85 research outputs found
Recommended from our members
High Performance Quantum Cascade Lasers Based on Three-Phononresonance Design
A quantum cascade laser structure based on three-phonon-resonance design is proposed and demonstrated. Devices, emitting at a wavelength of 9 μm, processed into buried ridge waveguide structures with a 3 mm long, 16 μm wide cavity and a high-reflection (HR) coating have shown peak output powers of 1.2 W, slope efficiencies of 1 W/A, threshold current densities of 1.1 kA/cm2, and high wall-plug efficiency of 6% at 300 K. A 3 mm long, 12 μm wide buried-heterostructure device without a HR coating exhibited continuous wave output power of as high as 65 mW from a single facet at 300 K.Engineering and Applied Science
Semiconductor Lasers With Integrated Plasmonic Polarizers
The authors reported the plasmonic control of semiconductor laser polarization by means of metallic gratings and subwavelength apertures patterned on the laser emission facet. An integrated plasmonic polarizer can project the polarization of a semiconductor laser onto other directions. By designing a facet with two orthogonal grating-aperture structures, a polarization state consisting of a superposition of a linearly and right-circularly polarized light was demonstrated in a quantum cascade laser; a first step toward a circularly polarized laser.Engineering and Applied Science
Spectral responses of GaAs photodiodes fabiricated by rapid thermal diffusion
The spectral responses of GaAs photodiodes fabricated by rapid thermal diffusion (RTD) of Zn are presented. The authors tried controlling the p+-n junction depth by the heating rate of RTD, without extending the diffusion time. It is found that Zn diffuses from the surface to a deeper position as the heating rate increases. Consequently, the spectral response of photodiodes formed by RTD is strongly dependent on the heating rate of RTD. A large improvement in the short-wavelength response between 400 and 800 nm is observed as the heating rate decreases
Recommended from our members
Deformed Microcavity Quantum Cascade Lasers with Directional Emission
We report the experimental realization of deformed microcavity quantum cascade lasers (QCLs) with a Limaçon-shaped chaotic resonator. Directional light emission with a beam divergence of from QCLs emitting at λ ≈ 10µm was obtained in the plane of the cavity for deformations in the range 0.37 < ε < 0.43. An excellent agreement between measured and calculated far-field profiles was found. Both simulations and experiments show that the Limaçon-shaped microcavity preserves whispering gallery-like modes with high Q-factors for low deformations (ε < 0.50). In addition, while the measured spectra show a transition from whispering gallery-like modes to a more complex mode structure at higher pumping currents, we observed ‘universal far-field behavior’ for different intracavity mode distributions in the Limaçon microcavity, which can be explained by the distribution of unstable manifolds in ray optics simulations. Furthermore, the performance of the deformed microcavity lasers is robust with respect to variations of the deformation near its optimum value ε = 0.40, which implies that this structure reduces the requirements on photolithography fabrication. The successful realization of these microcavity lasers may lead to applications in optoelectronics.Engineering and Applied Science
Recommended from our members
Directional Emission and Universal Far-Field Behavior from Semiconductor Lasers with Limacon-Shaped Microcavity
We report experimental demonstration of directional light emission from limaçon-shaped microcavity semiconductor lasers. Quantum cascade lasers (QCLs) emitting at are used as a model system. Both ray optics and wave simulations show that for deformations in the range , these microcavities support high quality-factor whispering gallerylike modes while having a directional far-field profile with a beam divergence in the plane of the cavity. The measured far-field profiles are in good agreement with simulations. While the measured spectra show a transition from whispering gallerylike modes to a more complex mode structure at higher pumping currents, the far field is insensitive to the pumping current demonstrating the predicted “universal far-field behavior” of this class of chaotic resonators. Due to their relatively high quality factor, our microcavity lasers display reduced threshold current densities compared to conventional ridge lasers with millimeter-long cavities. The performance of the limaçon-shaped QCLs is robust with respect to variations of the deformation near its optimum value of .Engineering and Applied Science
Recommended from our members
Multi-Beam Multi-Wavelength Semiconductor Lasers
Multibeam emission and spatial wavelength demultiplexing in semiconductor lasers by patterning their facets with plasmonic structures is reported. Specifically, a single-wavelength laser was made to emit beams in two directions by defining on its facet two metallic gratings with different periods. The output of a dual-color laser was spatially separated according to wavelength by using a single metallic grating. The designs can be integrated with a broad range of active or passive optical components for applications such as interferometry and demultiplexing.Physic
Impact of glycemic control with sitagliptin on the 2‑year progression of arterial stiffness : a sub‑analysis of the PROLOGUE study
Background: No conclusive evidence has been obtained yet on the significance of the effects of dipeptidyl peptidase-4 (DPP-4 inhibitor) treatment on the arterial stiffness in clinical settings. In addition, the effects of good glycemic control on the arterial stiffness have also not been clarified yet. As a sub-analysis of the PROLOGUE study, we examined the effect of a DPP-4 inhibitor (sitagliptin) on the 2-year progression of the arterial stiffness and also to determine the effect of good glycemic control on the rate of progression of the arterial stiffness.
Methods: In the PROLOGUE study, the study participants were either allocated to add-on sitagliptin treatment or to continued treatment with conventional anti-diabetic agents. Among the 463 participants of the PROLOGUE study, we succeeded in measuring the brachial-ankle pulse wave velocity (baPWV) at least two times during the 2-year study period in 96 subjects.
Results: The changes in the baPWV during the study period were similar between the both groups (i.e., with/without staglipitin), overall. On the other hand, when the study subjects were divided into two groups according to the glycemic control status during the study period {good glycemic control group (GC) = hemoglobin (Hb)A1c <7.0 at both 12 and 24 months after the treatment randomization; poor glycemic control group (PC) = HbA1c ≥7.0 at either 12 months, 24 months, or both}, the 2-year increase of the baPWV was marginally significantly larger in the PC group (144 ± 235 cm/s) as compared to that the GC group (−10 ± 282 cm/s) (p = 0.036).
Conclusion: While the present study could not confirm the beneficial effect of sitagliptin per se on the arterial stiffness, the results suggested that good glycemic control appears to be beneficial for delaying the annual progression of the arterial stiffness
A propensity score matching study on robot-assisted radical cystectomy for older patients : comparison of intracorporeal ileal conduit and cutaneous ureterostomy
Background: Robot-assisted radical cystectomy (RARC) and intracorporeal urinary diversion are less invasive than conventional procedures. However, for older patients, cutaneous ureterostomy (CUS) may be preferred because urinary diversion using the intestine has a high incidence of perioperative complications and is highly invasive. The purpose of this study was to demonstrate the safety and efficacy of intracorporeal ileal conduit (ICIC) compared with CUS in patients aged 75 years or older who underwent RARC.
Methods: From October 2014 to December 2021, 82 patients aged 75 years or older who underwent RARC at Tokushima University Hospital, Tokushima Prefectural Central Hospital, or Ehime Prefectural Central Hospital were retrospectively reviewed. Of these, 52 and 25 patients who underwent ICIC and CUS, respectively, were included. After adjusting the patients’ characteristics using propensity score-matching, surgical results and prognoses were retrospectively compared. The propensity score was based on age, Eastern Cooperative Oncology Group Performance Status Scale (ECOG-PS), American Society of Anesthesiologists physical status classification (ASA-PS), clinical tumor stage, and neoadjuvant chemotherapy.
Results: The median age was lower in the ICIC group compared with the CUS group, and the proportion of high-risk cases (ECOG-PS ≥ 2 or ASA-PS ≥ 3) did not differ. The median operation time was longer in the ICIC group, and estimated blood loss was higher, compared with the CUS group. There were no significant differences in the incidence of complications within the first 30 postoperative days, incidence of complications 30–90 days after surgery, 2 year overall survival, 2-year cancer-specific survival, and 2-year recurrence-free survival. The stent-free rate was significantly lower in the CUS group than that in the ICIC group.
Conclusion: In older patients, the ICIC group showed non-inferior surgical and oncological outcomes compared with the CUS group. Urinary diversion following RARC in older patients should be carefully selected by considering not only the age but also the general condition (including comorbidities) of the patient
- …