeks after treatment initiation. Translation of these observations in first in human, proof of concept clinical study was evaluated in a patient with severe HFrEFHFrEF ineligible for cardiac transplantation or LV LV assist device (LVAD) due to renal insufficiency and right ventricular dysfunction. Six hour SCD treatments over 6 consecutive days resulted in selective removal of inflammatory neutrophils and monocytes and reduction in key plasma cytokines, including tumor necrosis factor-alpha (TNF-α),), interleukin (IL)-6, IL-8, and monocyte chemoattractant protein (MCP)-1. These immunologic changes were associated with significant improvements in cardiac power output, right ventricular stroke work index, cardiac index and LVSV index…. Stabilization of renal function with progressive volume removal permitted successful LVAD implantation. CONCLUSION: This translational research study demonstrates a promising immunomodulatory approach to improve cardiac performance in HFrEFHFrEF and supports the important role of inflammation in the progression of HFHF

    A Biomimetic Membrane Device That Modulates the Excessive Inflammatory Response to Sepsis

    Get PDF
    OBJECTIVE: Septic shock has a clinical mortality rate approaching fifty percent. The major clinical manifestations of sepsis are due to the dysregulation of the host's response to infection rather than the direct consequences of the invading pathogen. Central to this initial immunologic response is the activation of leukocytes and microvascular endothelium resulting in cardiovascular instability, lung injury and renal dysfunction. Due to the primary role of leukocyte activation in the sepsis syndrome, a synthetic biomimetic membrane, called a selective cytopheretic device (SCD), was developed to bind activated leukocytes. The incorporation of the SCD along an extracorporeal blood circuit coupled with regional anticoagulation with citrate to lower blood ionized calcium was devised to modulate leukocyte activation in sepsis. DESIGN: Laboratory investigation. SETTING: University of Michigan Medical School. SUBJECTS: Pigs weighing 30-35 kg. INTERVENTIONS: To assess the effect of the SCD in septic shock, pigs were administered 30×10(10) bacteria/kg body weight of Escherichia coli into the peritoneal cavity and within 1 hr were immediately placed in an extracorporeal circuit containing SCD. MEASUREMENTS AND MAIN RESULTS: In this animal model, the SCD with citrate compared to control groups without the SCD or with heparin anticoagulation ameliorated the cardiovascular instability and lung sequestration of activated leukocytes, reduced renal dysfunction and improved survival time compared to various control groups. This effect was associated with minimal elevations of systemic circulating neutrophil activation. CONCLUSIONS: These preclinical studies along with two favorable exploratory clinical trials form the basis of an FDA-approved investigational device exemption for a pivotal multicenter, randomized control trial currently underway

    Aerodynamic vectoring particle sorting

    No full text
    An experimental and numerical demonstration of a new, non-contact particle sorting technique called Aerodynamic Vectoring Particle Sorting (AVPS) is presented. AVPS uses secondary blowing and suction control flows to sharply turn a 2D, particle-laden jet. As the jet is turned, particles present in the flow experience a resultant force, dependent upon their size and due to the combined effects of pressure, inertia, and drag. Since the balance of these forces determines the particle\u27s trajectory, turning the flow leads to a separation of particles downstream. This simple, low-pressure-drop sorting technique classifies particles with less risk of damage or contamination than currently available sorting devices. AVPS is experimentally demonstrated using a rectangular air jet. Particle size and trajectory are measured using the Shadowgraphy method. Numerical simulations are performed using the commercial CFD solver FLUENT to calculate the 2D turbulent vectored jet flow field using a RANS approach. Examination of the mean and the standard deviation of measured and computed particle trajectories is used to determine the range of particle sizes that can be effectively sorted using AVPS

    Particle sorting by aerodynamic vectoring

    No full text
    An experimental and numerical demonstration of a new, non-contact particle sorting technique called Aerodynamic Vectoring Particle Sorting (AVPS) is presented. AVPS uses secondary blowing and suction control flows to sharply turn a 2D, particle-laden jet. As the jet is turned, particles present in the flow experience a resultant force, dependent upon their size and due to the combined effects of pressure, inertia, and drag. Since the balance of these forces determines the particle\u27s trajectory, turning the flow leads to a separation of particles downstream. This simple, low-pressure-drop sorting technique classifies particles with less risk of damage or contamination than currently available sorting devices. AVPS is experimentally demonstrated using a rectangular air jet. Particle size and trajectory are measured using the Shadowgraphy method. Numerical simulations are performed using the commercial CFD solver FLUENT to calculate the 2D turbulent vectored jet flow field using a RANS approach. Examination of the mean and the standard deviation of measured and computed particle trajectories is used to determine the range of particle sizes that can be effectively sorted using AVPS

    Classification of Particles by size using aerodynamic vectoring

    No full text

    Immunomodulatory Device Promotes a Shift of Circulating Monocytes to a Less Inflammatory Phenotype in Chronic Hemodialysis Patients

    No full text
    Patients with end-stage renal disease (ESRD) on chronic hemodialysis (HD) suffer accelerated morbidity and mortality rates caused by cardiovascular disease and infections. Chronic inflammation plays a critical role in these poor outcomes. The activated monocyte (MO) has become a prime therapeutic target to modulate this inflammatory process. A selective cytopheretic device (SCD) was evaluated to assess its effects on the circulating MO pool. A pilot trial was undertaken in 15 ESRD patients on HD with C-reactive protein (CRP) levels greater than 5 mg/dl. An excellent safety profile was observed with no decline in leukocyte (LE) or platelet counts. The effect of SCD therapy on MO phenotypes in these patients was determined on peripheral blood MO utilizing flow cytometry. SCD therapy promoted a shift in MO phenotype from predominantly CD14 expressing MO at baseline/pre-SCD therapy to CD14 expressing MO post-SCD therapy. A significant shift in MO population phenotype afforded by a single SCD therapy session was observed (p \u3c 0.013). In a subset of patients (n = 7) presenting with type 2 diabetes mellitus (T2D), this persistent decline in MO CD14 expression was sustained as long as 2 weeks posttherapy. These results demonstrate that the SCD therapy has the potential to modulate the chronic proinflammatory state in ESRD patients

    An Immunomodulatory Device Improves Insulin Resistance in Obese Porcine Model of Metabolic Syndrome

    No full text
    Obesity is associated with tissue inflammation which is a crucial etiology of insulin resistance. This inflammation centers around circulating monocytes which form proinflammatory adipose tissue macrophages (ATM). Specific approaches targeting monocytes/ATM may improve insulin resistance without the adverse side effects of generalized immunosuppression. In this regard, a biomimetic membrane leukocyte processing device, called the selective cytopheretic device (SCD), was evaluated in an Ossabaw miniature swine model of insulin resistance with metabolic syndrome. Treatment with the SCD in this porcine model demonstrated a decline in circulating neutrophil activation parameters and monocyte counts. These changes were associated with improvements in insulin resistance as determined with intravenous glucose tolerance testing. These improvements were also reflected in lowering of homeostatic model assessment- (HOMA-) insulin resistant (IR) scores for up to 2 weeks after SCD therapy. These results allow for the planning of first-in-man studies in obese type 2 diabetic patients

    An Immunomodulatory Device Improves Insulin Resistance in Obese Porcine Model of Metabolic Syndrome

    No full text
    Obesity is associated with tissue inflammation which is a crucial etiology of insulin resistance. This inflammation centers around circulating monocytes which form proinflammatory adipose tissue macrophages (ATM). Specific approaches targeting monocytes/ATM may improve insulin resistance without the adverse side effects of generalized immunosuppression. In this regard, a biomimetic membrane leukocyte processing device, called the selective cytopheretic device (SCD), was evaluated in an Ossabaw miniature swine model of insulin resistance with metabolic syndrome. Treatment with the SCD in this porcine model demonstrated a decline in circulating neutrophil activation parameters and monocyte counts. These changes were associated with improvements in insulin resistance as determined with intravenous glucose tolerance testing. These improvements were also reflected in lowering of homeostatic model assessment-(HOMA-) insulin resistant (IR) scores for up to 2 weeks after SCD therapy. These results allow for the planning of first-in-man studies in obese type 2 diabetic patients
    corecore