23 research outputs found
Degrowth within â Aligning circular economy and strong sustainability narratives
This perspective calls for building greater understanding of overlapping and conflicting considerations between the sustainability principles that inform current conceptions of circular economy and degrowth. We contend that scholars and practitioners need to be pragmatic and to recognize evident ideological differences, but simultaneously to acknowledge beneficial similarities and complements. The common aim of both frameworks â to change business-as-usual and to enable human society to operate within ecological planetary boundaries â will likely engender opportunities to formulate new solutions. Management of the inherent tensions, such as the scale and scope of rebound effects, will continue to pose challenges. However, with thoughtful dialogue, commitment to respectful discourse, and more refined articulation we are confident that progress will be made. By building on synergies and seeking holistic strategies, the academic community, along with its transdisciplinary partners, can advance strong global sustainability efforts
Magnetic Resonance Imaging of the Axial Skeleton in Patients With Spondyloarthritis: Distribution Pattern of Inflammatory and Structural Lesions
Purpose:
Spondyloarthritis is a chronic inflammatory disorder of the musculoskeletal system driven by systemic enthesitis and typically involving the axial skeleton, ie, the spine and the sacroiliac joints. The purpose of this study was to assess the distribution pattern of inflammatory and structural magnetic resonance imaging (MRI) findings in spondyloarthritis.
Methods:
Retrospective study of 193 patients with axial spondyloarthritis who received MRI of the spine and the sacroiliac joints. We quantitatively assessed inflammatory and structural lesions using established MRI-based scoring methods. The significance of the differences between gender, HLA-B27 status, and spine and sacroiliac involvement was determined.
Results:
In total, 174 patients (90.2%) showed a sacroiliac involvement and 120 patients (62.2%) a combined involvement of the sacroiliac joints and the spine. An isolated sacroiliac involvement was found in 54 patients (28.0%) and an isolated spine involvement in 19 patients (9.8%). The sacroiliac joint was significantly more involved in men than in women (Pâ<â.01), and men had significantly higher scores for structural lesions (Pâ<â.001). The subgroup of HLA-B27âpositive patients showed a significantly higher percentage of sacroiliac involvement compared with HLA-B27ânegative patients (Pâ<â.05).
Conclusions:
Spondyloarthritis is a systemic disorder predominantly involving the sacroiliac joints. However, the entire axial skeleton may be affected. In particular, HLA-B27ânegative women show atypical manifestations without sacroiliac involvement. Magnetic resonance imaging in spondyloarthritis should cover the entire axial skeleton, ie, sacroiliac joints and the spine to meet the pathophysiology of this disorder and capture the true extent of inflammatory and structural lesions
Diagnostic value of a hand-carried ultrasound device for free intra-abdominal fluid and organ lacerations in major trauma patients
Background:
Technological progress has led to the introduction of hand-carried ultrasound (HCU) imagers in clinical workflow. The aim of this study is to analyse whether examination with a HCU device is a rapid and reliable alternative to contrast-enhanced multidetector CT (MDCT) scans in diagnosis of free intra-abdominal fluid and organ lacerations in major trauma patients.
Methods:
31 major trauma patients with an injury severity score >15 and the necessity of a MDCT scan (standard of reference) were enrolled prospectively to this study, and additionally examined with a HCU, according to âfocused assessment with sonography for traumaâ principles for the assessment of organ lacerations and free intra-abdominal fluid. The HCU device employed was of the latest generation. Statistical analysis was performed using PASW V.18.
Results:
Four patients were diagnosed with free intra-abdominal fluid (prevalence 12.9%). HCU showed a sensitivity and specificity of 75% and 100%, respectively. Positive predictive value and negative predictive value were 100% and 96%, respectively. Five patients had organ lacerations (prevalence 16.1%). In these cases, the HCU was able to detect organ lacerations with a sensitivity and specificity of 80% and 100%, respectively. Therefore, a positive predictive value and negative predictive value of 100% and 96%, respectively, were calculated.
Conclusion:
In major trauma patients, examination with HCU according to the âfocused assessment with sonography for traumaâ principles for the diagnosis of organ lacerations and free intra-abdominal fluid is a reliable and rapid alternative to MDCT scans and can help save precious time in emergency situations, and should, additionally, be evaluated in the pre-clinical workflow
Volume Navigation with Contrast Enhanced Ultrasound and Image Fusion for Percutaneous Interventions: First Results
Percutaneous biopsies and drainages, even of small lesions involving complex access pathways, can be accomplished with a high success rate by using 3D real time image fusion together with real time needle tracking
Dynamic magnetic resonance defecography in 10 asymptomatic volunteers
AIM: Evaluation of the wide range of normal findings in asymptomatic women undergoing dynamic magnetic resonance (MR) defecography.
METHODS: MR defecography of 10 healthy female volunteers (median age: 31 years) without previous pregnancies or history of surgery were evaluated. The rectum was filled with 180 mL gadolinium ultrasound gel mixture. MR defecography was performed in the supine position. The pelvic floor was visualized with a dynamic T2-weighted sagittal plane where all relevant pelvic floor organs were acquired during defecation. The volunteers were instructed to relax and then to perform straining maneuvers to empty the rectum. The pubococcygeal line (PCGL) was used as the line of reference. The movement of pelvic floor organs was measured as the vertical distance to this reference line. Data were recorded in the resting position as well as during the defecation process with maximal straining. Examinations were performed and evaluated by two experienced abdominal radiologists without knowledge of patient history.
RESULTS: Average position of the anorectal junction was located at -5.3 mm at rest and -29.9 mm during straining. The anorectal angle widened significantly from 93° at rest to 109° during defecation. A rectocele was diagnosed in eight out of 10 volunteers showing an average diameter of 25.9 mm. The bladder base was located at a position of +23 mm at rest and descended to -8.1 mm during defecation in relation to the PCGL. The bladder base moved below the PCGL in six out of 10 volunteers, which was formally defined as a cystocele. The uterocervical junction was located at an average level of +43.1 mm at rest and at +7.9 mm during straining. The uterocervical junction of three volunteers fell below the PCGL; described formally as uterocervical prolapse.
CONCLUSION: Based on the range of standard values in asymptomatic volunteers, MR defecography values for pathological changes have to be re-evaluated
Radiological outcome of postoperative sagittal balance on standing radiographs in comparison to intraoperative radiographs in prone position when performing lumbar spinal fusion
Aim of this study is to show the outcome of postoperatively measured lumbar lordosis in upright position in comparison to the intraoperatively estimated lumbar lordosis in prone position, as the lumbar lordosis is one of the most important factors for the clinical outcome after spinal fusion. Eighty-two patients, receiving lumbar fusion were included in this retrospective study. Intraoperative radiographs were scanned. Then radiographs of the whole spine pre- and postoperatively, as well as 1 year after surgery were measured by a spine surgeon and a radiologist. The visible segment lordosis angles were measured and compared (L2-S1, L3-S1, L4-S1, L5-S1). In addition, the pelvic parameters pelvic incidence, pelvic tilt and sacral slope were measured pre- and postoperatively. The intraobserver reliability was almost perfect. The mean lordosis angle L4-S1 was 32.6A degrees A +/- 7.8A degrees intraoperatively and 29A degrees A +/- 10.8A degrees postoperatively. A linear correlation of these two measurements can be seen. In mean, the postoperative lordosis is 4A degrees smaller than intraoperatively. This trend can also be seen in the level L3-S1. In levels L2-S1 and L5-S1 the postoperative values were slightly higher than intraoperatively, but without any significance. Also, 1 year after surgery there were no significant changes in global lumbar lordosis. Measuring lordosis angles intraoperatively resulted in almost the same values as measurements in standing plane radiographs postoperatively, despite prone position. These findings could especially be shown for the level L4-S1. The intraobserver reliability was almost perfect for both, intra- and postoperative measurements. In conclusion, the intraoperative measurement of a lumbar lordosis angle can perfectly predict the postoperative result
MR-arterioportography: A new technical approach for detection of liver lesions
AIM: To evaluate the benefit and effectiveness of MR-arterioportography (MR-AP) to achieve the highest sensitivity for detection and evaluation of hepatocellular carcinoma (HCC)