19 research outputs found

    Analyzing the Effects of MBPSS on the Transit Stability and High-Level Integration of Wind Farms during Fault Conditions

    Get PDF
    As the demand for renewable energy continues to increase, wind power has emerged as a prominent source of clean energy. However, incorporating wind energy into the power generation system at a high level can significantly impact the dynamic performance of the power system, resulting in increased uncertainties during operation. This study investigated the effectiveness of the Multi-Band Power System Stabilizer (MBPSS), a new power system stabilizer, in suppressing dynamic oscillations in a multi-machine power system connected to a wind farm. This research focused on analyzing the transient stability of a nine-bus network, commonly known as the Western System Coordinating Council (WSCC), integrated with a Doubly Fed Induction Generator (DFIG) using MATLAB/Simulink. The study evaluated the dynamic performance of the proposed system under fault conditions, including Line-to-Line-to-Line-to-Ground (LLLG) faults. Simulation results showed that MBPSS effectively dampened oscillations and improved the stability of the power system, even in the presence of severe faults and high-level integration of wind farms

    Fault Analysis of a Small PV/Wind Farm Hybrid System Connected to the Grid

    No full text
    The dynamic modeling, control, and simulation of renewable energy sources connected to the electrical grid are investigated in this study. Photovoltaic (PV) systems and wind systems connected to the power grid via the point of common connection (PCC) were the only two systems included in our study. Simulation and control methodologies are provided. For both PV arrays, the method of extracting maximum power point tracking (MPPT) is utilized to obtain the highest power under standard test conditions (STC: 1000 W/m2, 25 °C). A power electronics converter that can transform DC voltage into three-phase AC voltage is required to connect a PV system to the grid. Insulated gate bipolar transistors (IGBTs) are utilized in a three-level voltage source converter (VSC). The distribution network is connected to this three-phase VSC by way of a step-up transformer and filter. During synchronous rotation in the d−q reference frame, the suggested control for the three-level solar power system that is connected to the grid is constructed. To obtain a power factor as near to one as possible, the phase-locked loop (PLL) is employed to align the angle of the power grid voltage with the angle of the current coming from the inverter. Squirrel-cage induction generators (SCIGs), which are utilized as fixed speed generators and are linked directly to the power network, are the foundation of the wind system. Additionally, a pitch angle control approach is suggested to keep the wind turbine’s rotor speed stable. MATLAB/Simulink software is utilized to model and simulate the suggested hybrid system. Under fault scenarios such as the line to line to line to ground fault (LLLG fault), the suggested hybrid system’s dynamic performance is examined. The simulation results prove the ability to manage the small hybrid system that combines solar and wind power, as well as its dynamic performance

    A Low-Voltage AC, Low-Voltage DC, and High-Voltage DC Power Distribution System with Grid: Design and Analysis

    No full text
    Low-voltage (LV) and high-voltage (HV) DC distribution systems are being investigated as alternatives due to the growth of DC distribution energy resources (DER), DC loads such as solar and wind power systems, and energy storage sources (ESSs). Furthermore, an HV/LV DC distribution system offers various advantages, including lower conversion losses, an easier connecting strategy for DC DERs, and less complex power management techniques. As renewable energy sources are increasingly incorporated into the electrical grid, it is important to create novel, effective approaches for connecting such sources and loads. It would hence be effective to merge DC distribution with AC distribution to fulfill the energy demands of both DC and AC consumers. To this end, this study proposes a multizone design with four buses: low-voltage direct current (LVDC), high-voltage direct current (HVDC), low-voltage alternating current (LVAC), and an electrical grid. A model of this system that covers crucial elements, including power systems, DER systems, and power electronic devices, to serve as a foundation for the analysis and design of this architecture is proposed. MATLAB/Simulink is used to conduct a simulation study to verify the performance of the proposed design. In this study, a hybrid electrical grid with an LVDC, HVDC, and LVAC distribution network test is used and implemented. Additionally, a transient and steady-state characteristic analysis of the test system is performed

    Fault Analysis of a Small PV/Wind Farm Hybrid System Connected to the Grid

    No full text
    The dynamic modeling, control, and simulation of renewable energy sources connected to the electrical grid are investigated in this study. Photovoltaic (PV) systems and wind systems connected to the power grid via the point of common connection (PCC) were the only two systems included in our study. Simulation and control methodologies are provided. For both PV arrays, the method of extracting maximum power point tracking (MPPT) is utilized to obtain the highest power under standard test conditions (STC: 1000 W/m2, 25 °C). A power electronics converter that can transform DC voltage into three-phase AC voltage is required to connect a PV system to the grid. Insulated gate bipolar transistors (IGBTs) are utilized in a three-level voltage source converter (VSC). The distribution network is connected to this three-phase VSC by way of a step-up transformer and filter. During synchronous rotation in the d−q reference frame, the suggested control for the three-level solar power system that is connected to the grid is constructed. To obtain a power factor as near to one as possible, the phase-locked loop (PLL) is employed to align the angle of the power grid voltage with the angle of the current coming from the inverter. Squirrel-cage induction generators (SCIGs), which are utilized as fixed speed generators and are linked directly to the power network, are the foundation of the wind system. Additionally, a pitch angle control approach is suggested to keep the wind turbine’s rotor speed stable. MATLAB/Simulink software is utilized to model and simulate the suggested hybrid system. Under fault scenarios such as the line to line to line to ground fault (LLLG fault), the suggested hybrid system’s dynamic performance is examined. The simulation results prove the ability to manage the small hybrid system that combines solar and wind power, as well as its dynamic performance
    corecore