    Progress in large field-of-view interventional planar scintigraphy and SPECT imaging

    Get PDF
    INTRODUCTION: Handheld gamma cameras and gamma probes have been successfully implemented for enabling nuclear image or radio-guidance in minimally-invasive procedures. There is an opportunity for large field-of-view interventional planar scintigraphy and SPECT imaging to complement these small field-of-view devices for two reasons. First, a large field-of-view camera enables imaging of relatively larger organs and activity accumulations that are not close to the patient's skin. And second, more precise corrections can be implemented in the SPECT reconstruction algorithm, improving its quality. AREAS COVERED: This review article discusses the progress that has been made in the field of large field-of-view interventional planar scintigraphy and SPECT imaging. First, an overview of planar scintigraphy and SPECT is provided. Second, an exploration is given of the potential applications where large field-of-view interventional planar scintigraphy and SPECT imaging may be employed. And third, the requirements for scanner hardware are discussed and an overview of the possible system configurations is provided. EXPERT OPINION: We believe that there is an opportunity for large field-of-view interventional planar scintigraphy and SPECT imaging to assist clinical workflows. A major effort is now required to evaluate the prototype systems in clinical studies so that valuable practical experience can be obtained

    Adaptive scan duration in SPECT: Evaluation for radioembolization

    Get PDF
    Purpose: It may be challenging to select the optimal scan duration for single-photon emission computed tomography (SPECT) protocols because the activity distribution characteristics can differ in every scan. Using simulations and experiments, we investigated whether the scan duration can be optimized for every scan separately by evaluating the activity distribution during scanning. We refer to this as adaptive scanning. Methods: The feasibility of adaptive scanning was evaluated for the detection of extrahepatic depositions in the pretreatment procedure of radioembolization, in which 99mTc-labeled macroaggregated albumin ( 99mTc-MAA) is injected into the liver. We simulated fast 1-min detector rotations and updated the reconstruction with the newly collected counts after every rotation. The scan was terminated when one of the two criteria was met: (a) when the mask difference of the detected extrahepatic deposition between two consecutive rotations was lower than 5%; or (b) when the reconstructed extrahepatic activity was negligible with respect to the total reconstructed activity (<0.075%). The performance of adaptive scanning was evaluated using a digital phantom with various activity distributions, a physical phantom experiment, and simulations based on 129 patient activity distributions. Results: The digital phantom data showed that the scan termination times substantially depended on the activity distribution characteristics. The experimental phantom data showed the feasibility of adaptive scanning with physical scanner measurements and illustrated that fast detector motion was not limiting the adaptive scanning performance. The patient data showed a large spread in the scan terminations times. By adaptive scanning, the mean scan duration of the patient distributions was shortened from 20 min (current clinical protocol) to 4.8 ± 0.2 min. The detection accuracy of extrahepatic depositions was unaffected and the mean difference in the extrahepatic deposition masks (compared with the 20-min scan) was only 7.0 ± 1.0%. Conclusion: Our study suggests that the SPECT scan duration can be personalized by assessing the activity distribution characteristics during scanning for the detection of extrahepatic depositions in the pretreatment procedure of radioembolization. The adaptive scanning approach might also be of benefit for other SPECT protocols, as long as a measure of interest is available for optimization

    Monte Carlo-based scatter correction for the SMARTZOOM collimator

    Get PDF
    BACKGROUND: Myocardial perfusion imaging is a commonly performed SPECT protocol and hence it would be beneficial if its scan duration could be shortened. For traditional gamma cameras, two developments have separately shown to allow for a shortened scan duration: (i) reconstructing with Monte Carlo-based scatter correction instead of dual-energy window scatter correction and (ii) acquiring projections with the SMARTZOOM collimator instead of a parallel-hole collimator. This study investigates which reduction in scan duration can be achieved when both methods are combined in a single system. RESULTS: The SMARTZOOM collimator was implemented in a Monte Carlo-based reconstruction package and the implementation was validated through image quality phantom experiments. The potential for scan duration reduction was evaluated with a phantom configuration that is realistic for myocardial perfusion imaging. The original reconstruction quality was achieved in 76 ± 8% of the original scan duration when switching from dual-energy window scatter correction to Monte Carlo-based scatter correction. The original reconstruction quality was achieved in 56 ± 13% of the original scan duration when switching from the parallel-hole to the SMARTZOOM collimator. After combining both methods in a single system, the original reconstruction quality was achieved in 34 ± 7% of the original scan duration. CONCLUSIONS: Monte Carlo-based scatter correction combined with the SMARTZOOM collimator can further decrease the scan duration in myocardial perfusion imaging

    Intraprocedural C-arm dual-phase cone-beam enhancement patterns correlate with tumor absorbed dose after radioembolization

    Get PDF
    BACKGROUND: Recent studies have shown a clear relationship between absorbed dose and tumor response to treatment after hepatic radioembolization. These findings help to create more personalized treatment planning and dosimetry. However, crucial to this goal is the ability to predict the dose distribution prior to treatment. The microsphere distribution is ultimately determined by (i) the hepatic vasculature and the resulting blood flow dynamics and (ii) the catheter position. PURPOSE: To show that pretreatment, intra-procedural imaging of blood flow patterns, as quantified by catheter-directed intra-arterial contrast enhancement, correlate with posttreatment microsphere accumulation and, consequently, absorbed dose. MATERIALS AND METHODS: Patients who participated in a clinical trial (NCT01177007) and for whom both a pretreatment dual-phase contrast-enhanced cone-beam CT (CBCT) and a posttreatment 90Y PET/CT scan were available were included in this retrospective study. Tumors and perfused volumes were manually delineated on the CBCT by an experienced radiologist. The mean, sum, and standard deviation of the voxels in each volume were recorded. The delineations were transferred to the PET-based absorbed dose maps by coregistration of the corresponding CTs. Linear multiple regression was used to correlate pretreatment CBCT enhancement to posttreatment 90Y PET/CT-based absorbed dose in each region. Leave-one-out cross-validation and Bland-Altman analyses were performed on the predicted versus measured absorbed doses. RESULTS: Nine patients, with a total of 23 tumors were included. All presented with hepatocellular carcinoma (HCC). Visually, all patients had a clear correspondence between CBCT enhancement and absorbed dose. The correlation between CBCT enhancement and posttherapy absorbed tumor dose based was strong (R2 = 0.91), and moderate for the non-tumor liver tissue (R2 = 0.61). Limits of agreement were approximately ±55 Gray for tumor tissue. CONCLUSION: There is a linear relationship between pretreatment blood dynamics in HCC tumors and posttreatment absorbed dose, which, if shown to be generalizable, allows for pretreatment tumor absorbed dose prediction

    Fast technetium-99m liver SPECT for evaluation of the pretreatment procedure for radioembolization dosimetry

    Get PDF
    Purpose: The efficiency of radioembolization procedures could be greatly enhanced if results of the 99m Tc-MAA pretreatment procedure were immediately available in the interventional suite, enabling 1-day procedures as a result of direct estimation of the hepatic radiation dose and lung shunt fraction. This would, however, require a relatively fast, but still quantitative, SPECT procedure, which might be achieved with acquisition protocols using nonuniform durations of the projection images. Methods: SPECT liver images of the 150-MBq 99m Tc-MAA pretreatment procedure were simulated for eight different lesion locations and two different lesion sizes using the digital XCAT phantom for both single- and dual-head scanning geometries with respective total acquisition times of 1, 2, 5, 10, and 30 min. Three nonuniform projection-time acquisition protocols (“half-circle SPECT (HCS),” “nonuniform SPECT (NUS) I,” and “NUS II”) for fast quantitative SPECT of the liver were designed and compared with the standard uniform projection-time protocol. Images were evaluated in terms of contrast-to-noise ratio (CNR), activity recovery coefficient (ARC), tumor/non-tumor (T/N) activity concentration ratio, and lung shunt fraction (LSF) estimation. In addition, image quality was verified with a physical phantom experiment, reconstructed with both clinical and Monte Carlo-based reconstruction software. Results: Simulations showed no substantial change in image quality and dosimetry by usage of a nonuniform projection-time acquisition protocol. Upon shortening acquisition times, CNR dropped, but ARC, T/N ratio, and LSF estimates were stable across all simulated acquisition times. Results of the physical phantom were in agreement with those of the simulations. Conclusion: Both uniform and nonuniform projection-time acquisition liver SPECT protocols yield accurate dosimetric metrics for radioembolization treatment planning in the interventional suite within 10 min, without compromising image quality. Consequently, fast quantitative SPECT of the liver in the interventional suite is feasible

    Interventional respiratory motion compensation by simultaneous fluoroscopic and nuclear imaging: a phantom study

    Get PDF
    Purpose A compact and mobile hybrid c-arm scanner, capable of simultaneously acquiring nuclear and fluoroscopic projections and SPECT/CBCT, was developed to aid fluoroscopy-guided interventional procedures involving the administration of radionuclides (e.g. hepatic radioembolization). However, as in conventional SPECT/CT, the acquired nuclear images may be deteriorated by patient respiratory motion. We propose to perform compensation for respiratory motion by extracting the motion signal from fluoroscopic projections so that the nuclear counts can be gated into motion bins. The purpose of this study is to quantify the performance of this motion compensation technique with phantom experiments. Methods Anthropomorphic phantom configurations that are representative of distributions obtained during the pre-treatment procedure of hepatic radioembolization were placed on a stage that translated with three different motion patterns. Fluoroscopic projections and nuclear counts were simultaneously acquired under planar and SPECT/CBCT imaging. The planar projections were visually assessed. The SPECT reconstructions were visually assessed and quantitatively assessed by calculating the activity recovery of the spherical inserts in the phantom. Results The planar nuclear projections of the translating anthropomorphic phantom were blurry when no motion compensation was applied. With motion compensation, the nuclear projections became representative of the stationary phantom nuclear projection. Similar behavior was observed for the visual quality of SPECT reconstructions. The mean error of the activity recovery in the uncompensated SPECT reconstructions was 15.8±0.9% for stable motion, 11.9±0.9% for small variations, and 11.0±0.9% for large variations. When applying motion compensation, the mean error decreased to 1.8±1.6% for stable motion, 2.2±1.5% for small variations, and 5.2±2.5% for large variations. Conclusion A compact and mobile hybrid c-arm scanner, capable of simultaneously acquiring nuclear and fluoroscopic projections, can perform compensation for respiratory motion. Such motion compensation results in sharper planar nuclear projections and increases the quantitative accuracy of the SPECT reconstructions

    Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT/CT systems

    Get PDF
    Background: Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. Methods: Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 – 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. Re

    Comparison of the Biograph Vision and Biograph mCT for quantitative Y-90 PET/CT imaging for radioembolisation

    Get PDF
    BACKGROUND: New digital PET scanners with improved time of flight timing and extended axial field of view such as the Siemens Biograph Vision have come on the market and are expected to replace current generation photomultiplier tube (PMT)-based systems such as the Siemens Biograph mCT. These replacements warrant a direct comparison between the systems, so that a smooth transition in clinical practice and research is guaranteed, especially when quantitative values are used for dosimetry-based treatment guidance. The new generation digital PET scanners offer increased sensitivity. This could particularly benefit 90Y imaging, which tends to be very noisy owing to the small positron branching ratio and high random fraction of 90Y. This study aims to determine the ideal reconstruction settings for the digital Vision for quantitative 90Y imaging and to evaluate the image quality and quantification of the digital Vision in comparison with its predecessor, the PMT-based mCT, for 90Y imaging in radioembolisation procedures. METHODS: The NEMA image quality phantom was scanned to determine the ideal reconstruction settings for the Vision. In addition, an anthropomorphic phantom was scanned with both the Vision and the mCT, mimicking a radioembolisation patient with lung, liver, tumour, and extrahepatic deposition inserts. Image quantification of the anthropomorphic phantom was assessed by the lung shunt fraction, the tumour to non-tumour ratio, the parenchymal dose, and the contrast to noise ratio of extrahepatic depositions. RESULTS: For the Vision, a reconstruction with 3 iterations, 5 subsets, and no post-reconstruction filter is recommended for quantitative 90Y imaging, based on the convergence of the recovery coefficient. Comparing both systems showed that the noise level of the Vision is significantly lower than that of the mCT (background variability of 14% for the Vision and 25% for the mCT at 2.5·103 MBq for the 37 mm sphere size). For quantitative 90Y measures, such as needed in radioembolisation, both systems perform similarly. CONCLUSIONS: We recommend to reconstruct 90Y images acquired on the Vision with 3 iterations, 5 subsets, and no post-reconstruction filter for quantitative imaging. The Vision provides a reduced noise level, but similar quantitative accuracy as compared with its predecessor the mCT

    Computed tomography-based calcium scoring in cadaver leg arteries: Influence of dose, reader, and reconstruction algorithm

    Get PDF
    PURPOSE: Computed tomography (CT) might be a good diagnostic test to accurately quantify calcium in vascular beds but there are multiple factors influencing the quantification. The aim of this study was to investigate the influence of different computed tomography protocol settings in the quantification of calcium in the lower extremities using modified Agatston and volume scores. METHODS: Fresh-frozen human legs were scanned at different tube current protocols and reconstructed at different slice thickness. Two different iterative reconstruction protocols for conventional CT images were compared. Calcium was manually scored using modified Agatston and volume scores. Outcomes were statistically analyzed using Wilcoxon signed-rank tests and mean absolute and relative differences were plotted in Bland-Altman plots. RESULTS: Of the 20 legs, 16 had CT detectable calcifications. Differences between thick and thin slice reconstruction protocols were 129 Agatston units and 125% for Agatston and 78.4 mm3 and 57.8% for volume (all p ≤ 0.001). No significant differences were found between low and high tube current protocols. Differences between iDose4 and IMR reconstruction protocols for modified Agatston were 34.2 Agatston units and 17.7% and the volume score 33.5 mm3 and 21.2% (all p ≤ 0.001). CONCLUSIONS: Slice thickness reconstruction and reconstruction method protocols influenced the modified Agatston and volume scores in leg arteries, but tube current and different observers did not have an effect. This data emphasizes the need for standardized quantification of leg artery calcifications. Possible implications are in the development of a more universal quantification method, independent of the type of scan and vasculature

    Association of Ischemic Core Imaging Biomarkers With Post-Thrombectomy Clinical Outcomes in the MR CLEAN Registry

    Get PDF
    Background: A considerable proportion of acute ischemic stroke patients treated with endovascular thrombectomy (EVT) are dead or severely disabled at 3 months despite successful reperfusion. Ischemic core imaging biomarkers may help to identify patients who are more likely to have a poor outcome after endovascular thrombectomy (EVT) despite successful reperfusion. We studied the association of CT perfusion-(CTP), CT angiography-(CTA), and non-contrast CT-(NCCT) based imaging markers with poor outcome in patients who underwent EVT in daily clinical practice. Methods: We included EVT-treated patients (July 2016–November 2017) with an anterior circulation occlusion from the Multicenter Randomized Clinical Trial of Endovascular Treatment for Acute Ischemic Stroke in the Netherlands (MR CLEAN) Registry with available baseline CTP, CTA, and NCCT. We used multivariable binary and ordinal logistic regression to analyze the association of CTP ischemic core volume, CTA-Collateral Score (CTA-CS), and Alberta Stroke Program Early CT Score (ASPECTS) with poor outcome (modified Rankin Scale score (mRS) 5-6) and likelihood of having a lower score on the mRS at 90 days. Results: In 201 patients, median core volume was 13 (IQR 5-41) mL. Median ASPECTS was 9 (IQR 8-10). Most patients had grade 2 (83/201; 42%) or grade 3 (28/201; 14%) collaterals. CTP ischemic core volume was associated with poor outcome [aOR per 10 mL 1.02 (95%CI 1.01–1.04)] and lower likelihood of having a lower score on the mRS at 90 days [aOR per 10 mL 0.85 (95% CI 0.78–0.93)]. In multivariable analysis, neither CTA-CS nor ASPECTS were significantly associated with poor outcome or the likelihood of having a lower mRS. Conclusion: In our population of patients treated with EVT in daily clinical practice, CTP ischemic core volume is associated with poor outcome and lower likelihood of shift toward better outcome in contrast to either CTA-CS or ASPECTS
    • …