2,275 research outputs found
Feasibility of high-voltage systems for a very long drift in liquid argon TPCs
Designs of high-voltage (HV) systems for creating a drift electric field in
liquid argon TPCs are reviewed. In ongoing experiments systems capable of
approx. 100 kV are realised for a drift field of 0.5-1 kV/cm over a length of
up to 1.5 m. Two of them having different approaches are presented: (1) the
ICARUS-T600 detector having a system consisting of an external power supply, HV
feedthroughs and resistive voltage degraders and (2) the ArDM-1t detector
having a cryogenic Greinacher HV multiplier inside the liquid argon volume. For
a giant scale liquid argon TPC, a system providing 2 MV may be required to
attain a drift length of approx. 20 m. Feasibility of such a system is
evaluated by extrapolating the existing designs.Comment: 8 pages, 13 figures, to appear in Proc. of 1st International Workshop
towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba
(Japan), March 201
First operation and drift field performance of a large area double phase LAr Electron Multiplier Time Projection Chamber with an immersed Greinacher high-voltage multiplier
We have operated a liquid-argon large-electron-multiplier time-projection
chamber (LAr LEM-TPC) with a large active area of 76 40 cm and a
drift length of 60 cm. This setup represents the largest chamber ever achieved
with this novel detector concept. The chamber is equipped with an immersed
built-in cryogenic Greinacher multi-stage high-voltage (HV) multiplier, which,
when subjected to an external AC HV of 1 kV, statically
charges up to a voltage a factor of 30 higher inside the LAr vessel,
creating a uniform drift field of 0.5 kV/cm over the full drift length.
This large LAr LEM-TPC was brought into successful operation in the
double-phase (liquid-vapor) operation mode and tested during a period of
1 month, recording impressive three-dimensional images of very
high-quality from cosmic particles traversing or interacting in the sensitive
volume. The double phase readout and HV systems achieved stable operation in
cryogenic conditions demonstrating their good characteristics, which
particularly suit applications for next-generation giant-scale LAr-TPCs.Comment: 26 pages, 19 figure
Deformation of canonical morphisms and the moduli of surfaces of general type
In this article we study the deformation of finite maps and show how to use
this deformation theory to construct varieties with given invariants in a
projective space. Among other things, we prove a criterion that determines when
a finite map can be deformed to a one--to--one map. We use this criterion to
construct new simple canonical surfaces with different and . Our
general results enable us to describe some new components of the moduli of
surfaces of general type. We also find infinitely many moduli spaces having one component whose general point corresponds to a
canonically embedded surface and another component whose general point
corresponds to a surface whose canonical map is a degree 2 morphism.Comment: 32 pages. Final version with some simplifications and clarifications
in the exposition. To appear in Invent. Math. (the final publication is
available at springerlink.com
First operation and performance of a 200 lt double phase LAr LEM-TPC with a 40x76 cm^2 readout
In this paper we describe the design, construction, and operation of a first
large area double-phase liquid argon Large Electron Multiplier Time Projection
Chamber (LAr LEM-TPC). The detector has a maximum drift length of 60 cm and the
readout consists of a cm LEM and 2D projective anode to
multiply and collect drifting charges. Scintillation light is detected by means
of cryogenic PMTs positioned below the cathode. To record both charge and light
signals, we have developed a compact acquisition system, which is scalable up
to ton-scale detectors with thousands of charge readout channels. The
acquisition system, as well as the design and the performance of custom-made
charge sensitive preamplifiers, are described. The complete experimental setup
has been operated for a first time during a period of four weeks at CERN in the
cryostat of the ArDM experiment, which was equipped with liquid and gas argon
purification systems. The detector, exposed to cosmic rays, recorded events
with a single-channel signal-to-noise ratio in excess of 30 for minimum
ionising particles. Cosmic muon tracks and their -rays were used to
assess the performance of the detector, and to estimate the liquid argon purity
and the gain at different amplification fields.Comment: 23 pages, 21 figure
Secular theory of the orbital evolution of the young stellar disc in the Galactic Centre
We investigate the orbital evolution of a system of N mutually interacting
stars on initially circular orbits around the dominating central mass. We
include perturbative influence of a distant axisymmetric source and an extended
spherical potential. In particular, we focus on the case when the secular
evolution of orbital eccentricities is suppressed by the spherical
perturbation. By means of standard perturbation methods, we derive
semi-analytic formulae for the evolution of normal vectors of the individual
orbits. We find its two qualitatively different modes. Either the orbits
interact strongly and, under such circumstances, they become dynamically
coupled, precessing synchronously in the potential of the axisymmetric
perturbation. Or, if their mutual interaction is weaker, the orbits precess
independently, interchanging periodically their angular momentum, which leads
to oscillations of inclinations. We argue that these processes may have been
fundamental for the evolution of the disc of young stars orbiting the
supermassive black hole in the centre of the Milky Way.Comment: Accepted for publication in MNRAS; 11 pages, 6 figure
Stable operation with gain of a double phase Liquid Argon LEM-TPC with a 1 mm thick segmented LEM
In this paper we present results from a test of a small Liquid Argon Large
Electron Multiplier Time Projection Chamber (LAr LEM-TPC). This detector
concept provides a 3D-tracking and calorimetric device capable of charge
amplification, suited for next-generation neutrino detectors and possibly
direct Dark Matter searches. During a test of a 3~lt chamber equipped with a
1010~cm readout, cosmic muon data was recorded during three weeks
of data taking. A maximum gain of 6.5 was achieved and the liquid argon was
kept pure enough to ensure 20~cm drift (O(ppb)~O equivalent).Comment: 7 pages, 6 figures, to appear in Proc. of 1st International Workshop
towards the Giant Liquid Argon Charge Imaging Experiment (GLA2010), Tsukuba
(Japan), March 201
- …