120 research outputs found

    Effects of nuclear orientation on fusion and fission in the reaction using 238U target nucleus

    Get PDF
    Fission fragment mass distributions in the reaction of 30Si+238U were measured around the Coulomb barrier. At the above-barrier energies, the mass distribution showed a Gaussian shape. At the subbarrier energies, triple-humped distribution was observed, which consists of symmetric fission and asymmetric fission peaked at AL/AH ~ 90/178. The asymmetric fission should be attributed to quasifission from the results of the measured evaporation residue (ER) cross-sections for 30Si+238U. The cross-section for 263Sg at the abovebarrier energy agree with the statistical model calculation which assumes that the measured fission cross-section originates from fusion-fission, whereas the one for 264 Sg measured at the sub-barrier energy is smaller than the calculation, which suggests the presence of quasifission

    A novel digital PID controlled dc-dc converter

    Get PDF
    This paper presents the relationship between the dynamic characteristics and sampling frequency of digitally controlled dc-dc converter with a novel control method. In the proposed method, the calculation process of P and I-D controls is parallel. The sampling interval and points for I-D control are same to the conventional method. However, the sampling point for P control is quickly. The A-D converter can sample the output voltage during the short interval because the calculation process of P control is very simple and to important for transient response. The only sample data near the turn-off timing of PWM pulse is used. The simulation and experiment results of the output voltage against the step change of the load and changing the P control sampling frequency are discussed. As a result, it is revealed experimentally that the good transient response is obtained.2010 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM 2010) : Pisa, Italy, 2010.06.14-2010.06.1

    Preclinical Evaluation of Biodistribution and Toxicity of [211At]PSMA-5 in Mice and Primates for the Targeted Alpha Therapy against Prostate Cancer

    Get PDF
    Watabe T., Kaneda-Nakashima K., Kadonaga Y., et al. Preclinical Evaluation of Biodistribution and Toxicity of [211At]PSMA-5 in Mice and Primates for the Targeted Alpha Therapy against Prostate Cancer. International Journal of Molecular Sciences 25, 5667 (2024); https://doi.org/10.3390/ijms25115667.Astatine (211At) is a cyclotron-produced alpha emitter with a physical half-life of 7.2 h. In our previous study, the 211At-labeled prostate-specific membrane antigen (PSMA) compound ([211At]PSMA-5) exhibited excellent tumor growth suppression in a xenograft model. We conducted preclinical biodistribution and toxicity studies for the first-in-human clinical trial. [211At]PSMA-5 was administered to both normal male ICR mice (n = 85) and cynomolgus monkeys (n = 2). The mice were divided into four groups for the toxicity study: 5 MBq/kg, 12 MBq/kg, 35 MBq/kg, and vehicle control, with follow-ups at 1 day (n = 10 per group) and 14 days (n = 5 per group). Monkeys were observed 24 h post-administration of [211At]PSMA-5 (9 MBq/kg). Blood tests and histopathological examinations were performed at the end of the observation period. Blood tests in mice indicated no significant myelosuppression or renal dysfunction. However, the monkeys displayed mild leukopenia 24 h post-administration. Despite the high accumulation in the kidneys and thyroid, histological analysis revealed no abnormalities. On day 1, dose-dependent single-cell necrosis/apoptosis was observed in the salivary glands of mice and intestinal tracts of both mice and monkeys. Additionally, tingible body macrophages in the spleen and lymph nodes indicated phagocytosis of apoptotic B lymphocytes. Cortical lymphopenia (2/10) in the thymus and a decrease in the bone marrow cells (9/10) were observed in the 35 MBq/kg group in mice. These changes were transient, with no irreversible toxicity observed in mice 14 days post-administration. This study identified no severe toxicities associated with [211At]PSMA-5, highlighting its potential as a next-generation targeted alpha therapy for prostate cancer. The sustainable production of 211At using a cyclotron supports its applicability for clinical use

    Chemical Characterization of a Volatile Dubnium Compound, DbOCl3

    Get PDF
    The formation and the chemical characterization of single atoms of dubnium (Db, element 105), in the form of its volatile oxychloride, was investigated using the on-line gas phase chromatography technique, in the temperature range 350–600 °C. Under the exactly same chemical conditions, comparative studies with the lighter homologues of Group 5 in the Periodic Table clearly indicate the volatility sequence being NbOCl3 > TaOCl3 ≥ DbOCl3. From the obtained experimental results, thermochemical data for DbOCl3 were derived. The present study delivers reliable experimental information for theoretical calculations on chemical properties of transactinides

    フクブ ドンテキ ガイショウゴ チハツセイ ニ ショウジタ オウコウ ケッチョウ カンマク レッコウ ヘルニア ノ 1レイ

    Get PDF
    A 77-year-old woman presented to the emergency department with complains of abdominal pain and frequent vomiting. In the past, she has never been on surgery but she suffered blunt liver injury after motor vehicle accident nine months ago. She was performed trans-catheter arterial embolization to the left hepatic lobe at that time and had been seeing a doctor regularly for post traumatic biloma. The contrast-enhanced abdominal CT scan revealed a closed loop and a dilatation of a small intestine. She was diagnosed a small bowel obstruction due to a internal hernia. She was operated urgently. The surgical exploration showed that the congested jejunum incarcerated into an omental bursa, and an adhesion of the jejunum mesentery and a greater omentum. We found a mesentery hiatus of the transverse colon, through which a higher jejunum had incarcerated into the omental bursa. The jejunum was reduced manually and the hiatus was closed by suture. The patient followed a favorable postoperative course and was discharged on postoperative day6. We report a extremely rare transverse colon hiatal hernia that occurred in the late onset after blunt abdominal injury with the review of the literature

    Study of fission using multi-nucleon transfer reactions

    Get PDF
    Multi-nucleon transfer channels of the reactions of 18O+232Th, 18O+238U, 18O+248Cm were used to measure fission-fragment mass distribution for various nuclides and their excitation energy dependence. Predominantly asymmetric fission is observed at low excitation energies for all the studied cases, with an increase of the symmetric fission towards high excitation energies. Experimental data are compared with predictions of the fluctuation-dissipation model, where effects of multi-chance fission (neutron evaporation prior to fission) was introduced. It was shown that a reliable understanding of the observed fission fragment mass distributions can be obtained only invoking multi-chance fissions

    The ASTRO-H X-ray Observatory

    Full text link
    The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the high-energy universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV. These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3-2 keV with high spectral resolution of Delta E < 7 eV, enabled by a micro-calorimeter array located in the focal plane of thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5-80 keV, located in the focal plane of multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4-12 keV, with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera type soft gamma-ray detector, sensitive in the 40-600 keV band. The simultaneous broad bandpass, coupled with high spectral resolution, will enable the pursuit of a wide variety of important science themes.Comment: 22 pages, 17 figures, Proceedings of the SPIE Astronomical Instrumentation "Space Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray

    Hitomi (ASTRO-H) X-ray Astronomy Satellite

    Get PDF
    The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E  >  2  keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month
    corecore