77 research outputs found
A New Adaptive Fuzzy PID Control Method and Its Applicance in FCBTM
The process of tension control for material testing using the Flexible ircuit Board testing machine (FCBTM) is featured with multi-variable, nonlinearity, ime delays and time variation. In order to ensure the tension precision, the stability of ervo motor’ speed and the reliability of test results, this paper establishes an accurate ystem model for the FCBTM, in which a novel three-dimensional adaptive fuzzy ID controller is designed. Specially, the simulation results show that the proposed daptive fuzzy control method is not only robust to the external disturbance but also ith more excellent dynamic and steady-state characteristics than traditional ones
Quantum phases of SrCu2(BO3)2 from high-pressure thermodynamics
We report heat capacity measurements of SrCu(BO) under high
pressure along with simulations of relevant quantum spin models and map out the
phase diagram of the material. We find a first-order quantum phase
transition between the low-pressure quantum dimer paramagnet and a phase with
signatures of a plaquette-singlet state below T = K. At higher pressures,
we observe a transition into a previously unknown antiferromagnetic state below
K. Our findings can be explained within the two-dimensional
Shastry-Sutherland quantum spin model supplemented by weak inter-layer
couplings. The possibility to tune SrCu(BO) between the
plaquette-singlet and antiferromagnetic states opens opportunities for
experimental tests of quantum field theories and lattice models involving
fractionalized excitations, emergent symmetries, and gauge fluctuations.Comment: 6 pages + 8 pages supplemental informatio
Temperature Control via Affine Nonlinear Systems for Intermediate Point of Supercritical Once-Through Boiler Units
For the operation of the supercritical once-through boiler generation units, the control of the temperature
at intermediate point (IPT) is highly significant. IPT is the steam temperature at the outlet of the separator. Currently, PID control algorithms are widely adopted for the IPT control. However, PID cannot achieve the optimal performances as the units’ dynamic characteristic changes at different working points due to the severe nonlinearity. To address the problem, a new control algorithm using affine nonlinear system is adopted for a 600 MW unit in this paper. In order to establish the model of IPT via affine nonlinear system, the simplified mechanism equations on the evaporation zone and steam separator of the unit are established. Then, the feedback linearizing control law can be obtained. Full range simulations with the load varying from 100% to 30% are conducted. To verify the effectiveness of the proposed control algorithm, the performance of the new method is compared with the results of
the PID control. The feed-water flow disturbances are considered in simulations of both of the two control methods. The comparison shows the new method has a better performance with a quicker response time and a smaller overshoot, which demonstrates the potential improvement for the supercritical once-through boiler generation unit control
Synchronization of Hybrid Microgrids with Communication Latency
A distributed cooperative control scheme is proposed in order to implement a distributed secondary control for hybrid lossy microgrids. The designed distributed control is able to synchronize the frequency of inverse-based distributed generators (DGs) and minisynchronous generators (MSGs/SGs) to the desired state with a virtual leader DG/SG (reference value) in a distribution switching network under the existence of time-varying communication delays. The secondary control stage selects suitable frequencies of each DG/SG such that they can be synchronized at the desired set point. Using the proposed algorithm, each DG/SG only needs to communicate with its neighboring DGs/SGs intermittently even if the communication networks are local, the topology is time-varying, and the communication delays may exist. Therefore, the failure of a single DG/SG will not produce the failing down of the whole system. Sufficient conditions on the requirements for the network connectivity and the delays boundedness which guarantees the stability and synchronization of the controlled hybrid lossy microgrid power systems are presented. The feasibility of the proposed control methodology is verified by the simulation of a given lossy microgrid test system
Multiband superconductivity and a deep gap minimum evidenced by specific heat in KCa(FeNi)AsF
Specific heat can explore low-energy quasiparticle excitations of
superconductors, so it is a powerful tool for bulk measurement on the
superconducting gap structure and pairing symmetry. Here, we report an in-depth
investigation on the specific heat of the multiband superconductors
KCa(FeNi)AsF ( = 0, 0.05, 0.13) single crystals
and the overdoped non-superconducting one with = 0.17. For the samples with
= 0 and = 0.05, the magnetic field induced specific heat coefficient
in the low temperature limit increases rapidly below 2 T,
then it rises slowly above 2 T. Using the non-superconducting sample with =
0.17 as a reference, and applying a mixed model that combines Debye and
Einstein modes, the specific heat of phonon background for various
superconducting samples can be fitted and the detailed information of the
electronic specific heat is obtained. Through comparative analyses, it is found
that the energy gap structure including two -wave gaps and an extended
-wave gap with large anisotropy can reasonably describe the electronic
specific heat data. According to these results, we suggest that at least one
anisotropic superconducting gap with a deep gap minimum should exist in this
multiband system. With the doping of Ni, the of the sample decreases
along with the decrease of the large -wave gap, but the extended -wave
gap increases due to the enlarged electron pockets via adding more electrons.
Despite these changes, the general properties of the gap structure remain
unchanged versus doping Ni. In addition, the calculation of condensation energy
of the parent and doped samples shows the rough consistency with the
correlation of with = 3-4, which is beyond the
understanding of the BCS theory
- …