645 research outputs found

    Use of signal sequences as an in situ removable sequence element to stimulate protein synthesis in cell-free extracts

    Get PDF
    This study developed a method to boost the expression of recombinant proteins in a cell-free protein synthesis system without leaving additional amino acid residues. It was found that the nucleotide sequences of the signal peptides serve as an efficient downstream box to stimulate protein synthesis when they were fused upstream of the target genes. The extent of stimulation was critically affected by the identity of the second codons of the signal sequences. Moreover, the yield of the synthesized protein was enhanced by as much as 10 times in the presence of an optimal second codon. The signal peptides were in situ cleaved and the target proteins were produced in their native sizes by carrying out the cell-free synthesis reactions in the presence of Triton X-100, most likely through the activation of signal peptidase in the S30 extract. The amplification of the template DNA and the addition of the signal sequences were accomplished by PCR. Hence, elevated levels of recombinant proteins were generated within several hours

    Evaluation of three glucometers for whole blood glucose measurements at the point of care in preterm or low-birth-weight infants

    Get PDF
    PurposeWe evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants.MethodsBetween December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.).ResultsThe correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels≤60 mg/dL, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment , after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ≤60 mg/dL), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively.ConclusionSignificant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults

    Impact of Body Mass Index on the relationship of epicardial adipose tissue to metabolic syndrome and coronary artery disease in an Asian population

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In a previous study, we demonstrated that the thickness of epicardial adipose tissue (EAT), measured by echocardiography, was increased in patients with metabolic syndrome (MS) and coronary artery disease (CAD). Several studies on obese patients, however, failed to demonstrate any relationship between EAT and CAD. We hypothesized that body mass index (BMI) affected the link between EAT and MS and CAD.</p> <p>Methods</p> <p>We consecutively enrolled 643 patients (302 males, 341 females; 59 ± 11 years), who underwent echocardiography and coronary angiography. The EAT thickness was measured on the free wall of the right ventricle at the end of diastole. All patients were divided into two groups: high BMI group, ≥27 kg/m<sup>2 </sup>(n = 165), and non-high BMI group, < 27 kg/m<sup>2 </sup>(n = 478).</p> <p>Results</p> <p>The median and mean EAT thickness of 643 patients were 3.0 mm and 3.1 ± 2.4 mm, respectively. In the non-high BMI group, the median EAT thickness was significantly increased in patients with MS compared to those without MS (3.5 vs. 1.9 mm, p < 0.001). In the high BMI group, however, there was no significant difference in the median EAT thickness between patients with and without MS (3.0 vs. 2.5 mm, p = 0.813). A receiver operating characteristic (ROC) curve analysis predicting MS revealed that the area under the curve (AUC) of the non-high BMI group was significantly larger than that of the high BMI group (0.659 vs. 0.506, p = 0.007). When compared to patients without CAD, patients with CAD in both the non-high and high BMI groups had a significantly higher median EAT thickness (3.5 vs. 1.5 mm, p < 0.001 and 4.0 vs. 2.5 mm, p = 0.001, respectively). However, an ROC curve analysis predicting CAD revealed that the AUC of the non-high BMI group tended to be larger than that of the high BMI group (0.735 vs. 0.657, p = 0.055).</p> <p>Conclusions</p> <p>While EAT thickness was significantly increased in patients with MS and CAD, the power of EAT thickness to predict MS and CAD was stronger in patients with BMI < 27 kg/m<sup>2</sup>. These findings showed that the measurement of EAT thickness by echocardiography might be especially useful in an Asian population with a non-high BMI, less than 27 kg/m<sup>2</sup>.</p

    Dense Iron Ejecta and Core-collapse Supernova Explosion in the Young Supernova Remnant G11.2-0.3

    Get PDF
    We present the results of near-infrared spectroscopic observations of dense (\simgt 103^3 cm3^{-3}) iron ejecta in the young core-collapse supernova remnant G11.2-0.3. Five ejecta knots projected to be close to its center show a large dispersion in their Doppler shifts: two knots in the east are blueshifted by more than 1,000 \kms, while three western knots have relatively small blueshifts of 20-60 \kms. This velocity discrepancy may indicate that the western knots have been significantly decelerated or that there exists a systematic velocity difference among the knots. One ejecta filament in the northwestern boundary, on the other hand, is redshifted by \simgt 200 \kms, while opposite filament in the southeastern boundary shows a negligible radial motion. Some of the knots and filaments have secondary velocity components, and one knot shows a bow shock-like feature in the velocity structure. The iron ejecta appear to be devoid of strong emission from other heavy elements, such as S, which may attest to the alpha-rich freezeout process in the explosive nucleosynthesis of the core-collapse supernova explosion close to its center. The prominent bipolar distribution of the Fe ejecta in the northwestern and southeastern direction, along with the elongation of the central pulsar wind nebula in the perpendicular direction, is consistent with the interpretation that the supernova exploded primarily along the northwestern and southeastern direction.Comment: To appear in ApJ Letter

    Sustainable and recyclable super engineering thermoplastic from biorenewable monomer

    Get PDF
    Environmental and health concerns force the search for sustainable super engineering plastics (SEPs) that utilise bio-derived cyclic monomers, e.g. isosorbide instead of restricted petrochemicals. However, previously reported bio-derived thermosets or thermoplastics rarely offer thermal/mechanical properties, scalability, or recycling that match those of petrochemical SEPs. Here we use a phase transfer catalyst to synthesise an isosorbide-based polymer with a high molecular weight >100 kg mol−1, which is reproducible at a 1-kg-scale production. It is transparent and solvent/melt-processible for recycling, with a glass transition temperature of 212 °C, a tensile strength of 78 MPa, and a thermal expansion coefficient of 23.8 ppm K−1. Such a performance combination has not been reported before for bio-based thermoplastics, petrochemical SEPs, or thermosets. Interestingly, quantum chemical simulations show the alicyclic bicyclic ring structure of isosorbide imposes stronger geometric restraint to polymer chain than the aromatic group of bisphenol-A.11Ysciescopu
    corecore