124 research outputs found
Validation of a same-day real-time PCR method for screening of meat and carcass swabs for Salmonella
<p>Abstract</p> <p>Background</p> <p>One of the major sources of human <it>Salmonella </it>infections is meat. Therefore, efficient and rapid monitoring of <it>Salmonella </it>in the meat production chain is necessary. Validation of alternative methods is needed to prove that the performance is equal to established methods. Very few of the published PCR methods for <it>Salmonella </it>have been validated in collaborative studies. This study describes a validation including comparative and collaborative trials, based on the recommendations from the Nordic organization for validation of alternative microbiological methods (NordVal) of a same-day, non-commercial real-time PCR method for detection of <it>Salmonella </it>in meat and carcass swabs.</p> <p>Results</p> <p>The comparative trial was performed against a reference method (NMKL-71:5, 1999) using artificially and naturally contaminated samples (60 minced veal and pork meat samples, 60 poultry neck-skins, and 120 pig carcass swabs). The relative accuracy was 99%, relative detection level 100%, relative sensitivity 103% and relative specificity 100%. The collaborative trial included six laboratories testing minced meat, poultry neck-skins, and carcass swabs as un-inoculated samples and samples artificially contaminated with 1–10 CFU/25 g, and 10–100 CFU/25 g. Valid results were obtained from five of the laboratories and used for the statistical analysis. Apart from one of the non-inoculated samples being false positive with PCR for one of the laboratories, no false positive or false negative results were reported. Partly based on results obtained in this study, the method has obtained NordVal approval for analysis of <it>Salmonella </it>in meat and carcass swabs. The PCR method was transferred to a production laboratory and the performance was compared with the BAX <it>Salmonella </it>test on 39 pork samples artificially contaminated with <it>Salmonella</it>. There was no significant difference in the results obtained by the two methods.</p> <p>Conclusion</p> <p>The real-time PCR method for detection of <it>Salmonella </it>in meat and carcass swabs was validated in comparative and collaborative trials according to NordVal recommendations. The PCR method was found to perform well. The test is currently being implemented for screening of several hundred thousand samples per year at a number of major Danish slaughterhouses to shorten the post-slaughter storage time and facilitate the swift export of fresh meat.</p
A Comparison between Recombinant Activated Factor VII (Aryoseven) and Novoseven in Patients with Congenital Factor VII Deficiency
In order to establish the efficacy and biosimilar nature of AryoSeven to NovoSeven in the treatment of congenital factor VII (FVII) deficiency, patients received either agent at 30 1/4g/kg, intravenously per week for 4 weeks, in a randomized fashion. The primary aim was to compare FVII:coagulation activity (FVII:C), 20 minutes after recombinant activated FVII (rFVIIa) injection, in the 2 groups. A secondary measure was self-reported bleeding. The median interquartile baseline range of the plasma level of activated FVII (FVIIa) activity in the 2 groups was 1.6 (1.1-14.0) IU/dL and 5.0 (1.1-25.5) IU/dL. All patients achieved levels of FVIIa (FVII:C) >30 IU/dL, 20 minutes after the injection of rFVIIa. Bleeding was similar between the 2 groups, with a comparable decrease in severity and frequency compared to the last month prior to treatment. AryoSeven is similar to NovoSeven in increasing postinjection FVIIa activity as well as in clinical safety and efficacy. © The Author(s) 2014
Enabling Passive Immunization as an Alternative to Antibiotics for Controlling Enteric Infections in Production Animals
Enteric infections cause major problems in most intensive animal production sectors, including poultry, pigs and cattle, leading to disease, reduced production and compromised welfare. In addition some of these infections are zoonotic, and they are to a large extent responsible for the continued massive use of antibiotics in food animals. Thus there is a pressing need for economically feasible, efficient, non-antibiotics based means for controlling the problem. Passive immunization has been known for decades as an efficient way of endowing humans or animals with short-term (weeks) immunity. To control enteric infections by passive immunization a bolus of immunoglobulin may simply be administered orally. For this to work, large amounts of active immunoglobulins are needed. To be a real alternative to antibiotics the price of the immunoglobulin product needs to be low. We combined an efficient and mild high-capacity method for extracting immunoglobulins directly from raw materials like milk, whey and blood plasma with a novel method for stabilizing activity. In a first experiment a total of 15 kg unstabilized bovine immunoglobulin was purified from whey (35.000 liters) and administered to colostrum-deprived calves (225-300 g pr calf during the first 24 hours after birth). No difference in resulting immunoglobulin serum concentration, weight gain or disease frequency were seen in this group of calves compared to a control group given full access to high-quality colostrum. The effect of orally administered bovine immunoglobulin is currently being tested in a calf herd with persistent diarrhea problems. Furthermore, it was shown in a Campylobacter challenge model in chickens that caecal and faecal counts of Campylobacter were between 0.5 and 1.0 logs lower in birds when given 200 mg avian immunoglobulins orally together with the challenge (at day 21 of age) compared to a placebo group receiving immunoglobulin with no reactivity against Campylobacter. While clearly preliminary, these results show that immunoglobulin can be produced from renewable sources at a price enabling passive immunization as a viable strategy for control of infectious diseases in the intensive animal production, with the potential to significantly reduce antibiotics consumption
Fibrinogen concentrate for treatment of bleeding and surgical prophylaxis in congenital fibrinogen deficiency patients
Background: Congenital fibrinogen deficiency is an ultra-rare disorder in which patients can experience severe and/or frequent bleeding episodes (BEs). Here, we present the largest prospective study to date on the treatment of this disorder. Methods: Hemostatic efficacy of human fibrinogen concentrate (HFC; FIBRYGA\uae, Octapharma AG) for treatment of bleeding or surgical prophylaxis was assessed by investigators and adjudicated by an independent data monitoring and endpoint adjudication committee (IDMEAC) according to a four-point scale, using objective criteria. Thromboelastometry maximum clot firmness (MCF) was also determined. Results: Twenty-five afibrinogenemia patients were treated with HFC: 24 for on-demand treatment of 89 BEs, and nine as prophylaxis for 12 surgeries. For BEs, treatment success (rating of excellent or good) evaluated by investigators was 96.6% (90% confidence interval [CI], 0.92-0.99; two missing ratings, classified as failures) and by the IDMEAC was 98.9% (90% CI, 0.95-0.999). Mean \ub1 standard deviation (SD) increase in MCF was 5.8 \ub1 2.5 mm one hour after the first HFC infusion (mean \ub1 SD dose, 61.88 \ub1 11.73 mg/kg). For the 12 surgeries (median [range] HFC dose/surgery, 85.80 mg/kg [34.09-225.36]), intraoperative and postoperative treatment success were both rated 100% (90% CI, 0.82-1.00) by investigators and the IDMEAC. Three adverse events were possibly treatment related, including a moderate case of thrombosis. There were no deaths, no severe allergic or hypersensitivity reactions, and no clinical evidence of neutralizing antifibrinogen antibodies. Conclusions: Human fibrinogen concentrate was efficacious for on-demand treatment of bleeding and as surgical prophylaxis, with a favorable safety profile, in patients with congenital afibrinogenemia
Evaluation of a novel real-time PCR test based on the ssrA gene for the identification of group B streptococci in vaginal swabs
<p>Abstract</p> <p>Background</p> <p>Despite the implementation of prevention guidelines, early-onset group B streptococci (GBS) disease remains a cause of neonatal morbidity and mortality worldwide. Strategies to identify women who are at risk of transmitting GBS to their infant and the administration of intrapartum antibiotics have greatly reduced the incidence of neonatal GBS disease. However, there is a requirement for a rapid diagnostic test for GBS that can be carried out in a labour ward setting especially for women whose GBS colonisation status is unknown at the time of delivery. We report the design and evaluation of a real-time PCR test (<it>RiboSEQ </it>GBS test) for the identification of GBS in vaginal swabs from pregnant women.</p> <p>Methods</p> <p>The qualitative real-time PCR <it>RiboSEQ </it>GBS test was designed based on the bacterial <it>ssrA </it>gene and incorporates a competitive internal standard control. The analytical sensitivity of the test was established using crude lysate extracted from serial dilutions of overnight GBS culture using the IDI Lysis kit. Specificity studies were performed using DNA prepared from a panel of GBS strains, related streptococci and other species found in the genital tract environment. The <it>RiboSEQ </it>GBS test was evaluated on 159 vaginal swabs from pregnant women and compared with the GeneOhm™ StrepB Assay and culture for the identification of GBS.</p> <p>Results</p> <p>The <it>RiboSEQ </it>GBS test is specific and has an analytical sensitivity of 1-10 cell equivalents. The <it>RiboSEQ </it>GBS test was 96.4% sensitive and 95.8% specific compared to "gold standard" culture for the identification of GBS in vaginal swabs from pregnant women. In this study, the <it>RiboSEQ </it>GBS test performed slightly better than the commercial BD GeneOhm™ StrepB Assay which gave a sensitivity of 94.6% and a specificity of 89.6% compared to culture.</p> <p>Conclusion</p> <p>The <it>RiboSEQ </it>GBS test is a valuable method for the rapid, sensitive and specific detection of GBS in pregnant women. This study also validates the <it>ssrA </it>gene as a suitable and versatile target for nucleic acid-based diagnostic tests for bacterial pathogens.</p
Development and optimization of quantitative PCR for the diagnosis of invasive aspergillosis with bronchoalveolar lavage fluid
Background: The diagnosis of invasive pulmonary aspergillosis (IPA) remains challenging. Culture and histopathological examination of bronchoalveolar lavage (BAL) fluid are useful but have suboptimal sensitivity and in the case of culture may require several days for fungal growth to be evident. Detection of Aspergillus DNA in BAL fluid by quantitative PCR (qPCR) offers the potential for earlier diagnosis and higher sensitivity. It is important to adopt quality control measures in PCR
assays to address false positives and negatives which can hinder accurate evaluation of diagnostic performance.
Methods: BAL fluid from 94 episodes of pneumonia in 81 patients was analyzed. Thirteen episodes were categorized as proven or probable IPA using Mycoses Study Group criteria. The pellet and
the supernatant fractions of the BAL were separately assayed. A successful extraction was confirmed with a human 18S rRNA gene qPCR. Inhibition in each qPCR was measured using an exogenous DNA based internal amplification control (IAC). The presence of DNA from pathogens in the Aspergillus genus was detected using qPCR targeting fungal 18S rRNA gene.
Results: Human 18S rRNA gene qPCR confirmed successful DNA extraction of all samples. IAC detected some degree of initial inhibition in 11 samples. When culture was used to diagnose IPA,
the sensitivity and specificity were 84.5% and 100% respectively. Receiver-operating characteristic analysis of qPCR showed that a cutoff of 13 fg of Aspergillus genomic DNA generated a sensitivity,
specificity, positive and negative predictive value of 77%, 88%, 50%, 96% respectively. BAL pellet and supernatant analyzed together resulted in sensitivity and specificity similar to BAL pellet alone.
Some patients did not meet standard criteria for IPA, but had consistently high levels of Aspergillus DNA in BAL fluid by qPCR.
Conclusion: The Aspergillus qPCR assay detected Aspergillus DNA in 76.9% of subjects with proven or probable IPA when the concentrated BAL fluid pellet fraction was used for diagnosis. There was
no benefit from analyzing the BAL supernatant fraction. Use of both extraction and amplification controls provided optimal quality control for interpreting qPCR results and therefore may increase our understanding of the true potential of qPCR for the diagnosis of IPA.Supported by NIH grant R01 AI054703 from the National Institute of Allergy and Infectious Diseases
Impact of Dietary Gluten on Regulatory T Cells and Th17 Cells in BALB/c Mice
Dietary gluten influences the development of type 1 diabetes (T1D) and a gluten-free (GF) diet has a protective effect on the development of T1D. Gluten may influence T1D due to its direct effect on intestinal immunity; however, these mechanisms have not been adequately studied. We studied the effect of a GF diet compared to a gluten-containing standard (STD) diet on selected T cell subsets, associated with regulatory functions as well as proinflammatory Th17 cells, in BALB/c mice. Furthermore, we assessed diet-induced changes in the expression of various T cell markers, and determined if changes were confined to intestinal or non-intestinal lymphoid compartments. The gluten-containing STD diet led to a significantly decreased proportion of γδ T cells in all lymphoid compartments studied, although an increase was detected in some γδ T cell subsets (CD8+, CD103+). Further, it decreased the proportion of CD4+CD62L+ T cells in Peyer's patches. Interestingly, no diet-induced changes were found among CD4+Foxp3+ T cells or CD3+CD49b+cells (NKT cells) and CD3−CD49b+ (NK) cells. Mice fed the STD diet showed increased proportions of CD4+CD45RBhigh+ and CD103+ T cells and a lower proportion of CD4+CD45RBlow+ T cells in both mucosal and non-mucosal compartments. The Th17 cell population, associated with the development of autoimmunity, was substantially increased in pancreatic lymph nodes of mice fed the STD diet. Collectively, our data indicate that dietary gluten influences multiple regulatory T cell subsets as well as Th17 cells in mucosal lymphoid tissue while fewer differences were observed in non-mucosal lymphoid compartments
Rapid diagnostic tests as a source of DNA for Plasmodium species-specific real-time PCR
<p>Abstract</p> <p>Background</p> <p>This study describes the use of malaria rapid diagnostic tests (RDTs) as a source of DNA for <it>Plasmodium </it>species-specific real-time PCR.</p> <p>Methods</p> <p>First, the best method to recover DNA from RDTs was investigated and then the applicability of this DNA extraction method was assessed on 12 different RDT brands. Finally, two RDT brands (OptiMAL Rapid Malaria Test and SDFK60 malaria Ag <it>Plasmodium falciparum</it>/Pan test) were comprehensively evaluated on a panel of clinical samples submitted for routine malaria diagnosis at ITM. DNA amplification was done with the 18S rRNA real-time PCR targeting the four <it>Plasmodium </it>species. Results of PCR on RDT were compared to those obtained by PCR on whole blood samples.</p> <p>Results</p> <p>Best results were obtained by isolating DNA from the proximal part of the nitrocellulose component of the RDT strip with a simple DNA elution method. The PCR on RDT showed a detection limit of 0.02 asexual parasites/μl, which was identical to the same PCR on whole blood. For all 12 RDT brands tested, DNA was detected except for one brand when a low parasite density sample was applied. In RDTs with a plastic seal covering the nitrocellulose strip, DNA extraction was hampered. PCR analysis on clinical RDT samples demonstrated correct identification for single species infections for all RDT samples with asexual parasites of <it>P. falciparum </it>(n = 60), <it>Plasmodium vivax </it>(n = 10), <it>Plasmodium ovale </it>(n = 10) and <it>Plasmodium malariae </it>(n = 10). Samples with only gametocytes were detected in all OptiMAL and in 10 of the 11 SDFK60 tests. None of the negative samples (n = 20) gave a signal by PCR on RDT. With PCR on RDT, higher Ct-values were observed than with PCR on whole blood, with a mean difference of 2.68 for OptiMAL and 3.53 for SDFK60. Mixed infections were correctly identified with PCR on RDT in 4/5 OptiMAL tests and 2/5 SDFK60 tests.</p> <p>Conclusions</p> <p>RDTs are a reliable source of DNA for <it>Plasmodium </it>real-time PCR. This study demonstrates the best method of RDT fragment sampling for a wide range of RDT brands in combination with a simple and low cost extraction method, allowing RDT quality control.</p
- …