4 research outputs found

    Percutaneous Management of Pyogenic Hepatic Abscesses

    Get PDF
    Twelve patients (9 men, 3 women) with a mean age of 65 (54-78) years, with pyogenic hepatic abscesses were managed by percutaneous drainage between 1979 and 1987. Biliary origin was most common (4 patients), followed by hepatic abscesses as a late postoperative complication (seen in 3 patients) and hepatic abscesses occurring in association with acute appendicitis (2 patients). The origin was unknown in 3 patients. Diagnosis was reached by computed tomography or ultrasonography with a diagnostic delay of in mean 11 days. Seventeen abscesses were found among the 12 patients. The median abscess size (maximal diameter) was 7 (1-12) cm. Nine patients were treated with percutaneous drainage with an indwelling catheter within the abscess cavity for up to 3 weeks, while 3 patients were managed with percutaneous puncture and aspiration alone. The most commonly isolated organism from the drained hepatic abscess was E. coli. The course following percutaneous treatment was uneventful, without mortality and recurrence of the hepatic abscess during follow-up. One patient required surgical drainage of an additional hepatic abscess. Percutaneous drainage of hepatic abscesses, independent of origin, thus seems as a safe and reliable method, which should be considered as the treatment of choice if facilities and knowledge of percutaneous management are provided

    Phantom study of chest radiography with storage phosphor, selenium, and film-screen systems

    No full text
    Purpose: Chest radiographs from 3 digital systems - 2 based on luminescent phosphors and one on selenium - and a conventional film-screen system were evaluated and compared. Material and Methods: Computed radiography (CR) has for the past years been dominated by a single manufacturer, but now several systems have been marketed. Using a chest phantom and, as test objects, 2 simulated tumours for the lung and mediastinum, respectively, and one object simulating pulmonary lines, a total of 400 exposures were made, 100 on each system. The test objects were placed randomly with a ratio of presence/absence of each object of about 50. Six radiologists participated, 2 residents and 4 staff members. A receiver operating characteristics (ROC) analysis was performed with construction of curves, and the difference between the curves was estimated with a 2-tailed paired t-test. Results and Conclusion: The selenium-based system performed significantly better for pulmonary line detection than all the other systems, and better than one storage phosphor system for the lung "tumour" (p<0.05), while one storage phosphor system was slightly better than the other in diagnosing all 3 test objects. The score for the film-screen system was only average
    corecore