326 research outputs found

    The effect of prolonged simulated non- gravitational environment on mineral balance in the adult male, volume 1 Final report

    Get PDF
    Effect of prolonged bed rest with simulated weightlessness on mineral balance in male adult - Vol.

    The Atmospheric Infrared Sounder Version 6 Cloud Products

    Get PDF
    The version 6 cloud products of the Atmospheric Infrared Sounder (AIRS) and Advanced Microwave Sounding Unit (AMSU) instrument suite are described. The cloud top temperature, pressure, and height and effective cloud fraction are now reported at the AIRS field-of-view (FOV) resolution. Significant improvements in cloud height assignment over version 5 are shown with FOV-scale comparisons to cloud vertical structure observed by the CloudSat 94 GHz radar and the Cloud-Aerosol LIdar with Orthogonal Polarization (CALIOP). Cloud thermodynamic phase (ice, liquid, and unknown phase), ice cloud effective diameter D(sub e), and ice cloud optical thickness () are derived using an optimal estimation methodology for AIRS FOVs, and global distributions for 2007 are presented. The largest values of tau are found in the storm tracks and near convection in the tropics, while D(sub e) is largest on the equatorial side of the midlatitude storm tracks in both hemispheres, and lowest in tropical thin cirrus and the winter polar atmosphere. Over the Maritime Continent the diurnal variability of tau is significantly larger than for the total cloud fraction, ice cloud frequency, and D(sub e), and is anchored to the island archipelago morphology. Important differences are described between northern and southern hemispheric midlatitude cyclones using storm center composites. The infrared-based cloud retrievals of AIRS provide unique, decadal-scale and global observations of clouds over portions of the diurnal and annual cycles, and capture variability within the mesoscale and synoptic scales at all latitudes

    High spatial resolution imaging of methane and other trace gases with the airborne Hyperspectral Thermal Emission Spectrometer (HyTES)

    Get PDF
    Currently large uncertainties exist associated with the attribution and quantification of fugitive emissions of criteria pollutants and greenhouse gases such as methane across large regions and key economic sectors. In this study, data from the airborne Hyperspectral Thermal Emission Spectrometer (HyTES) have been used to develop robust and reliable techniques for the detection and wide-area mapping of emission plumes of methane and other atmospheric trace gas species over challenging and diverse environmental conditions with high spatial resolution that permits direct attribution to sources. HyTES is a pushbroom imaging spectrometer with high spectral resolution (256 bands from 7.5 to 12 µm), wide swath (1–2 km), and high spatial resolution (∼ 2 m at 1 km altitude) that incorporates new thermal infrared (TIR) remote sensing technologies. In this study we introduce a hybrid clutter matched filter (CMF) and plume dilation algorithm applied to HyTES observations to efficiently detect and characterize the spatial structures of individual plumes of CH4, H2S, NH3, NO2, and SO2 emitters. The sensitivity and field of regard of HyTES allows rapid and frequent airborne surveys of large areas including facilities not readily accessible from the surface. The HyTES CMF algorithm produces plume intensity images of methane and other gases from strong emission sources. The combination of high spatial resolution and multi-species imaging capability provides source attribution in complex environments. The CMF-based detection of strong emission sources over large areas is a fast and powerful tool needed to focus on more computationally intensive retrieval algorithms to quantify emissions with error estimates, and is useful for expediting mitigation efforts and addressing critical science questions

    Morphological Characters of the Thickbody Skate Amblyraja frerichsi (Krefft 1968) (Rajiformes: Rajidae), with Notes on Its Biology

    Get PDF
    Detailed descriptions of morphological features, morphometrics, neurocranium anatomy, clasper structure and egg case descriptions are provided for the thickbody skate Amblyraja frerichsi; a rare, deep-water species from Chile, Argentina and Falkland Islands. The species diagnosis is complemented from new observations and aspects such as colour, size and distribution are described. Geographic and bathymetric distributional ranges are discussed as relevant features of this taxońs biology. Additionally, the conservation status is assessed including bycatch records from Chilean fisheries

    Identifying patient preferences for communicating risk estimates: A descriptive pilot study

    Get PDF
    BACKGROUND: Patients increasingly seek more active involvement in health care decisions, but little is known about how to communicate complex risk information to patients. The objective of this study was to elicit patient preferences for the presentation and framing of complex risk information. METHOD: To accomplish this, eight focus group discussions and 15 one-on-one interviews were conducted, where women were presented with risk data in a variety of different graphical formats, metrics, and time horizons. Risk data were based on a hypothetical woman's risk for coronary heart disease, hip fracture, and breast cancer, with and without hormone replacement therapy. Participants' preferences were assessed using likert scales, ranking, and abstractions of focus group discussions. RESULTS: Forty peri- and postmenopausal women were recruited through hospital fliers (n = 25) and a community health fair (n = 15). Mean age was 51 years, 50% were non-Caucasian, and all had completed high school. Bar graphs were preferred by 83% of participants over line graphs, thermometer graphs, 100 representative faces, and survival curves. Lifetime risk estimates were preferred over 10 or 20-year horizons, and absolute risks were preferred over relative risks and number needed to treat. CONCLUSION: Although there are many different formats for presenting and framing risk information, simple bar charts depicting absolute lifetime risk were rated and ranked highest overall for patient preferences for format

    Noninvasive assessment of asthma severity using pulse oximeter plethysmograph estimate of pulsus paradoxus physiology

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pulsus paradoxus estimated by dynamic change in area under the oximeter plethysmograph waveform (PEP) might provide a measure of acute asthma severity. Our primary objective was to determine how well PEP correlates with forced expiratory volume in 1-second (%FEV<sub>1</sub>) (criterion validity) and change of %FEV<sub>1 </sub>(responsiveness) during treatment in pediatric patients with acute asthma exacerbations.</p> <p>Methods</p> <p>We prospectively studied subjects 5 to 17 years of age with asthma exacerbations. PEP, %FEV<sub>1</sub>, airway resistance and accessory muscle use were recorded at baseline and at 2 and 4 hours after initiation of corticosteroid and bronchodilator treatments. Statistical associations were tested with Pearson or Spearman rank correlations, logistic regression using generalized estimating equations, or Wilcoxon rank sum tests.</p> <p>Results</p> <p>We studied 219 subjects (median age 9 years; male 62%; African-American 56%). Correlation of PEP with %FEV<sub>1 </sub>demonstrated criterion validity (r = - 0.44, 95% confidence interval [CI], - 0.56 to - 0.30) and responsiveness at 2 hours (r = - 0.31, 95% CI, - 0.50 to - 0.09) and 4 hours (r = - 0.38, 95% CI, - 0.62 to - 0.07). PEP also correlated with airway resistance at baseline (r = 0.28 for ages 5 to 10; r = 0.45 for ages 10 to 17), but not with change over time. PEP was associated with accessory muscle use (OR 1.16, 95% CI, 1.11 to 1.21, P < 0.0001).</p> <p>Conclusions</p> <p>PEP demonstrates criterion validity and responsiveness in correlations with %FEV<sub>1</sub>. PEP correlates with airway resistance at baseline and is associated with accessory muscle use at baseline and at 2 and 4 hours after initiation of treatment. Incorporation of this technology into contemporary pulse oximeters may provide clinicians improved parameters with which to make clinical assessments of asthma severity and response to treatment, particularly in patients who cannot perform spirometry because of young age or severity of illness. It might also allow for earlier recognition and improved management of other disorders leading to elevated pulsus paradoxus.</p

    Parenteral oestrogen in the treatment of prostate cancer: a systematic review

    Get PDF
    The objectives of this study were to assess the effectiveness and safety of parenteral oestrogen in the treatment of prostate cancer, and to examine any dose relationship. A systematic review was undertaken. Electronic databases, published paper and internet resources were searched to locate published and unpublished studies with no restriction by language or publication date. Studies included were randomised controlled trials of parenteral oestrogen in patients with prostate cancer; other study designs were also included to examine dose–response. Study selection, appraisal, data extraction and quality assessment were performed by one reviewer and independently checked by another. Twenty trials were included in the review. The trials differed with regard to the included patients, formulation and dose of parenteral oestrogen, comparator used, outcome measures reported and the duration of follow-up. The results provide no evidence to suggest that parenteral oestrogen, in doses sufficient to produce castrate levels of testosterone, is less effective than luteinising hormone-releasing hormone (LHRH) or orchidectomy in controlling prostate cancer, or that it is consistently associated with an increase in cardiovascular mortality. Further well-conducted trials of parenteral oestrogen are required. A pilot randomised controlled trial comparing transdermal oestrogen to LHRH analogues in men with locally advanced or metastatic prostate cancer is underway in the United Kingdom

    A critical appraisal of appendage disparity and homology in fishes

    Full text link
    Fishes are both extremely diverse and morphologically disparate. Part of this disparity can be observed in the numerous possible fin configurations that may differ in terms of the number of fins as well as fin shapes, sizes and relative positions on the body. Here, we thoroughly review the major patterns of disparity in fin configurations for each major group of fishes and discuss how median and paired fin homologies have been interpreted over time. When taking into account the entire span of fish diversity, including both extant and fossil taxa, the disparity in fin morphologies greatly complicates inferring homologies for individual fins. Given the phylogenetic scope of this review, structural and topological criteria appear to be the most useful indicators of fin identity. We further suggest that it may be advantageous to consider some of these fin homologies as nested within the larger framework of homologous fin‐forming morphogenetic fields. We also discuss scenarios of appendage evolution and suggest that modularity may have played a key role in appendage disparification. Fin modules re‐expressed within the boundaries of fin‐forming fields could explain how some fins may have evolved numerous times independently in separate lineages (e.g., adipose fin), or how new fins may have evolved over time (e.g., anterior and posterior dorsal fins, pectoral and pelvic fins). We favour an evolutionary scenario whereby median appendages appeared from a unique field of competence first positioned throughout the dorsal and ventral midlines, which was then redeployed laterally leading to paired appendages.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/151971/1/faf12402_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/151971/2/faf12402.pd

    Hearing aid effectiveness after aural rehabilitation - individual versus group (HEARING) trial: RCT design and baseline characteristics

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hearing impairment is the most common body system disability in veterans. In 2008, nearly 520,000 veterans had a disability for hearing loss through the Department of Veterans Affairs (VA). Changes in eligibility for hearing aid services, along with the aging population, contributed to a greater than 300% increase in the number of hearing aids dispensed from 1996 to 2006. In 2006, the VA committed to having no wait times for patient visits while providing quality clinically-appropriate care. One approach to achieving this goal is the use of group visits as an alternative to individual visits. We sought to determine: 1) if group hearing aid fitting and follow-up visits were at least as effective as individual visits, and 2) whether group visits lead to cost savings through the six month period after the hearing aid fitting. We describe the rationale, design, and characteristics of the baseline cohort of the first randomized clinical trial to study the impact of group versus individual hearing aid fitting and follow-up visits.</p> <p>Methods</p> <p>Participants were recruited from the VA Puget Sound Health Care System Audiology Clinic. Eligible patients had no previous hearing aid use and monaural or binaural air-conduction hearing aids were ordered at the evaluation visit. Participants were randomized to receive the hearing aid fitting and the hearing aid follow-up in an individual or group visit. The primary outcomes were hearing-related function, measured with the first module of the Effectiveness of Aural Rehabilitation (Inner EAR), and hearing aid adherence. We tracked the total cost of planned and unplanned audiology visits over the 6-month interval after the hearing aid fitting.</p> <p>Discussion</p> <p>A cohort of 659 participants was randomized to receive group or individual hearing aid fitting and follow-up visits. Baseline demographic and self-reported health status and hearing-related measures were evenly distributed across the treatment arms.</p> <p>Outcomes after the 6-month follow-up period are needed to determine if group visits were as least as good as those for individual visits and will be reported in subsequent publication.</p> <p>Trial Registration</p> <p>NCT00260663</p
    corecore