21 research outputs found

    Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients The ROADMAP Study 2-Year Results

    Get PDF
    OBJECTIVES The authors sought to provide the pre-specified primary endpoint of the ROADMAP (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients) trial at 2 years. BACKGROUND The ROADMAP trial was a prospective nonrandomized observational study of 200 patients (97 with a left ventricular assist device [LVAD], 103 on optimal medical management [OMM]) that showed that survival with improved functional status at 1 year was better with LVADs compared with OMM in a patient population of ambulatory New York Heart Association functional class IIIb/IV patients. METHODS The primary composite endpoint was survival on original therapy with improvement in 6-min walk distance \u3e= 75 m. RESULTS Patients receiving LVAD versus OMM had lower baseline health-related quality of life, reduced Seattle Heart Failure Model 1-year survival (78% vs. 84%; p = 0.012), and were predominantly INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile 4 (65% vs. 34%; p \u3c 0.001) versus profiles 5 to 7. More LVAD patients met the primary endpoint at 2 years: 30% LVAD versus 12% OMM (odds ratio: 3.2 [95% confidence interval: 1.3 to 7.7]; p = 0.012). Survival as treated on original therapy at 2 years was greater for LVAD versus OMM (70 +/- 5% vs. 41 +/- 5%; p \u3c 0.001), but there was no difference in intent-to-treat survival (70 +/- 5% vs. 63 +/- 5%; p = 0.307). In the OMM arm, 23 of 103 (22%) received delayed LVADs (18 within 12 months; 5 from 12 to 24 months). LVAD adverse events declined after year 1 for bleeding (primarily gastrointestinal) and arrhythmias. CONCLUSIONS Survival on original therapy with improvement in 6-min walk distance was superior with LVAD compared with OMM at 2 years. Reduction in key adverse events beyond 1 year was observed in the LVAD group. The ROADMAP trial provides risk-benefit information to guide patient- and physician-shared decision making for elective LVAD therapy as a treatment for heart failure. (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients [ROADMAP]; NCT01452802

    Primary results of long-term outcomes in the MOMENTUM 3 pivotal trial and continued access protocol study phase: a study of 2200 HeartMate 3 left ventricular assist device implants

    Get PDF
    AIM: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal-flow pump, over the HeartMate II axial-flow pump. We now evaluate HM3 LVAD outcomes in a single-arm prospective continuous access protocol (CAP) post-pivotal trial study. METHODS AND RESULTS: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2-year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71-1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra-aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68-1.16, P = 0.38). In a pooled analysis, the 2-year primary endpoint was similar between INTERMACS profiles 1-2 (\u27unstable\u27 advanced heart failure), profile 3 (\u27stable\u27 on inotropic therapy), and profiles 4-7 (\u27stable\u27 ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88-0.98, P = 0.006), with consequent decrease in hospitalization. CONCLUSIONS: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial

    Clinical outcomes and healthcare expenditures in the real world with left ventricular assist devices - The CLEAR-LVAD study

    Get PDF
    BACKGROUND: Several distinctly engineered left ventricular assist devices (LVADs) are in clinical use. However, contemporaneous real world comparisons have not been conducted, and clinical trials were not powered to evaluate differential survival outcomes across devices. OBJECTIVES: Determine real world survival outcomes and healthcare expenditures for commercially available durable LVADs. METHODS: Using a retrospective observational cohort design, Medicare claims files were linked to manufacturer device registration data to identify de-novo, durable LVAD implants performed between January 2014 and December 2018, with follow-up through December 2019. Survival outcomes were compared using a Cox proportional hazards model stratified by LVAD type and validated using propensity score matching. Healthcare resource utilization was analyzed across device types by using nonparametric bootstrap analysis methodology. Primary outcome was survival at 1-year and total Part A Medicare payments. RESULTS: A total of 4,195 de-novo LVAD implants were identified in fee-for-service Medicare beneficiaries (821 HeartMate 3; 1,840 HeartMate II; and 1,534 Other-VADs). The adjusted hazard ratio for mortality at 1-year (confirmed in a propensity score matched analysis) for the HeartMate 3 vs HeartMate II was 0.64 (95% CI; 0.52-0.79, p\u3c 0.001) and for the HeartMate 3 vs Other-VADs was 0.51 (95% CI; 0.42-0.63, p \u3c 0.001). The HeartMate 3 cohort experienced fewer hospitalizations per patient-year vs Other-VADs (respectively, 2.8 vs 3.2 EPPY hospitalizations, p \u3c 0.01) and 6.1 fewer hospital days on average (respectively, 25.2 vs 31.3 days, p \u3c 0.01). The difference in Medicare expenditures, conditional on survival, for HeartMate 3 vs HeartMate II was -10,722,p3˘c0.001(17.410,722, p \u3c 0.001 (17.4% reduction) and for HeartMate 3 vs Other-VADs was -17,947, p \u3c 0.001 (26.1% reduction). CONCLUSIONS: In this analysis of a large, real world, United States. administrative dataset of durable LVADs, we observed that the HeartMate 3 had superior survival, reduced healthcare resource use, and lower healthcare expenditure compared to other contemporary commercially available LVADs

    Quality of life and functional capacity outcomes in the MOMENTUM 3 trial at 6 months: A call for new metrics for left ventricular assist device patients

    No full text
    BACKGROUND: The Multicenter Study of MAGLEV Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) clinical trial demonstrated improved 6-month event-free survival, but a detailed analysis of health-related quality of life (HR-QOL) and functional capacity (FC) was not presented. Further, the effect of early serious adverse events (SAEs) on these metrics and on the general ability to live well while supported with a left ventricular assist system (LVAS) warrants evaluation. METHODS: FC (New York Heart Association [NYHA] and 6-minute walk test [6MWT]) and HR-QOL (European Quality of Life [EQ-5D-5L] and the Kansas City Cardiomyopathy [KCCQ]) assessments were obtained at baseline and 6 months after HeartMate 3 (HM3, n = 151; Abbott, Abbott Park, IL) or HeartMate II (HMII, n = 138; Abbott) implant as part of the MOMENTUM 3 clinical trial. Metrics were compared between devices and in those with and without events. The proportion of patients living well on an LVAS at 6 months, defined as alive with satisfactory FC (NYHA I/II or 6MWT \u3e 300 meters) and HR-QOL (overall KCCQ \u3e 50), was evaluated. RESULTS: Although the median (25th-75th percentile) patient KCCQ (change for HM3: +28 [10-46]; HMII: +29 [9-48]) and EQ-5D-5L (change for HM3: -1 [-5 to 0]; HMII: -2 [-6 to 0]) scores improved from baseline to 6 months (p \u3c 0.05), there were no differences between devices (p \u3e 0.05). Likewise, there was an equivalent improvement in 6MWT distance at 6 months in HM3 (+94 [1-274] meters] and HMII (+188[43-340 meters]) from baseline. In patients with SAEs (n = 188), 6MWTs increased from baseline (p \u3c 0.001), but gains for both devices were less than those without SAE (HM3: +74 [-9 to 183] meters with SAE vs +140 [35-329] meters without SAE; HMII: +177 [47-356] meters with SAE vs +192 [23-337] meters without SAE, both p \u3c 0.003). SAEs did not affect the 6-month HR-QOL scores. The living well end point was achieved in 145 HM3 (63%) and 120 HMII (68%) patients (p = 0.44). CONCLUSIONS: Gains in HR-QOL and FC were similar early after HM3 and HMII implant. 6MWT improvements were attenuated in patients experiencing SAEs, but HR-QOL metrics did not change. The development of left ventricular assist device-specific HR-QOL tools is needed to better characterize the effect of SAEs on a patient\u27s well-being. CLINICAL TRIAL NO: MOMENTUM 3 clinical trial #NCT02224755

    Five-Year Outcomes in Patients With Fully Magnetically Levitated vs Axial-Flow Left Ventricular Assist Devices in the MOMENTUM 3 Randomized Trial

    No full text
    Importance: Although durable left ventricular assist device (LVAD) therapy has emerged as an important treatment option for patients with advanced heart failure refractory to pharmacological support, outcomes, including survival, beyond 2 years remain poorly characterized. Objective: To report the composite end point of survival to transplant, recovery, or LVAD support free of debilitating stroke (Modified Rankin Scale score \u3e3) or reoperation to replace the pump 5 years after the implant in participants who received the fully magnetically levitated centrifugal-flow HeartMate 3 or axial-flow HeartMate II LVAD in the MOMENTUM 3 randomized trial and were still receiving LVAD therapy at the 2-year follow-up. Design, Setting, and Participants: This observational study was a 5-year follow-up of the MOMENTUM 3 trial, conducted in 69 US centers, that demonstrated superiority of the centrifugal-flow LVAD to the axial-flow pump with respect to survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump at 2 years. A total of 295 patients were enrolled between June 2019 to April 2021 in the extended-phase study, with 5-year follow-up completed in September 2021. Exposures: Of 1020 patients in the investigational device exemption per-protocol population, 536 were still receiving LVAD support at 2 years, of whom 289 received the centrifugal-flow pump and 247 received the axial-flow pump. Main Outcomes and Measures: There were 10 end points evaluated at 5 years in the per-protocol population, including a composite of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump between the centrifugal-flow and axial-flow pump groups and overall survival between the 2 groups. Results: A total of 477 patients (295 enrolled and 182 provided limited data) of 536 patients still receiving LVAD support at 2 years contributed to the extended-phase analysis (median age, 62 y; 86 [18%] women). The 5-year Kaplan-Meier estimate of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump in the centrifugal-flow vs axial-flow group was 54.0% vs 29.7% (hazard ratio, 0.55 [95% CI, 0.45-0.67]; P \u3c .001). Overall Kaplan-Meier survival was 58.4% in the centrifugal-flow group vs 43.7% in the axial-flow group (hazard ratio, 0.72 [95% CI, 0.58-0.89]; P = .003). Serious adverse events of stroke, bleeding, and pump thrombosis were less frequent in the centrifugal-flow pump group. Conclusions and Relevance: In this observational follow-up study of patients from the MOMENTUM 3 randomized trial, per-protocol analyses found that receipt of a fully magnetically levitated centrifugal-flow LVAD vs axial-flow LVAD was associated with a better composite outcome and higher likelihood of overall survival at 5 years. These findings support the use of the fully magnetically levitated LVAD. Trial Registration: ClinicalTrials.gov Identifier: NCT02224755 and NCT03982979

    Concurrent valvular procedures during left ventricular assist device implantation and outcomes: A comprehensive analysis of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 trial portfolio

    No full text
    BACKGROUND: Correction of valvular disease is often undertaken during left ventricular assist device (LVAD) implantation with uncertain benefit. We analyzed clinical outcomes with HeartMate 3 (HM3; Abbott) LVAD implantation in those with various concurrent valve procedures (HM3+VP) with those with an isolated LVAD implant (HM3 alone). METHODS: The study included 2200 patients with HM3 implanted within the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) trial portfolio who underwent 820 concurrent procedures among which 466 (21.8%) were HM3+VP. VPs included 101 aortic, 61 mitral, 163 tricuspid; 85 patients had multiple VPs. Perioperative complications, major adverse events, and survival were analyzed. RESULTS: Patients who underwent HM3+VP had higher-acuity Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles (1-2: 41% vs 31%) compared with no VPs (P \u3c .05). The cardiopulmonary bypass time (124 vs 76 minutes; P \u3c .0001) and hospital length of stay (20 vs 18 days; P \u3c .0001) were longer in HM3+VP. A higher incidence of stroke (4.9% vs 2.4%), bleeding (33.9% vs 23.8%), and right heart failure (41.5% vs 29.6%) was noted in HM3+VP at 0 to 30 days (P \u3c .01), with no difference in 30-day mortality (3.9% vs 3.3%) or 2-year survival (81.7% vs 80.8%). Analysis of individual VP showed no differences in survival compared to HM3 alone. No differences were noted among patients with either significant mitral (moderate or worse) or tricuspid (moderate or worse) regurgitation with or without corrective surgery. CONCLUSIONS: Concurrent VPs, commonly performed during LVAD implantation, are associated with increased morbidity during the index hospitalization, with no effect on short- and long-term survival. There is sufficient equipoise to consider a randomized trial on the benefit of commonly performed VPs (such as mitral or tricuspid regurgitation correction), during LVAD implantation

    Predictors of 5-Year Mortality in Patients Managed With a Magnetically Levitated Left Ventricular Assist Device

    No full text
    BACKGROUND: In advanced heart failure patients implanted with a fully magnetically levitated HeartMate 3 (HM3, Abbott) left ventricular assist device (LVAD), it is unknown how preimplant factors and postimplant index hospitalization events influence 5-year mortality in those able to be discharged. OBJECTIVES: The goal was to identify risk predictors of mortality through 5 years among HM3 LVAD recipients conditional on discharge from index hospitalization in the MOMENTUM 3 pivotal trial. METHODS: This analysis evaluated 485 of 515 (94%) patients discharged after implantation of the HM3 LVAD. Preimplant (baseline), implant surgery, and index hospitalization characteristics were analyzed individually, and as multivariable predictors for mortality risk through 5 years. RESULTS: Cumulative 5-year mortality in the cohort (median age: 62 years, 80% male, 65% White, 61% destination therapy due to transplant ineligibility) was 38%. Two preimplant characteristics (elevated blood urea nitrogen and prior coronary artery bypass graft or valve procedure) and 3 postimplant characteristics (hemocompatibility-related adverse events, ventricular arrhythmias, and estimated glomerular filtration rate \u3c60 mL/min/1.73 m(2) at discharge) were predictors of 5-year mortality. In 171 of 485 patients (35.3%) without any risk predictors, 5-year mortality was reduced to 22.6% (95% CI: 15.4%-32.7%). Even among those with 1 or more predictors, mortality was \u3c50% at 5 years (45.7% [95% CI: 39.0%-52.8%]). CONCLUSIONS: Long-term survival in successfully discharged HM3 LVAD recipients is largely influenced by clinical events experienced during the index surgical hospitalization in tandem with baseline factors, with mortality o

    Percutaneous venoarterial extracorporeal membrane oxygenation as a bridge to double valve implantation in acute biventricular heart failure with profound cardiogenic shock

    No full text
    A 71-year-old woman was admitted with acute hypoxic and hypercapnic respiratory failure and cardiogenic shock, secondary to acute on chronic biventricular systolic and diastolic congestive heart failure and severe aortic and mitral valve stenosis. She further presented with pulmonary hypertension and moderate-to-severe tricuspid regurgitation requiring high and increasing doses of vasopressors. The patient was percutaneously cannulated for venoarterial extracorporeal membrane oxygenation (VA-ECMO) and stabilized on ECMO, with a urine output of 17.3 L within the following 8 days. Balloon valvuloplasty and/or transcatheter aortic valve replacement were discussed but ruled out by the multidisciplinary team considering the mitral valve could not be fully addressed. Though lung function was not fully optimized, a window of opportunity was identified and used for double valve replacement on day 8 of VA-ECMO support. After a 24-hour vasoplegic period, the patient was extubated to continuous positive airway pressure and further transitioned to nasal cannula, following which she recovered well

    Outcomes in Smaller Body Size Adults After HeartMate 3 Left Ventricular Assist Device Implantation

    No full text
    BACKGROUND: Outcomes in patients with smaller body size following HeartMate 3 Left Ventricular Assist Device (HM3) implantation are not well characterized. We sought to evaluate outcomes in smaller vs. larger BSA patients in the MOMENTUM 3 pivotal trial and its Continued Access Protocol cohort. METHODS: The analysis cohort included 1015 HM3 patients divided into 2 groups: BSA≤1.70 m(2) (small patients, n=82) and BSA\u3e1.70 m(2) (large patients, n=933). The composite primary endpoint was survival at 2-years free of disabling stroke or reoperation to replace or remove a malfunctioning device. Adverse events were compared between groups. RESULTS: Smaller patients were more frequently women (56.1% vs. 17.7%, P\u3c.001), had lower prevalence of diabetes (28.1% vs. 43.9%, P=.005) and hypertension (51.2% vs. 71.9%, P\u3c.001), larger median indexed LVEDD (normalized by BSA, 40 vs. 33 mm/m(2), P\u3c.001), and lower median serum creatinine (1.1 vs. 1.3 mg/dl, P\u3c.001). The proportion of patients achieving the composite endpoint at 2-years was 77% in both groups (adjusted HR = 1.14 [95% confidence interval: 0.68-1.91], P=.62). Two-year adverse event rates were also similar between groups except for sepsis (6.1% vs. 14.9%, P=.029) and cardiac arrhythmias (24.4% vs. 35.3%, P=.005), which were higher in the larger patients. CONCLUSIONS: Outcomes following HM3 implantation were comparable between small and large patients. Smaller body size should not be used to deny HM3 implantation in patients who are otherwise suitable durable MCS candidates
    corecore