50 research outputs found

    Performance Characteristics and Temperature Compensation Method of Fluid Property Sensor Based on Tuning-Fork Technology

    Get PDF
    Fluid property sensor (FPS) based on tuning-fork technology is applied to the measurement of the contaminant level of lubricant oil. The measuring principle of FPS sensor is derived and proved together with its resolution. The performance characteristics of the FPS sensor, such as sensitivity coefficient, resolution, and quality factor, are analyzed. A temperature compensation method is proposed to eliminate the temperature-dependence of the measuring parameters, and its validity is investigated by numerical simulation of sensitivity, oscillating frequency, and dielectric constant. The values of purification efficiency obtained using microwave and without microwave are compared experimentally

    Engineering hibiscus-like riboflavin/ZIF-8 microsphere composites to enhance transepithelial corneal cross-linking

    Get PDF
    Riboflavin-5-phosphate (RF) is the most commonly used photosensitizer in corneal cross-linking (CXL), but its hydrophilicity and negative charge limit its penetration through the corneal epithelium into the stroma. To enhance the corneal permeability of RF and promote its efficacy in the treatment of keratoconus, novel hibiscus-like RF@ZIF-8 microsphere composites [6RF@ZIF-8 NF (nanoflake)] are prepared using ZIF-8 nanomaterials as carriers, which are characterized by their hydrophobicity, positive potential, biocompatibility, high loading capacities, and large surface areas. Both hematoxylin and eosin endothelial staining and TUNEL assays demonstrate excellent biocompatibility of 6RF@ZIF-8 NF. In in vivo studies, the 6RF@ZIF-8 NF displayed excellent corneal permeation, and outstanding transepithelial CXL (TE-CXL) efficacy, slightly better than the conventional CXL protocol. Furthermore, the special hibiscus-like structures of 6RF@ZIF-8 NF meant that it has better TE-CXL efficacy than that of 6RF@ZIF-8 NP (nanoparticles) due to the larger contact area with the epithelium and the shorter RF release passage. These results suggest that the 6RF@ZIF-8 NF are promising for transepithelial corneal cross-linking, avoiding the need for epithelial debridement

    Overexpression of a Novel LcKNOX Transcription Factor from Liriodendron chinense Induces Lobed Leaves in Arabidopsis thaliana

    No full text
    Liriodendron chinense is a common ornamental tree that has attractive leaves, which is a valuable trait for use in landscape architecture. In this work, we aimed to identify the potential genes that control and regulate the development of L. chinense leaf lobes. Based on the transcriptome data for the leaf developmental stages we previously generated, two candidate genes were identified in this study. KNOTTED-LIKE HOMEOBOX(KNOX), encoding homeobox family proteins, play a large role in leaf lobe and leaf complexity regulation. Here, two full length KNOX genes from L. chinense were amplified and named LcKNOX1 and LcKNOX6 according to their sequence similarities with the respective Arabidopsis thaliana KNOX family genes. Overexpression vectors were constructed and subsequently transformed into wild type (WT) A. thaliana. Additionally, LcKNOX6 was expressed in tobacco leaves to examine its subcellular localization, and the 35S::LcKNOX6 transgenic A. thaliana leaf cells were imaged with the use of SEM. The expression of several genes that participate in KNOX gene regulation were validated by quantitative real-time PCR. The results show that LcKNOX1 produces almost the same phenotype as that found in WT A. thaliana. Notably, the LcKNOX6-1 lines presented deep leaf lobes that were similar to L. chinense leaf lobes. Two 35S::LcKNOX6 lines induced an abnormal growth phenotype whose seeds were abortive. In short, these results indicate that the LcKNOX6 gene might affect leaf development in A. thaliana and provide insights into the regulation of L. chinense leaf shaping

    Femtosecond Laser Irradiation of Carbon Nanotubes to Metal Electrodes

    No full text
    Carbon nanotubes (CNTs) have excellent performance, which means that they could be better electrical conductors. However, the problem of the connection of CNTs to electrodes limits their application. Particularly, improving connection efficiency while ensuring the quality of the connection is a big challenge, because it is difficult to form Ohmic contact between CNTs and electrodes. To address this issue, we propose the use of a femtosecond laser to irradiate the contact surface between the CNTs and the electrodes to obtain a good connection quality and electrical performance. At the same time, since the laser-induced connection acts on all the contact surfaces in the irradiation area, the connection efficiency can be improved, which provides a new idea for the large-scale preparation of the connection

    Validation of the RBP‐9801 oscillometric blood pressure monitor in the general population according to the association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard

    No full text
    Abstract The aim of this study was to evaluate the accuracy of the single upper‐arm cuff oscillometric blood pressure (BP) monitor RBP‐9801 developed for office and home BP measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060–2:2018). Subjects were recruited to fulfil the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. A total of 105 subjects were recruited and 85 were analyzed. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.3 ± 6.4/3.1 ± 5.8 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.24/5.03 mmHg (systolic/diastolic). The conclusion is that the RBP‐9801 oscillometric device for office and home BP measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060–2:2018) in the general population and can be recommended for clinic and self‐use at home

    Influencing factors associated with oral health among older hospitalized patients with ischemic stroke: A cross-sectional survey

    No full text
    Objective: To investigate the oral health status of older patients with ischemic stroke and analyze the influencing factors, providing valuable insights for developing effective oral health management strategies tailored for this population. Methods: A cross-sectional survey was conducted from January to June 2022, selecting 350 older patients with ischemic stroke from two tertiary hospitals in Chongqing. The Barthel Index (BI), Eating Assessment Tool (EAT-10), and Oral Health Assessment Tool (OHAT) were used to assess patients’ self-care ability, swallowing function, and oral health status, respectively. A self-designed questionnaire was used to collect demographic information, disease-related information, and oral health behaviors of the patients. Binary logistic regression analysis was performed to analyze related influencing factors. Results: A total of 346 older patients with ischemic stroke were included, with 199 males and 147 females. The median total score of OHAT was 5 (total score range 0–16). Dental decay (91.7%, 278/303) and poor oral hygiene (92.2%, 319/346) were the main oral health problems in this population. Binary logistic regression analysis showed that sex, hyperlipidemia, stroke severity, stroke events, oral health behaviors, and care dependency were influencing factors for the oral health of this population (P < 0.05). Conclusion: The study revealed that healthcare professionals should strengthen the oral health assessment of older patients with ischemic stroke and implement individualized health education and management measures based on the characteristics of high-risk groups to promote their oral health

    A capacitive mismatch calibration method for SAR ADCs based on TDC

    No full text
    Abstract The capacitance mismatch problem limits the accuracy improvement of high‐precision SAR ADCs (Successive Approximation Register Analog‐to‐Digital Converters). To address the capacitance array mismatch in SAR ADCs, this paper proposes a novel capacitor calibration scheme based on the Time‐to‐Digital Converter (TDC). This scheme achieves calibration accuracy as high as 0.01% and can be flexibly designed to meet the accuracy requirements of SAR ADCs. Simulation results indicate that the capacitance mismatch issue of a redundant capacitor 13‐bit SAR ADC can be completely eliminated, and the effective number of bits (ENOB) approach the ideal value of 13.18 bits. Additionally, the analog component of this scheme utilizes four inverter chains, two D flip‐flops, and four counters, without requiring a large area for auxiliary calibration capacitors
    corecore