3 research outputs found

    New evidence of arsenic translocation and accumulation in Pteris vittata from real‐time imaging using positron‐emitting 74As tracer

    No full text
    Pteris vittata is an arsenic (As) hyperaccumulator plant that accumulates a large amount of As into fronds and rhizomes (around 16,000 mg/kg in both after 16 weeks hydroponic cultivation with 30 mg/L arsenate). However, the sequence of long‐distance transport of As in this hyperaccumulator plant is unclear. In this study, we used a positron‐emitting tracer imaging system (PETIS) for the first time to obtain noninvasive serial images of As behavior in living plants with positron‐emitting 74As‐labeled tracer. We found that As kept accumulating in rhizomes as in fronds of P. vittata, whereas As was retained in roots of a non‐accumulator plant Arabidopsis thaliana. Autoradiograph results of As distribution in P. vittata showed that with low As exposure, As was predominantly accumulated in young fronds and the midrib and rachis of mature fronds. Under high As exposure, As accumulation shifted from young fronds to mature fronds, especially in the margin of pinna, which resulted in necrotic symptoms, turning the marginal color to gray and then brown. Our results indicated that the function of rhizomes in P. vittata was As accumulation and the regulation of As translocation to the mature fronds to protect the young fronds under high As exposure

    Non-invasive imaging of radiocesium dynamics in a living animal using a positron-emitting 127Cs tracer

    No full text
    Visualizing the dynamics of cesium (Cs) is desirable to understand the impact of radiocesium when accidentally ingested or inhaled by humans. However, visualization of radiocesium in vivo is currently limited to plants. Herein, we describe a method for the production and purification of 127Cs and its use in visualizing Cs dynamics in a living animal. The positron-emitting nuclide 127Cs was produced using the 127I (α, 4n) 127Cs reaction, which was induced by irradiation of sodium iodide with a 4He2+ beam from a cyclotron. We excluded sodium ions by using a material that specifically adsorbs Cs as a purification column and successfully eluted 127Cs by flowing a solution of ammonium sulfate into the column. We injected the purified 127Cs tracer solution into living rats and the dynamics of Cs were visualized using positron emission tomography; the distributional images showed the same tendency as the results of previous studies using disruptive methods. Thus, this method is useful for the non-invasive investigation of radiocesium in a living animal
    corecore