54 research outputs found
Esophageal Capsule Endoscopy for Screening Esophageal Varices among Japanese Patients with Liver Cirrhosis
Purpose. Although esophageal capsule endoscopy (ECE) is reportedly useful in the diagnosis of esophageal varices (EV), few reports have described the benefits of this technique in Asian countries. The present paper evaluates the usefulness of ECE for diagnosing EV in Japanese patients with cirrhosis.
Methods. We examined 29 patients with cirrhosis (20 males and 9 females; mean age 60 years; Child-Pugh classification A/B/C; 14/14/1) using ECE followed by esophagogastroduodenoscopy (EGD). High-risk EV were defined as F2 and/or RC2 and above. Results. The sensitivity and specificity of ECE for the diagnosis of high-risk EV were 92% and 80%, respectively. Conclusions. The findings showed that ECE is a highly sensitive method of diagnosing high-risk EV that requires endoscopic or pharmacological therapy. Thus, ECE might be a useful method for the screening and followup of EV in patients with cirrhosis
Correlations between oxygen octahedral distortions and magnetic and transport properties in strained La0.5Sr0.5CoO3 thin films
Simulations of Surface X-ray Diffraction from a Monolayer 4He Film Adsorbed on Graphite
We carried out simulations of crystal truncation rod (CTR) scatterings, i.e.,
one of the surface X-ray diffraction techniques with atomic resolution, from a
monolayer He film adsorbed on graphite. Our simulations reveal that the 00L rod
scatterings from the He monolayer exhibit notable intensity modifications for
those from a graphite surface in the ranges of approximately L = 0.6 - 1.7 and
L = 2.2 - 3.5. The height of the He monolayer from the graphite surface largely
affects the CTR scattering profiles, indicating that CTR scatterings have
enough sensitivities to determine the surface structure of the various phases
in the He layer. In particular, in the incommensurate solid phase, our
preliminary experimental data show the intensity modulations that are expected
from the present simulations.Comment: 6 pages, 4 figures, to be published in JPS Conf. Pro
A Prospective Comparison of EUS-Guided FNA Using 25-Gauge and 22-Gauge Needles
Background and Aims. There are limited data on the differences in diagnostic yield between 25-gauge and 22-gauge EUS-FNA needles. This prospective study compared the difference in diagnostic yield between a 22-gauge and a 25-gauge needle when performing EUS-FNA. Methods. Forty-three patients with intraluminal or extraluminal mass lesions and/or lymphadenopathy were enrolled prospectively. EUS-FNA was performed for each mass lesion using both 25- and 22-gauge needles. The differences in accuracy rate, scoring of needle visibility, ease of puncture and quantity of obtained specimen were evaluated. Results. The overall accuracy of 22- and 25-gauge needle was similar at 81% and 76% respectively (N.S). Likewise the visibility scores of both needles were also similar. Overall the quantity of specimen obtained higher with the 22-gauge needle (score: 1.64 vs. P < .001). However the 25-gauge needle was significantly superior to the 22-gauge needle in terms of ease of puncture (score: 1.9 vs. 1.29, P < .001) and in the quantity of specimen in the context of pancreatic mass EUS-FNA (score: 1.8 vs. 1.58, P < .05). Conclusion. The 22-gauge and 25-gauge needles have similar overall diagnostic yield. The 25-gauge needle appeared superior in the subset of patients with hard lesions and pancreatic masses
Phase Transition and Crystal Structure of the Si(111)-.RAD.3*.RAD.3-Ag Surface Studied by X-ray Diffraction
Enhanced Harmonic Endoscopic Ultrasonography for Assessment of Pancreaticobiliary Malignancies
- …