8 research outputs found

    Surgical outcome comparisons of multifocal IOLs of Lentis Comfort LS-313 MF15 and Tecnis Eyhance DIB00V

    Get PDF
    AIM: To compare the surgical outcomes of a multifocal intraocular lens (IOL; Lentis Comfort LS-313 MF15) with those of an enhanced monofocal IOL (Tecnis Eyhance DIB00V). METHODS: This retrospective study included patients who underwent cataract surgery with LS-313 MF15 or Eyhance IOL implantation. Data regarding patient demographics, surgical records, and ophthalmic examination before the cataract surgery and one and three months postoperatively were collected. Visual acuities, refractive values, defocus curves, contrast sensitivities and subjective symptoms were evaluated. RESULTS: Among the 71 eyes (47 patients) included in this study, 32 eyes (20 patients) underwent LS-313 MF15 IOL implantation, and 39 eyes (27 patients) underwent Eyhance IOL implantation. No significant differences were observed in age, axial length, or refractive error between the two groups preoperatively. Furthermore, the distance-corrected and uncorrected distance visual acuities one month postoperatively did not differ between the groups, and both groups had sufficient visual acuities at the distances of 5, 1 m, 70, 50, and 30 cm. Other ophthalmic data, including subjective symptoms based on the 14-item Visual Function Index Questionnaire, monocular defocus curves, contrast sensitivities, and halo and glare, did not differ between the groups three months postoperatively. Moreover, both groups had good outcomes. The spherical equivalent one month postoperatively was significantly myopic in the LS-313 MF15 group compared with that in the Eyhance group (P=0.033); however, this difference was not observed three months postoperatively (P=0.471). CONCLUSION: Comparison of the surgical outcomes of LS-313 MF15 with those of Eyhance with different optical properties reveal that both IOLs show good postoperative outcomes, with no significant differences being noted between the two IOLs

    Association between Combined Structure Function Index and Glaucoma Severity

    No full text
    The aim of this study was to investigate the relationship between combined structure function index (CSFI) and standard automated perimetry (SAP) parameters such as mean deviation (MD) and visual field index (VFI) in open-angle glaucoma (OAG). We retrospectively reviewed medical records from September 2009 to July 2015, which included 195 eyes of 195 patients with OAG or normal-tension glaucoma who underwent SAP and optical coherence tomography on the same day (male: female, 128 : 67; mean age, 61.4 ± 11.3 years; mean spherical equivalent, −2.39 ± 2.3 D). We divided participants into three stages based on MD value: early, MD > −6 dB; middle, −6 dB ≥ MD ≥ −12 dB; and advanced, MD < 12 dB. We then evaluated correlations between CSFI and SAP parameters in each stage using Pearson’s correlation coefficient. Mean CSFI (%), mean MD (dB), and VFI (%) in each stage were early (22.4, −2.13, and 94.0); middle (47.9, −8.78, and 75.4); and advanced (68.3, −17.32, and 49.0), respectively. Correlations between CSFI and whole, early, middle, and advanced MD were −0.88 (p<0.001), −0.68, −0.24, and −0.76, respectively. Correlations between CSFI and whole, early, middle, and advanced VFI were −0.86 (p<0.001), −0.59, −0.20, and −0.83, respectively. Consistency between CSFI and SAP indices in middle-stage glaucoma was low
    corecore