61 research outputs found

    Performance of a Mobile 3D Camera to Evaluate Simulated Pathological Gait in Practical Scenarios

    Get PDF
    Three-dimensional (3D) cameras used for gait assessment obviate the need for bodily markers or sensors, making them particularly interesting for clinical applications. Due to their limited field of view, their application has predominantly focused on evaluating gait patterns within short walking distances. However, assessment of gait consistency requires testing over a longer walking distance. The aim of this study is to validate the accuracy for gait assessment of a previously developed method that determines walking spatiotemporal parameters and kinematics measured with a 3D camera mounted on a mobile robot base (ROBOGait). Walking parameters measured with this system were compared with measurements with Xsens IMUs. The experiments were performed on a non-linear corridor of approximately 50 m, resembling the environment of a conventional rehabilitation facility. Eleven individuals exhibiting normal motor function were recruited to walk and to simulate gait patterns representative of common neurological conditions: Cerebral Palsy, Multiple Sclerosis, and Cerebellar Ataxia. Generalized estimating equations were used to determine statistical differences between the measurement systems and between walking conditions. When comparing walking parameters between paired measures of the systems, significant differences were found for eight out of 18 descriptors: range of motion (ROM) of trunk and pelvis tilt, maximum knee flexion in loading response, knee position at toe-off, stride length, step time, cadence; and stance duration. When analyzing how ROBOGait can distinguish simulated pathological gait from physiological gait, a mean accuracy of 70.4%, a sensitivity of 49.3%, and a specificity of 74.4% were found when compared with the Xsens system. The most important gait abnormalities related to the clinical conditions were successfully detected by ROBOGait. The descriptors that best distinguished simulated pathological walking from normal walking in both systems were step width and stride length. This study underscores the promising potential of 3D cameras and encourages exploring their use in clinical gait analysis.</p

    Performance of a Mobile 3D Camera to Evaluate Simulated Pathological Gait in Practical Scenarios

    Get PDF
    Three-dimensional (3D) cameras used for gait assessment obviate the need for bodily markers or sensors, making them particularly interesting for clinical applications. Due to their limited field of view, their application has predominantly focused on evaluating gait patterns within short walking distances. However, assessment of gait consistency requires testing over a longer walking distance. The aim of this study is to validate the accuracy for gait assessment of a previously developed method that determines walking spatiotemporal parameters and kinematics measured with a 3D camera mounted on a mobile robot base (ROBOGait). Walking parameters measured with this system were compared with measurements with Xsens IMUs. The experiments were performed on a non-linear corridor of approximately 50 m, resembling the environment of a conventional rehabilitation facility. Eleven individuals exhibiting normal motor function were recruited to walk and to simulate gait patterns representative of common neurological conditions: Cerebral Palsy, Multiple Sclerosis, and Cerebellar Ataxia. Generalized estimating equations were used to determine statistical differences between the measurement systems and between walking conditions. When comparing walking parameters between paired measures of the systems, significant differences were found for eight out of 18 descriptors: range of motion (ROM) of trunk and pelvis tilt, maximum knee flexion in loading response, knee position at toe-off, stride length, step time, cadence; and stance duration. When analyzing how ROBOGait can distinguish simulated pathological gait from physiological gait, a mean accuracy of 70.4%, a sensitivity of 49.3%, and a specificity of 74.4% were found when compared with the Xsens system. The most important gait abnormalities related to the clinical conditions were successfully detected by ROBOGait. The descriptors that best distinguished simulated pathological walking from normal walking in both systems were step width and stride length. This study underscores the promising potential of 3D cameras and encourages exploring their use in clinical gait analysis.Biomechatronics & Human-Machine Contro

    Walking in postpoliomyelitis syndrome: The relationships between time-scored tests, walking in daily life and perceived mobility problems

    Get PDF
    Objective: To compare walking test results with walking in daily life, and to investigate the relationships between walking tests, walking activity in daily life, and perceived mobility problems in patients with post-poliomyelitis syndrome. Subjects: Twenty-four ambulant patients with post-poliomyelitis syndrome. Methods: Walking tests were performed at self-preferred and maximal speed. Walking activity was measured with an ambulatory activity monitor. Heart rate, step cadence and walking speed in the test and in daily life were compared. Walking speed in daily life was represented by the intensity of walking. Perceived mobility problems were assessed with the Nottingham Health Profile. Results: Heart rate during walking was lower in the test at self-preferred speed than in daily life (mean difference: 11.3 ± 10.4; p = 0.001). Self-preferred walking speed in the test and in daily life correlated significantly (r = 0.55; p = 0.04). In a sub-group with a test performance below the median value, test performance correlated significantly with walking activity. No significant correlation was found between perceived mobility problems and walking activity. Conclusion: Walking in daily life may be more demanding than walking under standardized conditions. Patients with post-poliomyelitis syndrome with the lowest test performance walked less in daily life. Patients do not necessarily match their activity pattern to their perceived mobility problems

    The Activ8 activity monitor: Validation of posture and movement classification

    Get PDF
    Introduction: To set up and guide interventions with the aim to increase physical activity and lower sedentary behavior valid monitoring of physical behavior is essential. The aim of this study was to evaluate the validity of the single-uni

    The accuracy of the detection of body postures and movements using a physical activity monitor in people after a stroke

    Get PDF
    Background: In stroke rehabilitation not only are the levels of physical activity important, but body postures and movements performed during one’s daily-life are also important. This information is provided by a new one-sensor accelerometer that is commercially available, low-cost, and user-friendly. The present study examines the accuracy of this activity monitor (Activ8) in detecting several classes of body postures and movements in people after a stroke. Methods: Twenty-five people after a stroke participated in an activity protocol with either basic activities or daily-life activities performed in a laboratory and/or at home. Participants wore an Activ8 on their less-affected thigh. The primary outcome was the difference in registered time for the merged class “upright position” (standing/walking/running) between the Activ8 and the video recording (the reference method). Secondar

    Accelerometric assessment of different dimensions of natural walking during the first year after stroke

    Get PDF
    Objectives: To describe the course of walking behaviour over a period of 1 year after stroke, using accelerometry, and to compare 1-year data with those from a healthy group. Design: One-year follow-up cohort study. Subjects: Twenty-three stroke patients and 20 age-matched healthy subjects. Methods: Accelerometer assessments were made in the participants' daily environment for 8 h/day during the 1st (T1), 12th (T2) and 48th (T3) weeks after stroke, and at one timepoint in healthy subjects. Primary outcomes were: percentage of time walking and upright (amount); mean duration and number of walking periods (distribution); step regularity and gait symmetry (quality); and walking speed. Results: Time walking, time upright, and number of walking bouts increased during T1 and T2 (p 0.30). Mean duration of walking periods showed no significant improvements (p > 0.30) during all phases. Step regularity, gait symmetry and gait speed showed a tendency to increase consistently from T1 to T3. At T3, amount and distribution variables reached the level of the healthy group, but significant differences remained (p < 0.02) in step regularity and gait speed. Conclusion: In this cohort, different outcomes of walking behaviour showed different patterns and levels of recovery, which supports the multi-dimensional character of gait

    Intramuscular botulinum toxin prior to comprehensive rehabilitation has no added value for improving motor impairments, gait kinematics and goal attainment in walking children with spastic cerebral palsy

    Get PDF
    Objective: Botulinum toxin (BoNT-A) is widely used in combined treatment for spastic cerebral palsy, but its added value preceding comprehensive rehabilitation for motor impairments, gait, and goal attainment has not been studied. Design: A comparative multi-centre trial, in which two groups underwent comprehensive rehabilitation (i.e. high-intensive functional physiotherapy, and indicated casting/orthoses). One group received intramuscular BoNT-A prior to rehabilitation, and the other group did not receive BoNT-A. Subjects/patients: Children with spastic cerebral palsy, Gross Motor Function Classification System (GMFCS) levels I–III, age range 4–12 years, indicated for BoNT-A treatment regarding mobility problems. Methods: Sixty-five children participated (37 boys), mean age 7.3 years (standard deviation (SD) 2.3, range 4–12 years), equally distributed across GMFCS levels. Forty-one children received BoNT-A+ comprehensive rehabilitation and 24 received comprehensive rehabilitation only. Functional leg muscle strength, passive range of motion, angle of catch, cer

    Current practices in clinical gait analysis in Europe:A comprehensive survey-based study from the European society for movement analysis in adults and children (ESMAC) standard initiative

    Get PDF
    BACKGROUND: Clinical gait analysis (CGA) is a systematic approach to comprehensively evaluate gait patterns, quantify impairments, plan targeted interventions, and evaluate the impact of interventions. However, international standards for CGA are currently lacking, resulting in various national initiatives. Standards are important to ensure safe and effective healthcare practices and to enable evidence-based clinical decision-making, facilitating interoperability, and reimbursement under national healthcare policies. Collaborative clinical and research work between European countries would benefit from common standards.RESEARCH OBJECTIVE: This study aimed to review the current laboratory practices for CGA in Europe.METHODS: A comprehensive survey was conducted by the European Society for Movement Analysis in Adults and Children (ESMAC), in close collaboration with the European national societies. The survey involved 97 gait laboratories across 16 countries. The survey assessed several aspects related to CGA, including equipment used, data collection, processing, and reporting methods.RESULTS: There was a consensus between laboratories concerning the data collected during CGA. The Conventional Gait Model (CGM) was the most used biomechanical model for calculating kinematics and kinetics. Respondents also reported the use of video recording, 3D motion capture systems, force plates, and surface electromyography. While there was a consensus on the reporting of CGA data, variations were reported in training, documentation, data preprocessing and equipment maintenance practices.SIGNIFICANCE: The findings of this study will serve as a foundation for the development of standardized guidelines for CGA in Europe.</p

    Detection of body postures and movements in ambulatory adults with cerebral palsy: a novel and valid measure of physical behaviour

    Get PDF
    BACKGROUND: Accurate measurement of physical behaviour is paramount to better understand lifestyle, health, and functioning, particularly in adults with physical disability as they may be at higher risk of sedentary lifestyle and subsequent negative health consequences. This study aimed: 1) to evaluate the criterion validity of a novel and clinically applicable activity monitor (AM, Activ8), in the detection of body postures and movements in adults with spastic cerebral palsy (CP); and 2) to evaluate the extent that the AM's positioning affects validity. METHODS: In this cross-sectional study, 14 ambulatory adults with CP [9 men; mean (SD) age, 35.4 (13.1) years] performed standardized activities while wearing three Activ8 monitors - frontolateral thigh (primary position), frontal thigh, and pant pocket - and being video recorded (criterion measure). AM activity output was compared to synchronized video recordings. Absolute (seconds) and relative [(video time-AM time)/mean time, %] time differences between methods were calculated. Relative time differences of < 10% were indicative of good validity. Comparison of AM attachment positions was completed using Spearman Rho correlation coefficients and Meng's tests. RESULTS: Criterion validity of the AM (frontolateral thigh) was good (average relative time differences: 0.25% for sitting, 4.69% for standing, 2.46% for walking, 1.96% for upright activity, 3.19% for cycling), except for running (34.6%). Spearman Rho correlation coefficients were greater between video/frontolateral thigh position than video/frontal thigh position and video/pant pocket position for body posture and movement categories sitting, standing, walking, and upright activity (p < 0.01 for all). CONCLUSIONS: The AM, positioned on the frontolateral thigh, demonstrated good criterion validity in ambulatory adults with CP. Though the Activ8 offers potential as an objective measure of physical activity, appropriate positioning is paramount for valid measurement
    • …
    corecore