177 research outputs found

    Accessibility Analysis of A-level Lin Pan Scenic Spot in Dayi County Based on Road Network

    Get PDF
    Chengdu vigorously promotes the construction and development of Lin Pan. Aiming at the distribution of A-level Lin Pan in Dayi County, this study analyzed the accessibility of A-level Lin Pan by using ArcGIS software, OD cost matrix analysis method and two-step mobile search method, and found that: (1) Accessibility of different A-class Lin Pan varies greatly, and the longest arrival time is almost twice that of the shortest. (2) The A-level Lin Pan scenic spot has A general economic driving effect on the local economy, and it is suggested to increase the construction of Lin Pan scenic spot according to the distribution of Lin Pan

    Style Matching or Content Matching? Moderating Role of Discrete Negative Emotions in the Effects of Managerial Responses Tailoring

    Get PDF
    Many firms are struggling with how to tailor their responses to online reviews expressing negative emotions. While most studies on the managerial response (MR) tailoring point to the importance of MR content, how the content is conveyed, often referred to as language style, has been underexplored. Drawing on the verbal mimicry and communication tailoring literature, we propose that style matching may be at least as important as content matching and play a different role when responding to reviews embedded with negative emotions. Further, we consider the differences among the various negative emotions expressed in reviews and explore how to tailor MR for reviews embedded with discrete negative emotions (anger, sadness, anxiety, and disgust) expressed in reviews. The results show that style matching is more effective for anger-embedded reviews and sadness-embedded reviews while content matching performs better for disgust-embedded reviews. However, these two tailoring strategies are not effective for anxiety-embedded reviews

    STGP: Spatio-temporal Gaussian process models for longitudinal neuroimaging data

    Get PDF
    Longitudinal neuroimaging data plays an important role in mapping the neural developmental profile of major neuropsychiatric and neurodegenerative disorders and normal brain. The development of such developmental maps is critical for the prevention, diagnosis, and treatment of many brain-related diseases. The aim of this paper is to develop a spatio-temporal Gaussian process (STGP) framework to accurately delineate the developmental trajectories of brain structure and function, while achieving better prediction by explicitly incorporating the spatial and temporal features of longitudinal neuroimaging data. Our STGP integrates a functional principal component model (FPCA) and a partition parametric space-time covariance model to capture the medium-to-large and small-to-medium spatio-temporal dependence structures, respectively. We develop a three-stage efficient estimation procedure as well as a predictive method based on a kriging technique. Two key novelties of STGP are that it can efficiently use a small number of parameters to capture complex non-stationary and non-separable spatio-temporal dependence structures and that it can accurately predict spatio-temporal changes. We illustrate STGP using simulated data sets and two real data analyses including longitudinal positron emission tomography data from the Alzheimers Disease Neuroimaging Initiative (ADNI) and longitudinal lateral ventricle surface data from a longitudinal study of early brain development

    Deriving detector-specific correction factors for rectangular small fields using a scintillator detector

    Get PDF
    The goal of this study was to investigate small field output factors (OFs) for flat-tening filter-free (FFF) beams on a dedicated stereotactic linear accelerator-based system. From this data, the collimator exchange effect was quantified, and detector-specific correction factors were generated. Output factors for 16 jaw-collimated small fields (from 0.5 to 2 cm) were measured using five different detectors including an ion chamber (CC01), a stereotactic field diode (SFD), a diode detector (Edge), Gafchromic film (EBT3), and a plastic scintillator detector (PSD, W1). Chamber, diodes, and PSD measurements were performed in a Wellhofer water tank, while films were irradiated in solid water at 100 cm source-to-surface distance and 10 cm depth. The collimator exchange effect was quantified for rectangular fields. Monte Carlo (MC) simulations of the measured configurations were also performed using the EGSnrc/DOSXYZnrc code. Output factors measured by the PSD and verified against film and MC calculations were chosen as the benchmark measurements. Compared with plastic scintillator detector (PSD), the small volume ion chamber (CC01) underestimated output factors by an average of -1.0% ± 4.9% (max. = -11.7% for 0.5 × 0.5 cm2 square field). The stereotactic diode (SFD) overestimated output factors by 2.5% ± 0.4% (max. = 3.3% for 0.5 × 1 cm2 rectangular field). The other diode detector (Edge) also overestimated the OFs by an average of 4.2% ± 0.9% (max. = 6.0% for 1 × 1 cm2 square field). Gafchromic film (EBT3) measure-ments and MC calculations agreed with the scintillator detector measurements within 0.6% ± 1.8% and 1.2% ± 1.5%, respectively. Across all the X and Y jaw combinations, the average collimator exchange effect was computed: 1.4% ± 1.1% (CC01), 5.8% ± 5.4% (SFD), 5.1% ± 4.8% (Edge diode), 3.5% ± 5.0% (Monte Carlo), 3.8% ± 4.7% (film), and 5.5% ± 5.1% (PSD). Small field detectors should be used with caution with a clear understanding of their behaviors, especially for FFF beams and small, elongated fields. The scintillator detector exhibited good agreement against Gafchromic film measurements and MC simulations over the range of field sizes studied. The collimator exchange effect was found to be impor-tant at these small field sizes. Detector-specific correction factors were computed using the scintillator measurements as the benchmark

    Targeting Accuracy of Image-Guided Radiosurgery for Intracranial Lesions: A Comparison Across Multiple Linear Accelerator Platforms

    Get PDF
    PURPOSE: To evaluate the overall positioning accuracy of image-guided intracranial radiosurgery across multiple linear accelerator platforms. METHODS: A computed tomography scan with a slice thickness of 1.0 mm was acquired of an anthropomorphic head phantom in a BrainLAB U-frame mask. The phantom was embedded with three 5-mm diameter tungsten ball bearings, simulating a central, a left, and an anterior cranial lesion. The ball bearings were positioned to radiation isocenter under ExacTrac X-ray or cone-beam computed tomography image guidance on 3 Linacs: (1) ExacTrac X-ray localization on a Novalis Tx; (2) cone-beam computed tomography localization on the Novalis Tx; (3) cone-beam computed tomography localization on a TrueBeam; and (4) cone-beam computed tomography localization on an Edge. Each ball bearing was positioned 5 times to the radiation isocenter with different initial setup error following the 4 image guidance procedures on the 3 Linacs, and the mean (µ) and one standard deviation (σ) of the residual error were compared. RESULTS: Averaged overall 3 ball bearing locations, the vector length of the residual setup error in mm (µ ± σ) was 0.6 ± 0.2, 1.0 ± 0.5, 0.2 ± 0.1, and 0.3 ± 0.1 on ExacTrac X-ray localization on a Novalis Tx, cone-beam computed tomography localization on the Novalis Tx, cone-beam computed tomography localization on a TrueBeam, and cone-beam computed tomography localization on an Edge, with their range in mm being 0.4 to 1.1, 0.4 to 1.9, 0.1 to 0.5, and 0.2 to 0.6, respectively. The congruence between imaging and radiation isocenters in mm was 0.6 ± 0.1, 0.7 ± 0.1, 0.3 ± 0.1, and 0.2 ± 0.1, for the 4 systems, respectively. CONCLUSIONS: Targeting accuracy comparable to frame-based stereotactic radiosurgery can be achieved with image-guided intracranial stereotactic radiosurgery treatment

    Evaluation and verification of the QFix Encompass couch insert for intracranial stereotactic radiosurgery

    Get PDF
    The QFix EncompassTM stereotactic radiosurgery (SRS) immobilization system consists of a thermoplastic mask that attaches to the couch insert to immobilize patients treated with intracranial SRS. This study evaluates the dosimetric impact and verifies a vendor provided treatment planning system (TPS) model in the Eclipse TPS. A thermoplastic mask was constructed for a Lucy 3D phantom, and was scanned with and without the EncompassTM system. Attenuation measurements were performed in the Lucy phantom with and without the insert using a pinpoint ion chamber for energies of 6xFFF, 10xFFF and 6X, with three field sizes (2 × 2, 4 × 4, and 6 × 6 cm2 ). The measurements were compared to two sets of calculations. The first set utilized the vendor provided Encompass TPS model (EncompassTPS ), which consists of two structures: the Encompass and Encompass base structure. Three HU values for the Encompass (200, 300, 400) and Encompass Base (-600, -500, -400) structures were evaluated. The second set of calculations consists of the Encompass insert included in the external body contour (EncompassEXT ) for dose calculation. The average measured percent attenuation in the posterior region of the insert ranged from 3.4%-3.8% for the 6xFFF beam, 2.9%-3.4% for the 10xFFF, and 3.3%-3.6% for the 6X beam. The maximum attenuation occurred at the region where the mask attaches to the insert, where attenuation up to 17% was measured for a 6xFFF beam. The difference between measured and calculated attenuation with either the EncompassEXT or EncompassTPS approach was within 0.5%. HU values in the EncompassTPS model that provided the best agreement with measurement was 400 for the Encompass structure and -400 for the Encompass base structure. Significant attenuation was observed at the area where the mask attaches to the insert. Larger differences can be observed when using few static beams compared to rotational treatment techniques

    Effects of Fiscal Decentralization on Garbage Classifications

    Get PDF
    China has been promoting garbage classification in its rural areas, yet it lacks financial appropriation and fiscal decentralization to support waste processing projects. Though the existing literature has suggested fiscal decentralization strategies between different local government levels, few of the studies ascertain garbage classification efficiency from a quantitative perspective. To bridge the gap, this study examines the optimal fiscal decentralization strategies for garbage classification. It uses an optimization model while considering decision makers’ requirements regarding the fund allocation amounts at different government levels and the classification ratios in villages as constraints and decisions, respectively. A three-stage heuristic algorithm is applied to determine optimal landfill locations and efficient classification ratios for the garbage processing system in rural China, with an analytical discussion on the propositions and properties of the model. Our analytical results suggest that 1) the theoretically optimal solution is conditionally achievable, 2) the applied algorithm can achieve the optimal solution faster when the relationship between governance costs and classification ratios reaches some mathematical conditions, and 3) there is always a potential for increasing the retained funds between different government levels or for reducing the total appropriation from the county government. The numerical experiment on a primary dataset from 12 towns and 143 villages in the Pingyuan county of Guangdong province, China, does not only affirm the qualitative results, but it also provides insights into the difficulties encountered during the implementation of the garbage classification policy in China’s rural areas

    Switchable collective pinning of flux quanta using magnetic vortex arrays

    Full text link
    We constructed a superconducting/ferromagnetic hybrid system in which the ordering of the pinning potential landscape for flux quanta can be manipulated. Flux pinning is induced by an array of magnetic nanodots in the magnetic vortex state, and controlled by the magnetic history. This allows switching on and off the collective pinning of the flux-lattice. In addition, we observed field-induced superconductivity that originates from the annihilation of flux quanta induced by the stray fields from the magnetic vortices.Comment: PDF file 18 pages including 5 figures, accepted for publication in Phys. Rev.

    Optimization of Treatment Geometry to Reduce Normal Brain Dose in Radiosurgery of Multiple Brain Metastases with Single-Isocenter Volumetric Modulated Arc Therapy

    Get PDF
    Treatment of patients with multiple brain metastases using a single-isocenter volumetric modulated arc therapy (VMAT) has been shown to decrease treatment time with the tradeoff of larger low dose to the normal brain tissue. We have developed an efficient Projection Summing Optimization Algorithm to optimize the treatment geometry in order to reduce dose to normal brain tissue for radiosurgery of multiple metastases with single-isocenter VMAT. The algorithm: (a) measures coordinates of outer boundary points of each lesion to be treated using the Eclipse Scripting Application Programming Interface, (b) determines the rotations of couch, collimator, and gantry using three matrices about the cardinal axes, (c) projects the outer boundary points of the lesion on to Beam Eye View projection plane, (d) optimizes couch and collimator angles by selecting the least total unblocked area for each specific treatment arc, and (e) generates a treatment plan with the optimized angles. The results showed significant reduction in the mean dose and low dose volume to normal brain, while maintaining the similar treatment plan qualities on the thirteen patients treated previously. The algorithm has the flexibility with regard to the beam arrangements and can be integrated in the treatment planning system for clinical application directly
    • …
    corecore